WINTACT WT319A WT319B

WINTACT WT319A / WT319B Infrared Thermometer Instruction Manual

Models: WT319A, WT319B

1. Introduction

The WINTACT WT319A and WT319B are non-contact infrared thermometers designed for safe and quick temperature measurements. These handheld devices are ideal for a wide range of applications including industrial settings, baking, air conditioning, refrigeration, and general heating and cooling systems. They provide accurate readings without direct contact, making them suitable for measuring hot, hazardous, or hard-to-reach surfaces.

WINTACT WT319A Infrared Thermometer
WINTACT WT319A Infrared Thermometer with -50℃~400℃ range.
WINTACT WT319B Infrared Thermometer
WINTACT WT319B Infrared Thermometer with -50℃~550℃ range.

2. Safety Information

Please read and understand all safety information before using this product.

  • Laser Safety: This device uses a Class 2 laser product. Do not stare directly into the laser beam or point it at eyes. Avoid direct eye exposure.
  • Reflective Surfaces: Do not point the laser at highly reflective surfaces, as reflected laser light can also cause eye damage.
  • Not for Medical Use: This thermometer is designed for industrial and household use, not for measuring human body temperature.
  • Children: Keep the device out of reach of children.
  • Maintenance: Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.

3. Product Overview

The WINTACT infrared thermometer features an ergonomic design for comfortable handling, a clear backlit LCD display, and intuitive controls.

3.1 Key Features

  • Laser Positioning for accurate targeting.
  • Quick Measurement response time.
  • Temperature Unit Conversion (Celsius/Fahrenheit).
  • Distance to Spot Size (D:S) ratio for optimal measurement.
  • Low Temperature Alarm (rephrased from 'LOW TEMPERATURE CALL THE POLICE').
  • Backlit Display for visibility in various lighting conditions.
  • Automatic Data Hold function.
  • Auto Power Off to conserve battery life.
Feature icons for WINTACT thermometer
Visual representation of key features.

3.2 Device Components and LCD Display

Familiarize yourself with the device's layout and display icons:

LCD Display Function Description
Detailed view of the LCD display and button functions.
  • Temperature Reading: Displays the measured temperature.
  • Scanning Icon: Indicates active measurement.
  • Data Hold Icon (HOLD): Appears when the reading is held on screen.
  • Low Battery Icon: Indicates batteries need replacement.
  • Fahrenheit Unit (℉) / Celsius Unit (℃): Shows the selected temperature unit.
  • Backlight On Icon: Indicates the display backlight is active.
  • Laser On Icon: Indicates the laser pointer is active.
  • Laser On/Off Button: Toggles the laser pointer.
  • Backlight On/Off Button: Toggles the display backlight.
  • Celsius/Fahrenheit Switch Button (℃/℉): Changes the temperature unit.
  • Trigger: Activates measurement and laser.
Ergonomic design and clear backlit screen
The thermometer features an ergonomic design for comfortable grip and a clear backlit screen.

4. Setup

4.1 Battery Installation

The WINTACT infrared thermometer requires two 1.5V AAA batteries for operation.

  1. Locate the battery compartment on the handle of the device.
  2. Gently pull down the handle cover to open the battery compartment.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+/-).
  4. Close the handle cover until it clicks securely into place.
Battery installation diagram
Diagram illustrating how to open the handle for battery installation.

5. Operating Instructions

5.1 Taking a Measurement

  1. Point the thermometer at the target object.
  2. Pull and hold the trigger. The laser pointer will activate (if enabled) to help aim. The 'SCAN' icon will appear on the display.
  3. The measured temperature will be displayed on the LCD screen.
  4. Release the trigger. The 'HOLD' icon will appear, and the last measured temperature will remain on the display for a few seconds before the device automatically powers off (if auto power off is enabled).
Laser positioning in use
The laser pointer assists in precisely targeting the measurement area.

5.2 Unit Conversion (℃/℉)

Press the '℃/℉' button located below the display to switch between Celsius and Fahrenheit temperature units.

5.3 Laser and Backlight Control

Use the dedicated buttons below the display to toggle the laser pointer and the display backlight on or off as needed for your measurement environment.

5.4 Distance to Spot Size (D:S)

The D:S ratio for this thermometer is 12:1. This means that at a distance of 12 inches from the target, the measurement spot diameter will be 1 inch. To ensure accurate readings, make sure the target area is larger than the spot size at your chosen measurement distance.

6. Maintenance

6.1 Cleaning

  • Lens: The most critical part of the thermometer is the lens. Clean it with a soft, damp cloth or cotton swab. Do not use abrasive cleaners or solvents.
  • Casing: Clean the device casing with a damp cloth and mild soap. Do not immerse the device in water.

6.2 Storage

  • Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Remove batteries if the device will not be used for an extended period to prevent leakage.

7. Troubleshooting

ProblemPossible CauseSolution
Display shows "Hi" or "Lo"Temperature is outside the measurement range.Ensure the target temperature is within the specified range for your model (WT319A: -50℃~400℃; WT319B: -50℃~550℃).
Blank displayLow or dead batteries.Replace with fresh 1.5V AAA batteries.
Inaccurate readings
  • Lens is dirty.
  • Target is too small or too far.
  • Measuring through glass or shiny metal.
  • Thermometer not acclimated to ambient temperature.
  • Clean the lens.
  • Ensure target is larger than the spot size (12:1 D:S ratio).
  • Avoid measuring through reflective surfaces.
  • Allow 20-30 minutes for the thermometer to adjust to ambient temperature before use.

8. Specifications

ParameterWT319AWT319B
Measuring Range-50℃~400℃ (-58℉~752℉)-50℃~550℃ (-58℉~1022℉)
AccuracyΒ±1.5℃ or Β±1.5% (whichever is greater)
Resolution0.1℃ or 0.1℉
Response Time500ms (0.5s)
Emissivity0.95 (fixed)
Distance to Spot Size Ratio (D:S)12:1
Power Supply2 x 1.5V AAA Batteries
Auto Power OffYes
BacklightYes
Laser Target PointerYes
Unit Conversion℃/℉
TypeHandheld Infrared Thermometer

9. User Tips

  • For optimal accuracy, ensure the target object completely fills the measurement spot size.
  • Regularly clean the infrared lens to prevent dust or debris from affecting readings.
  • When measuring liquids, stir the liquid to ensure a uniform temperature for a more accurate reading.
  • Be aware that shiny or polished metal surfaces may give lower readings due to their low emissivity. For such surfaces, you might apply a piece of masking tape or flat black paint to the surface and measure the temperature of the treated spot.

10. Warranty and Support

For warranty information, technical support, or service inquiries, please contact the retailer or manufacturer directly. Keep your purchase receipt as proof of purchase.

Related Documents - WT319A WT319B

Preview Wintact WT3652 Non-Contact Infrared Thermometer User Manual
Comprehensive guide to operating the Wintact WT3652 non-contact infrared thermometer, including features, LCD display, operation instructions, technical parameters, and precautions for accurate temperature measurement.
Preview Wintact WT320 Infrared Thermometer Instruction Manual
Comprehensive guide to operating and maintaining the Wintact WT320 Infrared Thermometer, covering features, safety precautions, specifications, and usage instructions.
Preview Wintact WT323C Infrared Thermometer User Manual
User manual for the Wintact WT323C Infrared Thermometer, detailing its features, operation, specifications, and maintenance.
Preview WINTACT WT9055 Digital Sound Level Meter: User Manual & Technical Specifications
Detailed instruction manual for the WINTACT WT9055 digital sound level meter, covering its features, operation, technical parameters, and considerations. Includes setup, usage, and maintenance information.
Preview Wintact WT530 Manuale Utente Termometro a Infrarossi
Guida completa per l'utilizzo del termometro a infrarossi Wintact WT530, che copre le specifiche tecniche, le istruzioni operative e le precauzioni di sicurezza per misurazioni accurate.
Preview Wintact WT85/WT85B Sound Level Meter Instruction Manual
Instruction manual for the Wintact WT85 and WT85B Sound Level Meters, detailing features, operation, calibration, technical parameters, and the dB-Tester App for the Bluetooth version.