1. Introduction

The Mestek CM87Pro is an automatic range digital clamp meter designed for professional and DIY electrical measurements. It features True RMS, Inrush current measurement, VFD, and a VA color screen, making it suitable for various applications including power maintenance, electrical installation, and industrial testing. This manual provides essential information for the safe and effective use of your CM87Pro clamp meter.

2. Safety Information

Please read and understand all safety information and operating instructions before using this instrument. Failure to do so may result in electric shock, fire, or serious injury.

  • Always adhere to local and national safety codes.
  • Do not exceed the maximum input values specified for each function.
  • Ensure the function knob is set to the correct range and function before making any measurement.
  • Inspect the test leads and the meter for any damage before use. Do not use if damaged.
  • Do not operate the meter in wet environments or with wet hands.
  • Replace batteries immediately when the low battery indicator appears to ensure accurate readings.
  • Wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves, when working with electrical circuits.
  • Avoid touching exposed wiring or circuit components while measuring.

3. Package Contents

Verify that all items listed below are included in your package. If any items are missing or damaged, please contact your retailer.

  • 1 x Mestek CM87Pro Digital Clamp Meter
  • 1 x K-type Thermocouple Probe
  • 1 x User Manual
  • 1 x Pair of Test Probes (Red and Black)
  • 1 x Instrument Storage Bag
  • 1 x Packaging Box

Video: Unboxing the Mestek CM87Pro Clamp Meter and its accessories.

Parts list for Mestek CM87Pro Clamp Meter

Image: Visual representation of the package contents, including the clamp meter, probes, thermocouple, manual, and storage bag.

4. Product Overview and Features

4.1 Appearance Introduction

Diagram of Mestek CM87Pro Clamp Meter components

Image: Detailed diagram showing the components of the Mestek CM87Pro clamp meter.

  • NCV Sensing Area: For non-contact voltage detection.
  • Current Sensing Zone: The clamp jaw for current measurement.
  • LED Lamp: Built-in flashlight for illuminating work areas.
  • Flashlight/Data Hold Key: Activates the flashlight and holds the displayed data.
  • Trigger: Opens and closes the clamp jaw.
  • Function Knob: Selects the main measurement category.
  • Function Switch Key (SEL): Cycles through multiple functions within a mode.
  • VFD/INRUSH Button: Activates Variable Frequency Drive measurement or Inrush current measurement.
  • ZERO Button: Used for zeroing DC current measurements.
  • Max/Min Switching: Toggles between maximum and minimum recorded values.
  • Display: VA color screen showing measurement readings and indicators.
  • COM (Common) Input: For connecting the black test lead.
  • INPUT: For connecting the red test lead for voltage, resistance, capacitance, frequency, diode, and continuity measurements.

4.2 Key Features

  • 1000A AC/DC Automatic Range Clamp Meter
  • True RMS for accurate measurements of non-sinusoidal waveforms.
  • Inrush Current Measurement (0-1000A)
  • VFD (Variable Frequency Drive) Measurement
  • VA Color Screen for clear readability.
  • 6000 Counting Range
  • Measures up to 1000V DC voltage and 750V AC voltage.
  • Includes K-type temperature probe for contact temperature measurement.
  • Non-Contact Voltage (NCV) Detection.
  • LIVE Wire Recognition.
  • Automatic Recognition of AC/DC Voltage (AUTO-VLOZ).
  • Large Jaw Design (42mm opening) suitable for various cable diameters.
  • Data Hold, Max/Min Measurement.
  • Backlight and Auto Power Off functions.
  • Continuity Buzzer and Diode Test.
  • Frequency and Capacitance Measurement.
Featured functions icons of Mestek CM87Pro

Image: Icons representing the various functions of the clamp meter, including AC/DC current, voltage, resistance, capacitance, diode, frequency, temperature, NCV, Live, Min/Max, Zero/Hold, VFD, Inrush, and Flashlight.

Mestek CM87Pro applications in power maintenance, electrical installation, and industrial inspection

Image: Examples of the clamp meter's use in power maintenance, electrical installation, and industrial inspection.

Mestek CM87Pro large jaw design for measuring cables

Image: Illustration of the large jaw design (30mm) suitable for measuring cables of various diameters.

5. Specifications

5.1 General Specifications

ParameterValue
Display TypeDigital Only (5999 counts)
Operating Temperature0-50 ℃
Dimensions218 x 75 x 39 mm
Weight~240g (excluding battery)
Jaw Opening42mm
Power Supply2 x 1.5V AAA batteries (Not included)
Full Range Overload Protection Voltage600V
Max Input Voltage (COM to INPUT)DC 1000V / AC 750V
Over Range DisplayOL or -OL
Sample TimeAbout 3 times per second
Automatic Shutdown TimeAbout 15 minutes
Backlight Auto Off TimeAbout 3 minutes
Flashlight Auto Shutdown TimeAbout 5 minutes
Low Battery IndicationWhen less than 2.4V
CertificationCE, FCC, RoHS

5.2 Measurement Ranges (CM87Pro)

FunctionRange
DC Current0-1000A
AC Current0-1000A
DC Voltage0-1000V
AC Voltage0-750V
Capacitance0-60mF
Resistance0-60MΩ
Frequency0-10MHZ
Inrush Current0-1000A
K-type Temperature ProbeIncluded
True-RMSYes
Data HoldYes
BacklightYes
Auto Power OffYes
NCVYes
LIVE Wire RecognitionYes
DiodeYes
Input Impedance1MΩ
Technical Parameter table for Mestek Clamp Meter

Image: Technical parameters table providing detailed specifications for the clamp meter.

6. Setup

6.1 Battery Installation

  1. Ensure the meter is powered off and all test leads are disconnected.
  2. Locate the battery compartment on the back of the meter.
  3. Open the battery compartment cover.
  4. Insert two 1.5V AAA batteries, observing the correct polarity (+/-) as indicated inside the compartment.
  5. Close the battery compartment cover securely.

6.2 Probe Connection

  • For voltage, resistance, capacitance, frequency, diode, and continuity measurements, insert the red test lead into the "INPUT" jack and the black test lead into the "COM" (Common) jack.
  • For K-type temperature measurement, connect the thermocouple probe to the designated ports on the meter.

7. Operating Instructions

7.1 Power On/Off and Function Selection

  • To power on the meter, rotate the function knob to the desired measurement mode.
  • To power off, rotate the function knob to the "OFF" position.
  • The meter features an auto power-off function after approximately 15 minutes of inactivity to conserve battery life.
  • For modes with multiple functions (e.g., Voltage AC/DC, Resistance/Diode/Continuity/Capacitance), press the "SEL" button to cycle through them.

7.2 AC/DC Current Measurement (1000A)

  1. Rotate the function knob to the AC/DC current mode.
  2. Press the trigger to open the clamp jaw.
  3. Place a single wire of the tested circuit at the center of the clamp head.
  4. Ensure the clamp is fully closed. The instrument screen will display the current value.
Measuring AC current with Mestek CM87Pro clamp meter

Image: Hand holding the clamp meter to measure AC current in a circuit.

Measuring DC current with Mestek CM87Pro clamp meter

Image: Hand holding the clamp meter to measure DC current from a car battery.

7.3 AC/DC Voltage Measurement (1000V DC / 750V AC)

  1. Connect the red test lead to the "INPUT" jack and the black test lead to the "COM" jack.
  2. Rotate the function knob to the "AUTO-V LoZ" position for automatic AC/DC voltage recognition, or to the specific AC V or DC V mode.
  3. Touch the test probes to the circuit points to be measured.
Measuring AC voltage with Mestek CM87Pro clamp meter

Image: Hand holding the clamp meter with probes measuring AC voltage (up to 750V).

Measuring DC voltage with Mestek CM87Pro clamp meter

Image: Hand holding the clamp meter with probes measuring DC voltage (up to 1000V).

Automatic recognition of AC/DC voltage (AUTO-VLOZ) on Mestek CM87Pro

Image: Demonstrating the AUTO-VLOZ feature for automatic AC/DC voltage recognition.

7.4 Resistance, Capacitance, Diode, and Continuity Measurement

  1. Connect the red test lead to the "INPUT" jack and the black test lead to the "COM" jack.
  2. Rotate the function knob to the Resistance/Diode/Continuity/Capacitance mode.
  3. Press the "SEL" button to cycle through the functions until the desired measurement unit (Ω for Resistance, F for Capacitance, Diode symbol, or Buzzer symbol for Continuity) is displayed.
  4. Touch the test probes to the component or circuit points to be measured.
Mestek CM87Pro measuring Capacitance, Resistance, Diode, and Continuity

Image: Illustrations of measuring capacitance, resistance, diode, and performing an on/off test (continuity).

7.5 Frequency Measurement

  1. Connect the red test lead to the "INPUT" jack and the black test lead to the "COM" jack.
  2. Rotate the function knob to the Hz mode.
  3. Touch the test probes to the signal source. The screen will display the frequency value and the percentage of the measured signal.
Mestek CM87Pro measuring frequency

Image: Hand holding the clamp meter with probes measuring frequency.

7.6 Temperature Measurement (K-type probe)

  1. Connect the K-type thermocouple probe to the designated ports on the meter.
  2. Rotate the function knob to the temperature mode (°C/°F).
  3. Place the thermocouple probe in contact with the object being measured.
  4. Press the "SEL" key briefly to convert between Celsius (°C) and Fahrenheit (°F).
Mestek CM87Pro performing contact temperature measurement

Image: Hand holding the clamp meter with a K-type thermocouple probe measuring temperature.

7.7 Non-Contact Voltage (NCV) Detection

  1. Rotate the function knob to the NCV mode.
  2. Bring the NCV sensing area of the instrument close to the circuit or conductor.
  3. The meter will provide different alarm prompts (audible beeps and visual indicators on the screen) according to the voltage intensity. The screen will display red for detection.
Mestek CM87Pro non-contact AC voltage detection

Image: Demonstrating NCV detection, showing low and high voltage indications on the display.

7.8 LIVE Wire Recognition

  1. Rotate the function knob to the LIVE mode.
  2. Use a test probe to touch the tested conductor.
  3. If a live wire is detected, the red backlight will illuminate, and the buzzer will sound an alarm.
Mestek CM87Pro LIVE wire recognition

Image: Hand using a probe for live wire recognition, with the red backlight indicating a live circuit.

7.9 Inrush Current Measurement

  1. Rotate the function knob to an AC current measurement mode.
  2. Before measuring, ensure the load power supply is disconnected.
  3. Press and hold the "INRUSH" button.
  4. Connect the load power supply. The meter will measure the peak current when the machine starts.
Mestek CM87Pro surge current measurement (Inrush)

Image: Diagram illustrating surge current measurement and a hand using the meter for inrush current measurement.

7.10 Zeroing Function (DC Current)

  1. In DC current measurement mode, ensure the clamp jaw is closed and not clamping any conductor.
  2. Long press the "ZERO" key.
  3. This eliminates any base number caused by magnetic field interference in the usage environment, providing more accurate measurement results.
Mestek CM87Pro DC current reset to zero

Image: Comparison of DC current reading before and after resetting to zero.

7.11 Data Hold (HOLD button)

  1. During any measurement, short press the "HOLD" key to lock the current data on the display.
  2. The buzzer will sound a warning every 2 seconds to remind you that data is currently in a locked state.
  3. Press "HOLD" again to release the data and resume live measurement.
Mestek CM87Pro data hold function

Image: Illustration of the data hold function, showing a locked reading on the display.

7.12 MAX/MIN Measurement

  1. During AC/DC voltage or AC/DC current measurement, press the "MAX/MIN" button.
  2. The meter will start recording the maximum and minimum values.
  3. Press the button again to cycle between MAX, MIN, and current readings.
Mestek CM87Pro MAX/MIN measurement and flashlight

Image: Demonstrating MAX/MIN measurement and the flashlight feature.

7.13 Flashlight

  • Press the dedicated flashlight button (often combined with the Data Hold key) to turn the built-in LED light on or off. This is useful for illuminating dark work areas.

8. Maintenance

8.1 Cleaning

  • Wipe the meter with a dry, soft cloth.
  • Do not use abrasive cleaners or solvents, as they may damage the casing or display.

8.2 Battery Replacement

  • Replace batteries when the low battery indicator appears on the display.
  • Ensure the meter is powered off and all test leads are disconnected before opening the battery compartment.
  • Follow the battery installation steps outlined in Section 6.1.

8.3 Storage

  • Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
  • If storing for extended periods (more than one month), remove the batteries to prevent leakage and damage to the meter.

9. Troubleshooting

  • No display/Meter won't turn on: Check the batteries. Ensure they are correctly inserted and sufficiently charged. Replace if necessary.
  • Inaccurate readings: Verify that the test leads are properly connected and undamaged. Ensure the correct function and range are selected for the measurement. For DC current, perform the zeroing function if needed. Check for strong electromagnetic interference in the environment.
  • Low battery indicator: Replace the batteries immediately to ensure continued accurate operation.
  • "OL" or "-OL" on display: This indicates that the measured value exceeds the selected range. Switch to a higher measurement range if available, or confirm that the value is truly out of the meter's maximum capacity.

10. User Tips

  • The CM87Pro model is capable of measuring up to 1000V DC and 750V AC, and includes temperature measurement capabilities. Always be mindful of these limits and select the appropriate function.
  • Utilize the backlight feature in dimly lit environments for better readability of the VA color screen.
  • The auto-ranging feature simplifies operation, but always double-check the displayed units and magnitude for correctness.

11. Warranty and Support

For warranty information and technical support, please refer to the official MESTEK website or contact your point of purchase. Keep your purchase receipt or proof of purchase for any warranty claims.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.