INTNIUB STC-3028

Contents

STC-3028 Dual Digital Thermostat Temperature Humidity Controller User Manual

Model: STC-3028

1. Introduction

The STC-3028 is a versatile dual digital thermostat and hygrometer designed to simultaneously control both temperature and humidity. It is suitable for a wide range of applications such as incubators, aquariums, greenhouses, and storage facilities. This controller supports both heating/cooling and humidifying/dehumidifying equipment, offering precise environmental management.

STC-3028 controller displaying temperature and humidity, with images of applications like fish ponds, chicken coops, greenhouses, and warehouses.

Figure 1: STC-3028 Controller and typical applications.

2. Features

  • Supports temperature and humidity calibration.
  • Controls temperature and humidity simultaneously.
  • Connects with refrigeration/heating and humidifier/dehumidifier equipment.
  • Dual Display Window shows measured temperature/humidity and set temperature/humidity concurrently.
  • Heating/Cooling and Humidifying/Dehumidifying functions can be set separately to prevent rapid environmental changes.
STC-3028 controller with sensor, showing a temperature range of -20 to 80 degrees Celsius and humidity range of 0-100% RH.

Figure 2: STC-3028 Controller with sensor, highlighting its measurement ranges.

3. Setup and Installation

3.1 Unboxing

Your package should contain:

  • 1x STC-3028 Temperature Humidity Controller
  • 1x Integrated Temperature and Humidity Sensor (1m length)

3.2 Physical Installation

The STC-3028 is designed for panel mounting. Ensure adequate space for ventilation around the unit. Refer to the dimensions below for proper cutout and placement.

Diagram showing the dimensions of the STC-3028 controller: 75mm width, 34.5mm height, 85mm depth. The sensor dimensions are 71mm length and 29mm width.

Figure 3: STC-3028 Controller dimensions.

3.3 Wiring Instructions

Important Note: Always ensure power is disconnected before performing any wiring. Distinguish between sensor wiring and power wiring to prevent damage. The controller is available in AC 110-220V, DC 12V, and DC 24V versions. Ensure you use the correct power supply for your model.

STC-3028 controller, 12V version, with sensor connected.

Figure 4: STC-3028 12V variant with sensor.

STC-3028 controller, 24V version, with sensor connected.

Figure 5: STC-3028 24V variant with sensor.

STC-3028 controller, 110-220V version, with sensor connected.

Figure 6: STC-3028 110-220V variant with sensor.

Independent Load Power Wiring

This diagram illustrates wiring when the load (e.g., heater, humidifier) has its own independent power supply, separate from the controller's power supply.

Wiring diagram for STC-3028 with independent load power. Terminals 1 and 2 are for power supply (L and N). Terminals 3 and 4 are for the humidity sensor. Terminals 5 and 6 are for the temperature sensor. Terminals 7 and 8 are for the humidity load output. Terminals 9 and 10 are for the temperature load output. The diagram shows the controller's power input (L, N), sensor connections, and separate power and load connections for %RH and °C outputs.

Figure 7: Independent Load Power Wiring Diagram.

Same Load Power Wiring

This diagram illustrates wiring when the load shares the same power supply as the controller.

Wiring diagram for STC-3028 with same load power. Terminals 1 and 2 are for power supply (L and N). Terminals 3 and 4 are for the humidity sensor. Terminals 5 and 6 are for the temperature sensor. Terminals 7 and 8 are for the humidity load output. Terminals 9 and 10 are for the temperature load output. The diagram shows the controller's power input (L, N), sensor connections, and shared power and load connections for %RH and °C outputs.

Figure 8: Same Load Power Wiring Diagram.

4. Operating Instructions

4.1 Setting Startup Temperature/Humidity

  1. Press the "up" button once to display the current starting temperature (or humidity).
  2. Long press the "up" button for approximately 3 seconds until the displayed value flashes.
  3. Use the "up" and "down" keys to adjust the desired starting temperature (or humidity).
  4. The setting will automatically save after a few seconds of inactivity.

4.2 Setting Stop Temperature/Humidity

  1. Press the "down" button once to display the current stopping temperature (or humidity).
  2. Long press the "down" button for approximately 3 seconds until the displayed value flashes.
  3. Use the "up" and "down" keys to adjust the desired stopping temperature (or humidity).
  4. The setting will automatically save after a few seconds of inactivity.

4.3 Temperature/Humidity Correction

To enter the correction mode, press the "up" and "down" buttons simultaneously. Follow the on-screen prompts to adjust the calibration offset for temperature or humidity if readings are inaccurate.

5. Maintenance

  • Cleaning: Wipe the controller's surface with a soft, dry cloth. Do not use abrasive cleaners or allow liquids to enter the unit.
  • Sensor Care: Keep the temperature and humidity sensor clean and free from dust or debris. Ensure it is not exposed to direct water or extreme physical stress.
  • Calibration: Periodically check the accuracy of the readings against a known reference. If discrepancies are found, use the temperature/humidity correction feature as described in Section 4.3.

6. Troubleshooting

  • No Power: Check the power supply connection and ensure the input voltage matches the controller's specification (AC 110-220V, DC 12V, or DC 24V). Verify all wiring connections are secure.
  • Incorrect Readings: Ensure the sensor is properly connected and not damaged. Try recalibrating the temperature and humidity using the correction function.
  • Load Not Activating: Verify that the set startup and stop values are correctly configured. Check the wiring to the load (heater, humidifier, etc.) and ensure the load itself is functional.
  • Display Issues: If the display is blank or erratic, power cycle the device. If the problem persists, contact support.

7. Specifications

ParameterValue
ModelSTC-3028
Shell MaterialPC+ABS fireproof
Sensor Length1 meter
Input Voltage OptionsAC 110-220V / DC 24V / DC 12V
Measuring Temperature Range-50°C to +110°C
Measuring Humidity Range00%RH to +100%RH
Accuracy±1°C, 0.1%RH
Relay Output Contact Capacity10A/240VAC
Controller Dimensions (L x W x H)75mm x 34.5mm x 85mm
Sensor Dimensions (L x W)71mm x 29mm

8. Warranty and Support

For warranty information and technical support, please refer to the seller's policy or contact the point of purchase. Keep your purchase receipt for any warranty claims.

© 2023 INTNIUB. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.