1. Introduction
The Mestek CM87C is a professional-grade digital clamp meter designed for electricians and DIY enthusiasts. It offers a wide range of measurement functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, temperature, diode, and continuity. Featuring True-RMS for accurate readings, Non-Contact Voltage (NCV) detection, Live wire recognition, and Inrush Current measurement, this tool is versatile for various electrical testing needs.
This manual provides essential information for the safe and effective use of your Mestek CM87C Digital Clamp Meter. Please read it thoroughly before operation and keep it for future reference. A detailed user manual is also available in PDF format for download.
2. Package Contents
Carefully unpack your new clamp meter and check for the following items:
- 1 x Mestek CM87C Digital Clamp Meter
- 1 x K-type Thermocouple (Temperature Probe)
- 1 x Pair of Test Probes (Red and Black)
- 1 x Instrument Storage Bag
- 1 x User Manual (Printed)
- 1 x Packaging Box

Figure 2.1: Included accessories and main unit.
Video 2.1: Unboxing the Mestek Digital Clamp Meter and its accessories.
3. Product Features and Overview
The CM87C model is equipped with advanced features for comprehensive electrical diagnostics:
- Measurement Range: 0-600A AC/DC Current, 0-600V AC/DC Voltage.
- Display: 5999 Counts, Auto Range.
- True-RMS: Provides accurate readings for non-sinusoidal waveforms.
- Inrush Current: Measures peak current during motor startup.
- NCV (Non-Contact Voltage) Detection: Safely detects AC voltage without direct contact.
- LIVE Wire Recognition: Identifies live wires for enhanced safety.
- Temperature Measurement: Supports K-type thermocouple for contact temperature readings.
- Other Functions: Resistance, Capacitance, Frequency, Diode Test, Continuity Buzzer, Data Hold, Backlight, Flashlight, Auto Power Off, Low Battery Indication.
- Jaw Opening: 30mm, suitable for various cable diameters.

Figure 3.1: Front view of the CM87C with labeled components: NCV sensing area, Current sensing zone, LED lamp, Flashlight/Data Hold Key, Trigger, Function knob, Function switch key, VFD/INRUSH, Backlight/ZERO, Max/Min switching, Display, Black probe input, Red probe input.
4. Setup
4.1 Battery Installation
The Mestek CM87C requires two 1.5V AAA batteries (not included). To install:
- Locate the battery compartment cover on the back of the device.
- Use a screwdriver to open the battery compartment.
- Insert two AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
- Replace the cover and secure it with the screw.
4.2 Connecting Test Probes
For voltage, resistance, capacitance, frequency, diode, and continuity measurements:
- Insert the red test lead into the 'INPUT' jack.
- Insert the black test lead into the 'COM' jack.
4.3 Connecting K-type Thermocouple
For temperature measurements:
- Insert the K-type thermocouple plug into the 'INPUT' and 'COM' jacks, ensuring correct polarity (usually red to INPUT, black to COM, or as marked on the probe).
5. Operating Instructions
Always ensure the meter is set to the correct function before making any measurements. Observe all safety precautions.
5.1 Power On/Off
Rotate the function knob from 'OFF' to any desired measurement function to power on the device. Rotate it back to 'OFF' to power off. The device also features an automatic shutdown after approximately 15 minutes of inactivity.
5.2 AC/DC Current Measurement
To measure current, ensure the circuit is de-energized if possible, or take appropriate safety measures.
- Rotate the function knob to the '600A' position (AC or DC current symbol).
- Open the clamp jaw by pressing the trigger.
- Place a single conductor (not a bundled cable) of the circuit to be measured within the center of the clamp jaw.
- Ensure the jaw is fully closed. The current value will be displayed on the screen.

Figure 5.1: Measuring AC current in a breaker panel and DC current in a car battery circuit.
5.3 AC/DC Voltage Measurement
Use the test probes for voltage measurements.
- Rotate the function knob to the 'V~' (AC Voltage) or 'V-' (DC Voltage) position. The meter may automatically recognize AC/DC voltage (AUTO-VLOZ).
- Connect the test probes in parallel to the circuit or component you wish to measure.
- The voltage value will be displayed on the screen.

Figure 5.2: Measuring AC voltage in a breaker panel and DC voltage across a car battery.
5.4 Resistance Measurement
- Rotate the function knob to the 'Ω' position.
- Connect the test probes across the component to be measured (ensure the component is de-energized).
- The resistance value will be displayed.
5.5 Capacitance Measurement
- Rotate the function knob to the '╂' (Capacitance) position.
- Connect the test probes across the capacitor (ensure the capacitor is discharged before testing).
- The capacitance value will be displayed.
5.6 Frequency Measurement
- Rotate the function knob to the 'Hz%' position.
- Connect the test probes to the signal source.
- The frequency (Hz) and duty cycle (%) will be displayed.
5.7 Temperature Measurement
- Rotate the function knob to the '℃/℉' position.
- Connect the K-type thermocouple.
- Place the thermocouple probe in contact with the object or liquid to be measured.
- Press the 'SEL' key briefly to switch between Celsius (°C) and Fahrenheit (°F).

Figure 5.3: Measuring contact temperature using the K-type thermocouple.
5.8 NCV (Non-Contact Voltage) Detection
- Rotate the function knob to the 'NCV' position.
- Bring the NCV sensing area (top of the clamp jaw) close to the conductor or outlet.
- The meter will sound an alarm and the screen will display red, with different prompts ('-L' for low voltage, '-H' for high voltage) indicating the voltage intensity.

Figure 5.4: Non-contact AC voltage detection showing low and high voltage indications.
5.9 LIVE Wire Recognition
- Rotate the function knob to the 'LIVE' position.
- Use the red test probe to touch the tested conductor.
- If it's a live wire, the red backlight will illuminate, and the buzzer will sound an alarm. The screen will display 'LiVE'.

Figure 5.5: Identifying a live wire using the red test probe.
5.10 Inrush Current Measurement
This function measures the peak current when a machine or motor starts up.
- Rotate the function knob to the 'INRUSH' position (usually combined with VFD).
- Before measuring, disconnect the load power supply.
- Place the clamp around the single conductor of the motor/machine.
- Start the machine. The meter will capture and display the inrush current.
5.11 DC Current Reset to Zero
In DC current mode, long press the 'ZERO' key to eliminate any base number caused by magnetic field interference in the usage environment, ensuring more accurate measurement results.

Figure 5.6: Resetting DC current to zero for accurate readings.
5.12 Data Hold (HOLD)
Short press the 'HOLD' key to lock the current displayed data. The buzzer will sound a warning every 2 seconds to remind you that you are in a locked state. Press 'HOLD' again to release.
5.13 MAX/MIN Measurement
In AC/DC voltage/current mode, press the 'MAX/MIN' button to record the maximum and minimum values measured. Press again to cycle through MAX, MIN, and current readings.
6. Maintenance
6.1 Cleaning
Wipe the meter with a dry, soft cloth. Do not use abrasives or solvents. Keep the display clean for clear readings.
6.2 Battery Replacement
When the low battery indicator appears on the display, replace the batteries promptly to ensure accurate measurements. Refer to section 4.1 for battery installation instructions.
6.3 Storage
If the meter is not used for a long period, remove the batteries to prevent leakage and damage. Store the meter in its protective storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not power on | Dead or incorrectly installed batteries | Check battery polarity, replace batteries |
| No reading or 'OL' displayed | Overload, open circuit, or incorrect range | Check connections, select appropriate range, ensure circuit is complete |
| Inaccurate readings | Low battery, external interference, or incorrect function selected | Replace batteries, move away from strong electromagnetic fields, select correct function |
| Buzzer not working | Not in continuity mode, or fault | Ensure function knob is set to continuity, check for damage |
8. Specifications
| Parameter | CM87A | CM87B | CM87C |
|---|---|---|---|
| DC Current | ✗ | ✗ | 0-600A |
| AC Current | 0-600A | 0-600A | 0-600A |
| K type temperature probe | ✗ | ✓ | ✓ |
| DC Voltage | 0-600V | 0-600V | 0-600V |
| AC Voltage | 0-600V | 0-600V | 0-600V |
| Capacitance | 0-4mF | 0-60mF | 0-60mF |
| Resistance | 0-40MΩ | 0-60MΩ | 0-60MΩ |
| Inrush current | ✗ | ✗ | 0-600A |
| Display counts | 3999 | 5999 | 5999 |
| Operation range | Auto range | Auto range | Auto range |
| Frequency measure | ✓ | ✓ | ✓, 0-10MHZ |
| Overload protection | ✓ | ✓ | ✓ |
| Continuity buzzer | ✓ | ✓ | ✓ |
| Jaw opening | 42mm | 42mm | 42mm |
| True-RMS | ✓ | ✓ | ✓ |
| Data hold | ✓ | ✓ | ✓ |
| Backlight | ✓ | ✓ | ✓ |
| Auto power off | ✓ | ✓ | ✓ |
| NCV | ✓ | ✓ | ✓ |
| LIVE wire recognition | ✓ | ✓ | ✓ |
| Diode | ✓ | ✓ | ✓ |
| Input impedance | 1MΩ | 1MΩ | 1MΩ |
| Low battery indication | < 2.4V | < 2.4V | < 2.4V |
| Battery | 2*1.5V AAA | 2*1.5V AAA | 2*1.5V AAA |
| Operating Temperature | 0°C ~ 50°C | ||
| Storage Temperature | -10°C ~ 60°C | ||
| Size | 218 x 75 x 39mm | ||
| Weight (excluding battery) | ~240g | ||
Note: Specifications are subject to change without notice.
9. User Tips
- DC Current Measurement: For models like CM87C that support DC current measurement, remember to use the 'ZERO' function before taking readings to eliminate any magnetic field interference and ensure accuracy.
- Safety First: Always double-check the function knob setting before connecting to any circuit. When measuring current, ensure only a single conductor is within the clamp jaw.
- Battery Life: Keep spare AAA batteries handy, especially for prolonged use, as low battery can affect measurement accuracy.
10. Warranty and Support
Your Mestek CM87C Digital Clamp Meter is designed for reliability and performance. For any technical assistance or warranty inquiries, please refer to the contact information provided by your original point of purchase. Keep your purchase receipt as proof of purchase.