HYTAIS TS600

HYTAIS TS600 Infrared Non-Contact Thermometer User Manual

Model: TS600

Brand: HYTAIS

1. Introduction

The HYTAIS TS600 is a non-contact infrared thermometer designed for quick and accurate surface temperature measurements. It offers a wide temperature range, fast response time, and adjustable emissivity, making it suitable for various applications from home use to industrial inspections.

This device allows for safe temperature detection without direct contact, which is ideal for measuring high-temperature equipment, hazardous chemicals, or hard-to-reach objects.

Safety Information

  • Do not point the laser directly at eyes or indirectly off reflective surfaces.
  • Do not use the thermometer near explosive gases, steam, or dust.
  • Keep the device away from electromagnetic fields (e.g., arc welders, induction heaters).
  • Do not immerse the unit in water.
  • This product is suitable for temperature measurement on the surface of opaque objects.
  • When measuring, keep the distance from the target within 30cm for optimal accuracy.
  • Avoid strong reflection environments, glass, liquid, and other transparent materials, as these can affect measurement accuracy. For such materials, specialized temperature measurement equipment is recommended.

2. Key Features

HYTAIS TS600 Infrared Thermometer highlighting key features

Figure 2.1: HYTAIS TS600 with highlighted features

  • Non-Contact Measurement: Safely measures surface temperatures without direct contact.
  • Wide Temperature Range: Measures from -50℃ to 600℃ (-58℉ to 1112℉).
  • Fast Response: Provides readings in approximately 0.5 seconds.
  • Adjustable Emissivity: Emissivity adjustable from 0.1 to 1.0 to adapt to various surface types for improved accuracy.
  • Dual Temperature Units: Easily switch between Celsius (℃) and Fahrenheit (℉).
  • Laser Positioning: Equipped with an auxiliary laser point for accurate targeting of the measurement area.
  • HD Backlit Screen: Clear digital display with backlight for readability in various lighting conditions.
  • Automatic Shut-Off: Conserves battery life by automatically turning off after a period of inactivity.
  • Low Battery Indicator: Alerts the user when batteries need replacement.
  • High/Low Temperature Alarm: User-settable alarms for temperatures exceeding or falling below specified thresholds.
Additional functions of the thermometer including backlight, auto shut-off, C/F selection, and low battery indicator

Figure 2.2: Additional functions of the HYTAIS TS600

3. Product Components

Diagram showing the labeled parts of the HYTAIS TS600 thermometer: Laser, Thermometer probe, HD screen, MODE button, Laser aiming on/off button, °C/°F convert button, Power button, Battery holder.

Figure 3.1: Panel Introduction and Components

  1. Laser: Emits a laser dot for precise targeting of the measurement area.
  2. Thermometer Probe: The infrared sensor for temperature detection.
  3. HD Screen: Digital display for temperature readings and settings.
  4. MODE Button: Used to access and adjust settings like emissivity and alarm thresholds.
  5. Laser Aiming On/Off Button: Toggles the laser pointer.
  6. °C/°F Convert Button: Switches between Celsius and Fahrenheit temperature units.
  7. Power Button (Trigger): Activates the thermometer and initiates measurement.
  8. Battery Holder: Compartment for AAA batteries.

4. Setup

4.1 Battery Installation

The HYTAIS TS600 requires two (2) 1.5V AAA batteries (not included) for operation. Follow these steps to install the batteries:

  1. Locate the battery holder compartment at the bottom of the handle.
  2. Open the battery compartment cover.
  3. Insert two 1.5V AAA batteries, ensuring correct polarity (+ and -).
  4. Close the battery compartment cover securely.
Diagram showing easy battery replacement for the thermometer, indicating 2x1.5V AAA batteries are not included.

Figure 4.1: Battery Installation

5. Operation

5.1 Basic Temperature Measurement

  1. Point the thermometer at the target object.
  2. Pull and hold the Power Button (trigger) to activate the device and begin measurement. The temperature reading will appear on the HD screen.
  3. Release the trigger to hold the last measured temperature on the display.

5.2 Laser Aiming

The built-in laser helps to accurately target the measurement area.

  • To turn on/off the laser: Short press the "Laser Aiming On/Off" button (refer to Figure 3.1 for button location).
Image showing the thermometer with laser aiming at cupcakes in an oven, indicating wide range and fast reading.

Figure 5.1: Laser Aiming for precise measurement

5.3 Switching Temperature Units (℃/℉)

To switch between Celsius (℃) and Fahrenheit (℉):

  • Short press the "°C/°F Convert" button (refer to Figure 3.1 for button location). The display will change accordingly.
Image showing the thermometer display switching between Celsius and Fahrenheit.

Figure 5.2: Temperature Unit Switching

5.4 Emissivity Adjustment

Emissivity (ε) is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. Adjusting the emissivity setting on your thermometer ensures more accurate readings for various surfaces. The TS600 allows adjustment from 0.1 to 1.0.

  1. Long press the "MODE" button to enter the emissivity setting. The current emissivity value (e.g., "ε=0.95") will flash on the screen.
  2. Use the Up (▲) and Down (▼) buttons to adjust the emissivity value.
  3. Press the "MODE" button again to confirm the setting and exit.

Common Emissivity Values:

  • Cement: 0.96
  • Oil: 0.94
  • Wood: 0.94
  • Most organic materials, painted or oxidized surfaces: 0.95 (default)
Image showing adjustable emissivity for different materials like cement, oil, and wood.

Figure 5.3: Adjustable Emissivity for High Accuracy

5.5 High / Low Temperature Alarm Setting

The thermometer can be set to alert you if the measured temperature exceeds a high threshold or falls below a low threshold.

  1. Long press the "MODE" button until "Hi" appears on the screen. This is the High Temperature Alarm setting.
  2. Use the Up (▲) and Down (▼) buttons to set the desired high temperature threshold.
  3. Press the "MODE" button again to switch to the Low Temperature Alarm setting ("Low" will appear).
  4. Use the Up (▲) and Down (▼) buttons to set the desired low temperature threshold.
  5. Press the "MODE" button one more time to exit the alarm settings.

5.6 Distance to Spot Ratio (D:S)

The D:S ratio for the HYTAIS TS600 is 12:1. This means that for every 12 units of distance from the target, the measurement spot diameter is 1 unit. For example, at a distance of 12 inches, the measurement spot will be 1 inch in diameter.

To ensure accurate readings, the target object should be larger than the measurement spot. As the distance to the object increases, the measurement spot size also increases. It is recommended that the target being measured is at least twice the diameter of the thermometer's spot.

Diagram explaining the 12:1 Distance Spot Ratio (D:S) for the infrared thermometer.

Figure 5.4: Understanding Distance Spot Ratio

6. Specifications

Product standard image showing the thermometer and its packaging.

Figure 6.1: Product Standard View

AttributeValue
Model NumberTS600
TheoryMultifunctional Thermometer
Temperature Measurement Range-50℃~600℃ (-58℉-1112℉)
Max Measuring Temperature120°C & Above
Distance to Spot Ratio (D:S)12:1
EmissivityAdjustable 0.1-1.0 (Default 0.95)
Wavelength630-670nm
Response Time0.5 seconds
Power Type/Source2 x 1.5V AAA Battery (not included)
Display Size1.9 Inches & Under
Display TypeDIGITAL (LCD)
StyleHandheld
UseIndustrial
CertificationCE, RoHS
Product Dimensions (approx.)Length: 14.2 cm (5.6 in), Width: 8.6 cm (3.4 in), Depth: 4.5 cm (1.8 in)
Battery IncludedNo
High-concerned chemicalNone
Is Smart DeviceNo
Diagram showing the product dimensions in centimeters and inches.

Figure 6.2: Product Dimensions

7. Troubleshooting

ProblemPossible CauseSolution
Device does not turn on.Dead or incorrectly installed batteries.Check battery polarity and replace with fresh 1.5V AAA batteries.
Inaccurate temperature readings.Incorrect emissivity setting; target too small or too far; reflective surface; transparent material being measured.Adjust emissivity for the specific material. Ensure target is larger than the measurement spot and within optimal distance (D:S ratio). Avoid measuring through glass or liquids.
Laser not working.Laser is turned off.Short press the "Laser Aiming On/Off" button to activate the laser.
Display is dim or flickering.Low battery power.Replace batteries.

8. Maintenance

8.1 Cleaning

  • Lens: Use a soft, clean cloth or cotton swab with water or medical alcohol. Wipe gently.
  • Casing: Clean the instrument casing with a damp cloth and mild soap. Do not use abrasive cleaners or solvents.
  • Ensure the lens is clean and free of dust or debris for accurate measurements.

8.2 Storage

  • Store the thermometer in a cool, dry place when not in use.
  • Remove batteries if the device will not be used for an extended period to prevent leakage.
  • Keep out of reach of children.

9. User Tips

  • For best accuracy, always ensure the target object is larger than the measurement spot.
  • When measuring liquids, measure the surface of the liquid, not through the liquid itself.
  • Be aware of highly reflective surfaces, as they can cause inaccurate readings. Adjust emissivity or use a non-reflective tape if possible.
  • The thermometer is designed for surface temperature measurement; it is not intended for measuring internal temperatures of objects or body temperature.

10. Warranty and Support

The HYTAIS TS600 Infrared Non-Contact Thermometer is designed for reliability and durability. For any questions, technical support, or warranty claims, please refer to the contact information provided by your retailer or the manufacturer's official website.

Please retain your proof of purchase for warranty purposes.

11. Product Demonstration Video

Video 11.1: Unboxing and Basic Operation of the HYTAIS TS600 Infrared Thermometer. This video demonstrates how to unbox the thermometer, install batteries, turn the laser on/off, switch between Celsius and Fahrenheit, adjust emissivity, and set high/low temperature alarms.


HYTAIS TS600 Non-Contact Infrared Thermometer: Features & Operation Guide

HYTAIS TS600 Non-Contact Infrared Thermometer: Features & Operation Guide

1:11 • 720×960 • feature_demo
HYTAIS TS600 Digital Infrared Thermometer Unboxing & Feature Demonstration

HYTAIS TS600 Digital Infrared Thermometer Unboxing & Feature Demonstration

1:21 • 1280×720 • feature_demo

Related Documents - TS600

Preview HYTAIS TS380/TS600 Infrared Thermometer User Manual
User manual for HYTAIS TS380 and TS600 non-contact infrared thermometers, detailing features, safety instructions, operation, maintenance, and specifications for accurate surface temperature measurement.
Preview HYTAIS TS600 Digital Infrared Thermometer Gun User Manual
User manual for the HYTAIS TS600 digital infrared thermometer gun, detailing its features, operation, safety precautions, maintenance, and warranty information.
Preview HYTAIS TS-U7 Fully Automatic Recognition Multimeter User Manual
Comprehensive user manual for the HYTAIS TS-U7 Fully Automatic Recognition Multimeter. Learn about its features, specifications, operation, and safety guidelines for accurate electrical measurements.
Preview HYTAIS TS20A Pen-Type Digital Multimeter User Manual
User manual for the HYTAIS TS20A pen-type digital multimeter, detailing its features, operation, safety precautions, and specifications for measuring AC/DC voltage, resistance, and continuity.