1. Introduction

The Mestek Digital Clamp Meter Multimeter CM87C is a versatile and reliable tool designed for electricians and DIY enthusiasts. It offers a wide range of measurement functions including AC/DC current, AC/DC voltage, resistance, capacitance, frequency, temperature, and specialized features like Non-Contact Voltage (NCV) detection, Live Wire recognition, Inrush current measurement, and Variable Frequency Drive (VFD) measurement. This manual provides detailed instructions for safe and effective use of your clamp meter.

Mestek Digital Clamp Meter CM87C
Mestek Digital Clamp Meter CM87C

2. Safety Information

Always observe basic safety precautions when using this instrument to avoid electric shock, fire, or personal injury. Read all instructions carefully before use.

  • Do not exceed the maximum input values for any function.
  • Ensure the test leads are properly connected and the function switch is in the correct position before making measurements.
  • Do not use the meter if it appears damaged or if the insulation on the test leads is compromised.
  • Exercise extreme caution when working with voltages above 60V DC or 30V AC RMS, as these pose a shock hazard.
  • Always disconnect power to the circuit under test before measuring resistance, capacitance, or continuity.
  • Replace batteries when the low battery indicator appears to ensure accurate readings.

3. Package Contents

Verify that all items are present and undamaged upon opening the package:

  • Mestek Digital Clamp Meter (CM87C)
  • Test Probes (Red and Black)
  • K-type Thermocouple (for temperature measurement)
  • Instrument Storage Bag
  • User Manual
  • Packaging Box
Mestek Digital Clamp Meter CM87C Package Contents
Included items: Clamp meter, K-type thermocouple, User Manual, Test probes, Instrument storage bag, and packaging box.
Video: Unboxing the Mestek Digital Clamp Meter and its accessories.

4. Product Overview

Familiarize yourself with the components and controls of your clamp meter:

Mestek Digital Clamp Meter CM87C Labeled Diagram
Diagram of the CM87C Clamp Meter with labeled parts including NCV sensing area, current sensing zone, LED lamp, flashlight/data hold key, trigger, function knob, function switch key, VFD/INRUSH, backlight/ZERO, Max/Min switching, display, and probe inputs.

Key Features:

Mestek Digital Clamp Meter CM87C Featured Functions
Icons representing various functions: AC/DC current, AC/DC voltage, AUTO-V LoZ, Resistance, Capacitance, Diode, On/off buzzing (Continuity), Frequency, Temperature, NCV, Live, MIN/MAX, Zeroing function/data hold, VFD, Inrush, Backlight/Flashlight.

5. Setup

5.1. Battery Installation

The Mestek CM87C requires 2 x 1.5V AAA batteries (not included). To install or replace batteries:

  1. Ensure the meter is turned off.
  2. Locate the battery compartment on the back of the meter.
  3. Use a screwdriver to open the battery cover.
  4. Insert two 1.5V AAA batteries, observing the correct polarity (+/-).
  5. Securely close the battery cover.

The meter features a low battery indication when the voltage drops below 2.4V.

5.2. Initial Power On

Turn the function knob to any desired measurement mode to power on the device. The display will light up.

6. Operating Instructions

This section details how to use the various measurement functions of your Mestek CM87C clamp meter.

6.1. AC/DC Current Measurement

To measure current, use the clamp jaw. The large jaw design (42mm jaw opening) is suitable for measuring cables of various diameters.

  1. Turn the function knob to the AC/DC Current (600A) position.
  2. Press the 'SEL' button to switch between AC and DC current modes if necessary (CM87C supports both).
  3. Open the clamp jaw and place a single wire of the tested circuit at the center of the clamp.
  4. Ensure the clamp is fully closed. The instrument screen will display the current value.
AC and DC Current Measurement
Measuring AC current in a circuit breaker box and DC current in a car battery.

6.2. AC/DC Voltage Measurement

Use the test probes for voltage measurements.

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Turn the function knob to the AC/DC Voltage (600V) position. The meter features AUTO-VLOZ for automatic recognition of AC/DC voltage.
  3. Connect the test probes across the circuit or component to be measured.
  4. The screen will display the voltage value.
AC and DC Voltage Measurement
Measuring AC voltage in a panel and DC voltage in a car battery.

6.3. Resistance, Capacitance, Diode, and Continuity Test

These functions are typically grouped together on the function knob.

  1. Insert the red test lead into the 'INPUT' jack and the black test lead into the 'COM' jack.
  2. Turn the function knob to the Resistance/Capacitance/Diode/Continuity position.
  3. Use the 'SEL' button to cycle through the desired function.
  4. Resistance: Connect probes across the component.
  5. Capacitance: Connect probes across the capacitor.
  6. Diode: Connect probes across the diode.
  7. Continuity: Connect probes across the circuit. A buzzer will sound if continuity is detected.
Capacitance, Resistance, Diode, and Continuity Test
Illustrations for measuring capacitance, resistance, diode, and performing an on/off (continuity) test.

6.4. Non-Contact Voltage (NCV) Detection

The NCV function allows for safe detection of AC voltage without direct contact.

  1. Turn the function knob to the NCV position.
  2. Bring the NCV sensing area of the instrument close to the circuit or wire.
  3. Different alarm prompts (audible and visual) will be sounded according to the voltage intensity, and the screen will display red.
Non-Contact AC Voltage Detection
NCV detection showing low and high voltage indications with visual and audible alerts.

6.5. Live Wire Recognition

This feature helps identify live wires for safety.

  1. Insert the red test lead into the 'INPUT' jack.
  2. Turn the function knob to the LIVE position.
  3. Use the red probe to touch the tested conductor.
  4. If it's a live wire, the red backlight will illuminate, and the buzzer will sound an alarm.
Live Fire Line Recognition
Using the probe to detect a live wire, indicated by a red backlight and alarm.

6.6. Inrush Current Measurement

Measure the peak current when a machine is started.

  1. Turn the function knob to the AC Current mode.
  2. Press and hold the 'INRUSH' button.
  3. Before measuring, disconnect the load power supply.
  4. Place the clamp around the wire and activate the load. The meter will capture the inrush current.
Surge Current Measurement
Measuring surge current in an industrial setting.

6.7. VFD (Variable Frequency Drive) Measurement

Enabling VFD in AC voltage and current mode can effectively reduce interference of high-frequency signals on measurement results, providing more accurate readings for VFD circuits.

  1. Turn the function knob to AC Voltage or AC Current mode.
  2. Press the 'VFD' button to activate VFD mode.
  3. Proceed with your measurement as usual.

6.8. Temperature Measurement

The CM87C supports K-type temperature probes.

  1. Insert the K-type thermocouple into the 'INPUT' and 'COM' jacks, observing polarity.
  2. Turn the function knob to the Temperature position.
  3. Place the thermocouple probe in contact with the object or liquid being measured.
  4. Press the 'SEL' key briefly to convert between °C/°F.
Contact Temperature Measurement
Measuring temperature using the K-type thermocouple.

6.9. Data Hold (HOLD)

To freeze the current reading on the display:

  • During any measurement, short press the 'HOLD' button (often combined with Flashlight).
  • The reading will be held on the screen.
  • Short press 'HOLD' again to release.
  • In data lock state, the buzzer will sound a warning every 2 seconds.
HOLD Data Lock Function
The HOLD function freezes the current measurement on the display.

6.10. DC Current Reset to Zero

In DC current mode, long press the 'ZERO' key to eliminate the base number caused by magnetic field interference in the usage environment, thereby obtaining more accurate measurement results.

DC Current Zeroing Function
Comparison of DC current reading before and after resetting to zero.

6.11. MIN/MAX Measurement

This function allows you to record the minimum and maximum values during a measurement (available in AC/DC voltage and AC/DC current modes).

  1. Turn the function knob to the desired AC/DC Voltage or AC/DC Current mode.
  2. Press the 'MIN/MAX' button. The meter will start recording.
  3. Press 'MIN/MAX' again to cycle through MIN, MAX, and current readings.
  4. Long press 'MIN/MAX' to exit the mode.
MIN/MAX Measurement
Illustrates the MIN/MAX measurement function.

6.12. Frequency Measurement

The meter can display the frequency value of the tested signal source.

  1. Turn the function knob to the Frequency (Hz) position.
  2. Connect the test probes across the signal source.
  3. The screen will display the frequency value and synchronously display the percentage of the measured signal.
Frequency Measurement
Measuring frequency in an electrical panel.

6.13. Backlight and Flashlight

The meter is equipped with a backlight for the display and a flashlight for illuminating the work area.

  • Short press the backlight button (often combined with ZERO) to turn the display backlight on/off.
  • Short press the flashlight button (often combined with HOLD) to turn the flashlight on/off.

7. Specifications

Below are the general and technical specifications for the Mestek Digital Clamp Meter CM87C, along with a comparison to models CM87A and CM87B.

7.1. General Specifications

AttributeValue
Brand NameMESTEK
Display TypeDigital Only
DIY SuppliesElectrical
OriginMainland China
CertificationCE, FCC, RoHS
Operating Temperature0-50 ℃
Storage Temperature-10℃ ~ 60℃
Dimensions218 x 75 x 39 mm
Weight~240g (excluding battery)
Jaw Opening42mm
Power Supply2 x 1.5V AAA batteries
Low Battery IndicationWhen less than 2.4V
Automatic Shutdown TimeAbout 15 minutes
Backlight Automatic Off TimeAbout 3 minutes
Flashlight Automatic Shutdown TimeAbout 5 minutes
Maximum Input Voltage (COM to INPUT)AC/DC 600V
Full Range Overload Protection Voltage600V
Sample TimeAbout 3 times per second

7.2. Measurement Specifications (CM87C)

MeasurementRange (CM87C)
Display Counts5999
Operation RangeAuto range
DC Current0-600A
AC Current0-600A
Inrush Current0-600A
DC Voltage0-600V
AC Voltage0-600V
Resistance0-60MΩ
Capacitance0-60mF
Frequency Measure0-10MHZ
K type temperature probeSupport
True-RMSHave
Overload ProtectionSupport
Continuity BuzzerSupport
Data HoldHave
BacklightHave
Auto Power OffSupport
NCVSupport
LIVE Wire RecognitionSupport
DiodeHave
Input Impedance1MΩ

7.3. Model Comparison

Digital Clamp Meter Parameter Comparison
Comparison table for CM87A, CM87B, and CM87C models, highlighting differences in DC current, K-type probe support, inrush current, and display counts.

8. Maintenance

8.1. Cleaning

Wipe the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the display clean and dry.

8.2. Battery Replacement

When the low battery indicator appears on the display, replace the batteries as described in the 'Battery Installation' section (5.1). Always use 2 x 1.5V AAA batteries.

8.3. Storage

If the meter is not used for a long period, remove the batteries to prevent leakage and damage. Store the meter in its protective case in a cool, dry place, away from direct sunlight and extreme temperatures.

9. Troubleshooting

  • Meter does not power on: Check battery installation and ensure batteries are not depleted.
  • Inaccurate readings: Ensure the correct function is selected, test leads are properly connected, and the circuit is de-energized for resistance/capacitance. For DC current, use the zeroing function.
  • No NCV detection: Ensure the NCV sensor is close enough to the AC voltage source.
  • Display shows 'OL': The measurement exceeds the selected range. Select a higher range or ensure the value is within the meter's capabilities.

10. User Tips

  • For current measurements, always clamp around a single conductor, not a bundle of wires, to get an accurate reading.
  • Utilize the backlight in dimly lit environments for better visibility of the display.
  • The data hold function is useful for taking readings in hard-to-reach places where you can't see the display directly.
  • Remember to turn off the meter after use to conserve battery life, although it has an auto-power-off feature.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase.

© 2023 MESTEK. All rights reserved.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.