1. Introduction
Thank you for choosing the Earnmee Adjustable DC Laboratory Bench Power Supply. This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your device. Please read this manual thoroughly before use and keep it for future reference.
2. Safety Instructions
- Always connect the power supply to a grounded outlet.
- Ensure the input voltage matches the specified AC 220V±10%, 50/60Hz.
- Do not operate the device in wet or damp conditions.
- Do not open the casing; there are no user-serviceable parts inside. Refer servicing to qualified personnel.
- Ensure adequate ventilation around the unit to prevent overheating.
- Avoid short-circuiting the output terminals. The unit has short-circuit protection, but prolonged short circuits can cause damage.
- Disconnect power before making any connections or disconnections.
3. Package Contents
Upon unpacking, please verify that all items are present and in good condition:
- Earnmee Adjustable DC Laboratory Bench Power Supply Unit
- Power Cord
- Output Test Leads (may vary by model)
- User Manual (this document)

4. Product Overview
4.1 Front Panel

- Digital Display: Shows Voltage (V), Current (A), Power (W), and Load Equivalent Resistance (R).
- Voltage Adjustment Knobs (C.V.): Fine and coarse adjustment for output voltage.
- Current Adjustment Knobs (C.C.): Fine and coarse adjustment for output current limit.
- Power Button: Turns the unit on/off.
- Output Terminals (Front): GND (Ground), + (Positive), - (Negative) for connecting loads. Maximum 10A output on front terminals.
4.2 Rear Panel

- Cooling Fan: Automatically regulates temperature. Ensure it is not obstructed.
- AC Power Input: For connecting the main power cord.
- Output Terminals (Rear): Main OUTPUT + (Positive) and - (Negative) terminals for higher current applications.
5. Setup Instructions
5.1 Unpacking and Placement
- Carefully remove the power supply from its packaging.
- Place the unit on a stable, level surface.
- Ensure there is sufficient space (at least 10 cm) around the unit for proper ventilation, especially around the cooling fan on the rear panel.
- Keep the unit away from direct sunlight, heat sources, and excessive dust or moisture.
5.2 Power Connection
- Ensure the power switch on the front panel is in the OFF position.
- Connect the provided power cord to the AC power input socket on the rear panel of the power supply.
- Plug the other end of the power cord into a grounded AC 220V±10%, 50/60Hz power outlet.
5.3 Output Connection
Use appropriate test leads for your application. For currents up to 10A, the front terminals can be used. For higher currents, use the rear output terminals.
- Connect the positive (+) terminal of your load to the positive (+) output terminal of the power supply.
- Connect the negative (-) terminal of your load to the negative (-) output terminal of the power supply.
- If grounding is required for your application, connect the GND terminal to the appropriate point in your circuit.
6. Operating Instructions
6.1 Power On/Off
- Press the red power button on the front panel to turn the unit ON. The display will illuminate.
- To turn OFF, press the power button again.
6.2 Voltage and Current Adjustment
- Voltage Adjustment: Use the C.V. (Constant Voltage) knobs to set the desired output voltage. The coarse knob makes large adjustments, while the fine knob allows for precise tuning.
- Current Limit Adjustment: Use the C.C. (Constant Current) knobs to set the maximum output current. This acts as a current limit to protect your load. When the load current reaches this preset limit, the power supply will switch to constant current mode.
6.3 Display Readings
The 4-bit digital display provides real-time readings of:
- Output Voltage (V)
- Output Current (A)
- Output Power (W)
- Load Equivalent Resistance (R)
6.4 Protection Features
The power supply is equipped with five powerful protection mechanisms:
- Overload Protection for Voltage
- Overload Protection for Current
- Overload Protection for Power
- Overload Protection for Temperature
- Short Circuit Protection
These features help prevent damage to both the power supply and the connected load in case of abnormal operating conditions.
7. Maintenance
7.1 Cleaning
To maintain optimal performance and longevity, keep the unit clean:
- Disconnect the power supply from the main power outlet before cleaning.
- Use a soft, dry cloth to wipe the exterior of the unit.
- Do not use abrasive cleaners, solvents, or harsh chemicals.
- Periodically check and clean the cooling fan vents to ensure unobstructed airflow.
7.2 Storage
If storing the unit for an extended period, ensure it is kept in a suitable environment:
- Ambient temperature: -20℃ to 80℃
- Relative Humidity: ≤80%
- Store in a dry, dust-free location.
8. Troubleshooting
- No Power: Check the power cord connection to both the unit and the wall outlet. Ensure the power outlet is functional.
- No Output Voltage/Current: Ensure the power supply is turned on. Check all output connections to the load. Verify that the voltage and current limit settings are appropriate for your application.
- Unit Overheating: Ensure the cooling fan vents are clear and unobstructed. Operate the unit within its specified environmental conditions.
- Unexpected Shutdown: This may indicate activation of one of the built-in protection features (overload, over-temperature, short circuit). Disconnect the load, check for faults, and restart the unit.
If problems persist, contact customer support for assistance.
9. Specifications
10. Warranty and Support
This Earnmee power supply comes with a 1-Year Warranty from the date of purchase, covering manufacturing defects. Please retain your proof of purchase for warranty claims.
For technical support, warranty inquiries, or service, please contact your vendor or the manufacturer directly. Provide your product model and a detailed description of the issue for faster assistance.
11. User Tips
- Proper Ventilation: To ensure the longevity and stable operation of your power supply, always ensure that the cooling fan and vents are clear of obstructions. Good airflow is crucial, especially during high-power operation.
- Start with Low Settings: When connecting a new circuit or load, it's good practice to start with the voltage and current limits set to their lowest values and gradually increase them to the desired levels. This helps prevent accidental damage to your circuit.
- Check Connections: Before powering on, always double-check all output connections to ensure they are secure and correctly polarized. Loose connections can lead to unstable operation or damage.