1. Introduction
This manual provides comprehensive instructions for the safe and efficient operation, installation, and maintenance of your Dobtian 2.2KW Air Cooling Spindle Motor. Please read this manual thoroughly before use to ensure optimal performance and longevity of the product.
2. Package Contents
Please verify that all components are present and undamaged upon unboxing. The contents vary based on the option purchased:
- ONLY Motor Box 110V/220V:
1 x 110V/220V 2.2KW Square Air Cooling Spindle Motor with Flange in Junction Box - ONLY Motor Plug 110V/220V:
1 x 110V/220V 2.2KW Square Air Cooling Spindle Motor with Flange in Aviation Plug - Full Kit Box 110V/220V:
1 x 110V/220V 2.2KW Square Air Cooling Spindle Motor with Flange in Junction Box
1 x 110V/220V 2.2KW Inverter (YL VFD)
13 x ER20 Spring Collets (1mm / 2mm / 3mm / 4mm / 5mm / 6mm / 7mm / 8mm / 9mm / 10mm / 11mm / 12mm / 13mm) - Full Kit Plug 110V/220V:
1 x 110V/220V 2.2KW Square Air Cooling Spindle Motor with Flange in Aviation Plug
1 x 110V/220V 2.2KW Inverter (YL VFD)
13 x ER20 Spring Collets (1mm / 2mm / 3mm / 4mm / 5mm / 6mm / 7mm / 8mm / 9mm / 10mm / 11mm / 12mm / 13mm)
3. Specifications
3.1 Spindle Motor Specifications
| Attribute | Value |
|---|---|
| Brand Name | Dobtian |
| Model Number | 2.2KW Spindle (GDZ80X73-2.2) |
| Product Type | Air Cooling Spindle |
| Material | Stainless Steel |
| Power | 2.2KW |
| Voltage | 110V/220V AC |
| Current | 8A |
| Frequency | 0-400Hz |
| Operating Speed | 0-24000rpm |
| Cooling Type | Air-cooled (with fans) |
| Runout off | Less than 0.01mm |
| Collet | ER20 |
| Bearings | 4pcs bearing |
| With Flange? | Yes |
| Type 1 (Connection) | Junction Box |
| Type 2 (Connection) | Aviation Plug |
| Application | Milling, Wood/ PVC/PCB/PMMA/Plastic/Aluminum carving/engraving machine, advertisement engraving machine, CNC router machine, small sized processing center, high speed centrifuge etc. |
| Certification | CE |
| Origin | Mainland China |
3.2 Inverter (YL VFD) Specifications
| Attribute | Value |
|---|---|
| Input Voltage | AC 220V |
| Output Voltage | AC 220V/110V |
| Input Phase | 1 or 3 phase |
| Output Phase | 3 phase |
3.3 Collet Specifications (ER20 Spring Collets)
Sizes included: 1mm, 2mm, 3mm, 4mm, 5mm, 6mm, 7mm, 8mm, 9mm, 10mm, 11mm, 12mm, 13mm
3.4 Spindle Dimensions

3.5 Inverter Dimensions

4. Setup and Installation
4.1 General Precautions
This machine is strictly packaged before leaving the factory. However, due to various transportation factors, please pay special attention to the following before assembling. If any abnormality is found, notify the distributor or related personnel.
- Check for damage or deformation during transportation.
- Confirm that a YL series inverter and a manual are included when unpacking.
- Verify that the ordered specifications match the nameplate (Working voltage and KVA number).
- Ensure internal assembly parts, wiring, and circuit board are normal.
- Confirm all terminals are locked tightly, and there is no foreign matter in the machine.
- Check that the buttons of the operator are normal.
- Verify the presence of additional accessories.
4.2 Installation Location and Environment
Ensure the installation environment meets the following conditions:
- Ambient temperature: -5°C to 40°C with good ventilation.
- No dripping water and low humidity.
- No direct sunlight, high temperature, or severe dust.
- No corrosive gas or liquid.
- Minimal dust, oil, or metal particles.
- No vibration, allowing for easy maintenance and inspection.
- No electromagnetic noise interference.
Important:
- Sufficient space must be left around the inverter for cooling and maintenance.
- Install the inverter vertically for good cooling and smooth air circulation.
- If the installation surface is not secure, place a flat plate under the inverter base. A loose surface can cause stress and damage to main circuit parts.
- The installation wall should be made of non-combustible materials (e.g., iron plates).
- When installing multiple inverters in the same cabinet, ensure proper spacing (up and down) and add a baffle plate in the middle.
4.3 Wiring Diagrams and Terminal Descriptions
Ensure correct connection of the inverter main circuit and control signal wires. Incorrect power supply connection (e.g., connecting to U.V.W terminals instead of N/L) can damage the inverter. The environment of the installation site will affect the service life of the inverter.
4.3.1 Main Circuit Terminal Description
| Terminal Symbol | Description |
|---|---|
| N L | Power input terminal (220V inverter is single-phase 220V input, 110V inverter is single-phase 110V input) |
| U.V.W | Inverter output terminal (220V inverter is three-phase 220V output, 110V inverter is three-phase 110V output) |
| + DB - | Braking resistor connection end optional (see page 27 of the full PDF manual for details on braking resistor configuration) |
| FG | Frame Ground |
4.3.2 Control Terminal Description
| Terminal Symbol | Description |
|---|---|
| NC | NOTCONNECTED |
| MO | Triode output |
| FWD | Forward |
| REV | Reverse |
| X1, X2, X3, X4 | Multi-function input 1, 2, 3, 4 |
| XGND | Common terminal of digital control signal |
| XVCC | External input 15V |
| GND | Analog control signal common terminal |
| VI1 | Analog current frequency command |
| 10V | Power supply for speed setting |
| 13V | External power supply |
| AO | Analog output |
| NC1 | Relay normally closed contact |
| NO1 | Relay normally open contact |
| CM1 | Relay common terminal |
4.3.3 Schematic Diagram

4.3.4 Panel Control Wiring and Parameter Setting

4.3.5 Three-wire Control Wiring and Parameter Setting

4.3.6 Analog Quantity Control Wiring and Parameter Setting

4.3.7 External Potentiometer with Switch Control Wiring and Parameter Setting

4.4 Collet Installation

5. Operating Instructions
5.1 Digital Operator Panel Description

5.2 Operation Example: Parameter Upload/Download
Upload Inverter Host Parameters to Digital Operator:
- Press and hold the STOP button.
- While holding STOP, press the Up Arrow button. The digital operator will automatically read all parameters from the inverter host and save them, overwriting existing parameters in the operator.
- After uploading, press the PRGM key to exit. If an error occurs, its number will be displayed. Press PRGM again to clear the error and retry.
Download Parameters from Digital Operator to Inverter Host:
- Press and hold the STOP button.
- While holding STOP, press the Down Arrow button. The digital operator will automatically download all parameters to the inverter host, overwriting existing parameters.
- After downloading, the parameters of the digital operator remain unchanged.
5.3 Parameter Setting Method
- Press the PRGM key until the inverter displays "Pyy.xx" to enter parameter setting state (yy = group number, xx = parameter number).
- Use the Up/Down Arrow keys to select the desired parameter group and number.
- Press the SET key to enter the parameter value setting state. The display will show the current value (e.g., 60.0).
- Use the Up/Down Arrow keys to modify the parameter value.
- Press the SET key to save the modified parameter value. Alternatively, press PRGM to exit without saving changes.
Tip: Use the DISP key to quickly select parameter groups/numbers or digits for modification when flashing.
Note: If the parameter table is locked (P00.13=1), parameters can only be viewed, not modified. Parameters can only be saved when the inverter is stopped. While running, settings are effective but not saved until the inverter stops.
5.4 Trial Run Inspection
Before operation, perform the following checks:
- Wiring Check: Verify there are no wiring errors. Specifically, ensure the power supply is not incorrectly connected to the U.V.W motor terminals; power should be input from the N/L terminals.
- Debris Check: Ensure no metal chips or wires remain on the inverter substrate and wiring terminals that could cause short circuits.
- Secure Connections: Confirm all screws are tightly locked and connectors are not loose.
- Output Check: Verify that the output part has no short circuit or ground fault.
Inverter Cooling Fan Trial Run: Each time the STOP button is pressed, the cooling fan will run for approximately 30 seconds to allow the user to observe its working status.
5.5 Function Table (Excerpt)
For a complete list of parameters and their detailed descriptions, please refer to the full PDF manual, section 7.1 Function table (pages 14-25).
| Parameter No. | Name | Setting Range and Meaning | Factory Default |
|---|---|---|---|
| P00.00 | Main digital frequency | 0.0-600.0HZ | 400.0HZ |
| P00.01 | Start/stop command source | 0: Operate by panel 1: External terminal (STOP effective) 2: External terminal (STOP invalid) 3: Modbus Rs485 | 0 |
| P00.03 | Motor stop mode | 0: Decelerate to stop 1: Free stop 2: Immediate DC braking | 0 |
| P00.13 | Parameter recovery/locking/read and write | 0: Allow set 1: Forbid set (locked) 10: Restore factory settings | 0 |
| P03.09 | Panel potentiometer, upper limit of frequency setting | 0-120HZ(400HZ) | 400Hz |
| P12.19 | PWM frequency | 2.0-15.0KHZ | 8.0KHZ (220V) / 10.0KHz (110V) |
5.6 Multi-speed Command-Frequency Section
The inverter supports multi-speed control via external inputs. The following table shows the correspondence between input combinations and frequency sections:
| Multi-speed input X3 | Multi-speed input X2 | Multi-speed input X1 | Operating frequency section/corresponding parameters |
|---|---|---|---|
| open circuit | open circuit | open circuit | 1st section frequency/P07.00 |
| open circuit | open circuit | closure | 2nd section frequency/P07.01 (High) |
| open circuit | closure | open circuit | 3rd section frequency/P07.02 (Medium) |
| open circuit | closure | closure | 4th section frequency/P07.03 |
| closure | open circuit | open circuit | 5th section frequency/P07.04 (Low) |
| closure | open circuit | closure | 6th section frequency/P07.05 |
| closure | closure | open circuit | 7th section frequency/P07.06 |
| closure | closure | closure | 8th section frequency/P07.07 |
5.7 Toggle Switch Configuration
The toggle switches on the inverter can be configured as follows:
| Switch Position | Function |
|---|---|
| 1, 2 Push up | 1, 2, 3, 4 Push down to 5V |
| 3, 4 Push down to 10V |
6. Care and Maintenance
Proper care and maintenance are crucial for the longevity and performance of your spindle motor.
- Power Supply: Ensure the spindle frequency power supply is connected to the rated voltage and frequency consistent with the electro-spindle's technical parameters. Spindle speed can be adjusted by changing the frequency, with voltage proportional to the change.
- Storage: When the spindle is not in use, apply compressed air to blow out any static coolant from the pipes to prevent rust and clogging of water holes. The spindle's appearance should be oiled. Store it in a dry place with the shaft protection device in place.
- Bearing Replacement: Spindle bearings should only be replaced by professional and technical personnel using supporting special tools. Bearings should be replaced only after being fully cleaned, without removing the stator coils.
7. Troubleshooting
This section provides common fault information and methods for troubleshooting. For detailed parameter settings mentioned, refer to the full PDF manual.
| Error Code/Fault | Phenomenon | Analysis and Solutions |
|---|---|---|
| Er.00 | Power failure, power supply voltage is lower than 140VAC | 1. Check input power voltage (150-250V). Too high voltage damages inverter. 2. For large inertia loads, deceleration time setting (P01.02) may be too small. |
| Er.01 | Power supply voltage is higher than 290VAC, or internal bus voltage is too high | 1. Inaccurate detection of power supply voltage by inverter (requires maintenance). 2. For large inertia loads, consider installing an external braking resistor. |
| Er.02 | The current is too large | Check if motor is short-circuited, connections are correct, or mechanical load is too large. Otherwise, maintenance is required. |
| Er.03 | External PWM circuit error | Internal PWM circuit error. Turn off power for 1 minute, then retry. If persistent, maintenance is required. |
| Er.04 | IPM alarm (short circuit) | 1. Internal power unit module error. 2. Acceleration/deceleration time settings (P06.01-P06.18) are too short. 3. Inverter overcurrent/overheated, check motor/load. 4. Input voltage too high/low or fluctuates greatly. 5. Inverter and motor power mismatch, or star/delta wiring is wrong. 6. DC braking parameters (P01.09-P01.17) set improperly. 7. VF parameters (P00.04-P00.12) set improperly. 8. Cooling fan damaged/blocked, poor heat dissipation. 9. Gate drive voltage of power component too high/low. |
| Er.05 | External fault signal is input | Motor stops, displays code. Reset to clear. No maintenance required. |
| Er.06 | Internal data storage error | Error in internal data parameter storage. Turn off power for 1 minute, then test. |
| Er.07 | Over temperature | 1. Inverter internal temperature too high (>65°C). 2. Cooling fan not rotating (check P12.11 for fan operating mode). 3. Motor short-circuited or load too large. 4. Poor heat conduction between internal module and heat sink. |
| Er.08 | NTC temperature measurement error | Internal temperature detection circuit or sensor faulty. Requires repair. |
| Er.10 | Power down prompt | Check input power voltage is within range. |
| Er.11 | RS485 communication is disconnected and error occurs | Related to parameters P03.03, P03.04. |
| Er.12 | Parameter error | Check parameter settings. |
| Er.15 | Motor overheated | Reduce load or check cooling. |
8. User Tips
- Grounding: Always ensure proper grounding of both the spindle motor and the inverter to prevent electrical hazards and ensure stable operation.
- Voltage Verification: Double-check the voltage settings on the inverter (P00.00, P00.04, P00.05, P00.07, P00.08, P00.09, P00.10) match your power supply and spindle requirements before powering on.
- Debris Management: Regularly inspect and clean the spindle and work area to prevent accumulation of dust and chips, which can affect performance and cooling.
- Parameter Backup: After configuring your desired parameters, consider using the parameter upload function (Section 5.2) to save your settings.
- Braking Resistor: For applications with large inertia or requiring rapid braking, consider installing a braking resistor. Refer to the full PDF manual for configuration details (page 33, section 13.1).
9. Warranty and Support
We provide a 1-year warranty for this product and are committed to resolving any after-sales issues. All goods are checked before dispatch to ensure high quality. If you have any questions or require assistance, please feel free to contact us.