1. Introduction
This manual provides detailed instructions for the installation, operation, and maintenance of your JIKONG JK-4.3LCD-TTL-P 4.3-inch screen display. This display is designed to work seamlessly with JIKONG V19 series Battery Management Systems (BMS), including models PB1A16S10P, PB1A16S15P, PB2A16S15P, PB2A16S20P, and PB2A16S30P. It offers real-time monitoring of battery parameters, protocol selection, and multilingual support for an enhanced user experience.
2. Safety Information
Please read and understand all safety instructions before installing or operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure all power sources are disconnected before making any connections to the BMS or display.
- Only use the provided wiring harness and connectors.
- Do not expose the device to moisture, extreme temperatures, or direct sunlight.
- Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
- Keep out of reach of children.
3. Package Contents
Verify that all items are present in your package:
- 1 x JIKONG JK-4.3LCD-TTL-P 4.3 Inch Screen Display
- 1 x Wiring Harness (approx. 500mm total length)

4. Product Overview
4.1. Features
- Display Size: 4.3-inch LCD screen.
- Compatibility: Designed for JIKONG V19 series BMS models (PB1A16S10P, PB1A16S15P, PB2A16S15P, PB2A16S20P, PB2A16S30P).
- Real-time Monitoring: Displays battery voltage (Vtg), current (Cur), battery capacity (Bat-Capacity Ah), remaining capacity (Rem-Capacity Ah), maximum and minimum cell voltages (Max.Cell, Min.Cell), temperature (Temp), power (Pwr kW), and alarm status (CHG/DCH).
- Multilingual Support: Supports Chinese, English, Thai, and Vietnamese languages.
- Wide Power Supply: Operates within a 9-36V power supply range.
- Communication: TTL level supported with a default baud rate of 115200bps.
- Protocol Selection: Allows selection of RS485 and CAN communication protocols.
- Parallel Mode: Capable of displaying data for up to 16 parallel battery packs, including individual pack capacity, status, and cell voltages.
- Customization: Supports display interface customization, including language and logo.
4.2. Components and Interfaces

- User Interface: Used for power supply and serial port signal connection. It features a HY2.0mm-6P vertical stick socket.
- Key Extension Interface: Used to control BMS startup and shutdown. It features an A1254WF-6A vertical sticker socket.
5. Setup Instructions
Follow these steps to connect and set up your JIKONG 4.3 Inch Screen Display:
- Power Off: Ensure your BMS and any connected battery systems are completely powered off before making any connections.
- Connect Wiring Harness: Connect one end of the provided wiring harness to the User Interface socket on the back of the 4.3-inch display.
- Connect to BMS: Connect the other end of the wiring harness to the corresponding communication port on your JIKONG V19 series BMS. Ensure the connection is secure and correctly oriented.
- Mount Display: Install the display in your desired location. The display dimensions are 136.5mm (width) x 95.4mm (height). The PCB area on the back is 96.5mm (width) x 55.4mm (height).
- Connect Key Extension (Optional): If you wish to control BMS startup/shutdown via an external key, connect it to the Key Extension Interface.
- Power On: Once all connections are secure, power on your BMS system. The display should power on automatically and show the main monitoring screen.



6. Operating Instructions
The display features a user-friendly interface with three main navigation buttons: GROUP, PACKS, and SETTING.
6.1. Main Display Screen
Upon powering on, the display will show the main monitoring screen, providing an overview of your battery system's status. This includes:
- Total Voltage (Vtg)
- Current (Cur)
- State of Charge (percentage)
- Battery Capacity (Bat-Capacity Ah)
- Remaining Capacity (Rem-Capacity Ah)
- Maximum Cell Voltage (Max.Cell)
- Minimum Cell Voltage (Min.Cell)
- Temperature (Temp)
- Power (Pwr kW)
- Alarm Status (CHG: ON/OFF, DCH: ON/OFF)
- Number of Packs (Packs)

6.2. Language Selection
To change the display language:
- Tap the SETTING button.
- Navigate to the 'Language' option.
- Select your preferred language from the available options: Chinese, English, Thai, or Vietnamese.
6.3. Protocol Selection
The display supports both RS485 and CAN communication protocols. To select the appropriate protocol:
- Tap the SETTING button.
- Navigate to the 'RS485 Protocol No.' or 'CAN Protocol No.' option.
- Select the protocol corresponding to your BMS setup. For example, for RS485, options include