1. Introduction
The Mestek CM87Pro is a professional-grade digital clamp meter designed for accurate and reliable electrical measurements. It features True RMS technology, automatic range selection, and a wide array of functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, and temperature measurement. This manual provides essential information for the safe and effective use of your CM87Pro clamp meter.

Image: Mestek CM87Pro Digital Clamp Meter, highlighting its capabilities for measuring current, voltage, resistance, capacitance, and frequency.
2. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition. If any items are missing or damaged, please contact your vendor.
Video: Unboxing the Mestek CM87Pro Digital Clamp Meter, showing the contents of the package.

Image: Detailed parts list included with the CM87Pro.
- Mestek CM87Pro Digital Clamp Meter
- K-type Thermocouple
- Test Probes (Red and Black)
- Instrument Storage Bag
- User Manual
- Packaging Box
3. Safety Information
Please read all safety warnings and operating instructions before using this instrument. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always ensure the meter is in the correct function and range before making measurements.
- Do not apply more than the rated voltage, as marked on the meter, between terminals or between any terminal and ground.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. These voltages pose a shock hazard.
- Keep your fingers behind the probe barriers during measurement.
- Replace the battery immediately when the low battery indicator appears to ensure accurate readings.
- Do not use the meter if it appears damaged or if the case is open.
- Always disconnect the test leads from the circuit before changing functions.
4. Product Overview
Familiarize yourself with the components and controls of your Mestek CM87Pro clamp meter.

Image: Front and side view of the CM87Pro with labeled components.
- NCV Sensing Area: Used for non-contact voltage detection.
- Current Sensing Zone (Clamp Jaw): For non-contact AC/DC current measurement. Jaw opening: 42mm.
- LED Lamp: Provides illumination for dark work areas.
- Flashlight/Data Hold Key: Activates the flashlight and holds the current display reading.
- Trigger: Opens and closes the clamp jaw.
- Function Knob: Selects the desired measurement function.
- Function Switch Key (SEL): Toggles between different measurement modes within a function (e.g., AC/DC, °C/°F).
- VFD/INRUSH Button: Activates Variable Frequency Drive measurement or Inrush current measurement.
- ZERO Button: Used to zero the DC current reading to eliminate magnetic field interference.
- MAX/MIN Button: Records maximum and minimum values during measurement.
- Display: VA color screen showing measurement readings and indicators.
- Input Terminals (COM, INPUT): For connecting test probes.
5. Setup
5.1 Battery Installation
The Mestek CM87Pro requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:
- Ensure the meter is turned off and disconnect all test leads.
- Locate the battery compartment cover on the back of the meter.
- Use a screwdriver to open the battery compartment.
- Insert two AAA batteries, observing the correct polarity (+ and -).
- Replace the battery compartment cover and secure it with the screw.
The meter features a low battery indication, which will appear when the battery voltage drops below 2.4V.
6. Operating Modes
Turn the function knob to select the desired measurement mode. Use the 'SEL' button to switch between AC/DC or other sub-functions where applicable.
6.1 Current Measurement (AC/DC)
To measure current, use the clamp jaw. Place a single wire of the tested circuit at the center of the clamp head. Ensure the clamp is fully closed. The instrument screen will display the current value.

Image: Demonstrating AC and DC current measurement using the clamp function.
6.2 Voltage Measurement (AC/DC)
Connect the test probes to the COM and INPUT terminals. Select the voltage function using the knob. The meter supports automatic recognition of AC/DC voltage (AUTO-VLOZ) and VFD measurement for high-frequency signals.

Image: Measuring AC and DC voltage with test probes.

Image: Automatic recognition of AC/DC voltage (AUTO-VLOZ).
6.3 Resistance, Capacitance, Diode, and Continuity Test
Connect the test probes to the COM and INPUT terminals. Select the appropriate function using the knob and 'SEL' button to cycle through modes.

Image: Demonstrating Capacitance, Resistance, Diode, and Continuity (On Off Test) measurements.
6.4 Frequency Measurement
To measure frequency, select the Hz function. The screen will display the frequency value of the tested signal source and its percentage.

Image: Frequency measurement in progress.
6.5 Temperature Measurement
Connect the K-type thermocouple to the meter's input terminals. Select the temperature function. Place the thermocouple probe in contact with the object or liquid being measured. Briefly press the 'SEL' key to convert between °C and °F.

Image: Contact temperature measurement using the K-type thermocouple.
6.6 Non-Contact Voltage (NCV) Detection
Bring the NCV sensing area of the instrument close to the circuit. Different alarm prompts (audible and visual) will be sounded according to the voltage intensity, and the screen may display 'L' for low voltage or 'H' for high voltage.

Image: Non-contact AC voltage detection indicating low and high voltage.
6.7 LIVE Wire Recognition
Use a test probe to touch the tested conductor. If it's a live wire, the red backlight will illuminate, and the buzzer will sound an alarm.

Image: Live wire recognition in action.
6.8 Inrush Current Measurement
In AC current mode, press and hold the 'INRUSH' button to measure the peak current when a machine is started. Ensure the load power supply is disconnected before measuring.

Image: Surge current measurement for motor startup.
6.9 Data Hold
Short press the 'HOLD' key to lock the current reading on the display. The meter will sound a warning every 2 seconds to indicate that data is held.

Image: Data Hold function locking the displayed reading.
6.10 MAX/MIN Measurement
In AC/DC voltage or AC/DC current mode, use the 'MAX/MIN' button to record the maximum and minimum values measured. This is useful for monitoring fluctuations.

Image: MAX/MIN measurement for capturing peak and trough values.
6.11 DC Current Zeroing
In DC current mode, long press the 'ZERO' key to eliminate any base number caused by magnetic field interference in the environment. This ensures more accurate measurement results.

Image: DC current zeroing process for improved accuracy.
7. Maintenance
7.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Keep the clamp jaw free of dust and debris.
7.2 Storage
When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its protective bag in a cool, dry place, away from direct sunlight and extreme temperatures.
8. Troubleshooting
- Meter does not turn on: Check battery installation and ensure batteries are not depleted. Replace if necessary.
- Inaccurate readings: Ensure correct function selection, proper probe connection, and that the clamp jaw is fully closed for current measurements. Zero the DC current if interference is suspected.
- 'OL' or '-OL' displayed: This indicates an over-range condition. The measured value exceeds the meter's maximum range for the selected function. Switch to a higher range if available, or verify the circuit.
- No continuity sound: Ensure the continuity function is selected. If the buzzer is still silent, check for an open circuit or a faulty test lead.
9. Specifications
The following table outlines the technical parameters of the Mestek CM87Pro Digital Clamp Meter:

Image: Detailed technical specifications for the CM87Pro model.
| Parameter | Value |
|---|---|
| Model Number | CM87 Pro |
| Display Type | Digital Only (5999 counts) |
| DC Current Range | 0-1000A |
| AC Current Range | 0-1000A |
| DC Voltage Range | 0-1000V |
| AC Voltage Range | 0-750V |
| Capacitance Range | 0-60mF |
| Resistance Range | 0-60MΩ |
| Frequency Measure | 0-10MHZ |
| Operating Temperature | 0-50 ℃ |
| Storage Temperature | -10℃ ~ 60℃ |
| Power Supply | 2*1.5V AAA batteries |
| Jaw Opening | 42mm |
| Weight | ~240g (excluding battery) |
| Dimensions | 218 x 75 x 39mm |
| Certifications | CE, FCC, RoHS |
| True-RMS | Yes |
| NCV (Non-Contact Voltage) | Yes |
| LIVE wire recognition | Yes |
| Inrush Current | 0-1000A support |
| VFD (Variable Frequency Drive) | Yes |
| Overload Protection | Yes |
| Continuity Buzzer | Yes |
| Data Hold | Yes |
| Backlight | Yes |
| Auto Power Off | About 15 minutes |
| Low Battery Indication | When less than 2.4V |
10. User Tips
- The continuity mode on the CM87Pro does indeed emit an audible sound, making it easy to identify continuous circuits without needing to look at the display.
- For precise DC current measurements, always remember to use the 'ZERO' function to calibrate the meter and eliminate any residual magnetic interference before taking a reading.
- The large jaw design (42mm) is particularly useful for measuring current on thicker cables, offering versatility in various electrical applications.
11. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your original point of purchase or the manufacturer's official website. Keep your purchase receipt as proof of purchase for warranty claims.