1. Introduction
This 4-in-1 multifunctional beauty machine combines 40KHz cavitation, Radio Frequency (RF), and vacuum suction technologies to provide comprehensive body slimming, fat burning, and skin tightening treatments. It is designed for use on various body parts including the face, arms, abdomen, thighs, back, waist, and buttocks.
Working Principles:
- 40KHz Cavitation: Emits ultrasonic waves to vibrate fat cells at high speed, promoting cell motivation and effectively reducing fat deposits.
- Radio Frequency (RF): Utilizes RF energy to facilitate the excretion of integrated glycerol and free fatty acids through hepatoenteral circulation. It also stimulates collagen production to tighten and firm the skin.
- Vacuum RF: Focuses RF energy on specific areas, combined with vacuum suction, to reduce fat, accelerate metabolism, relieve muscle fatigue, and tighten skin by delivering thermal energy.
2. Specifications
| Attribute | Value |
|---|---|
| Item Type | 4 in 1 Cavitation Machine |
| Model Number | LT-102 40K Cavitation Ultrasonic |
| Brand Name | vilnason |
| Product Material | ABS+PC+Metal |
| Power Input Voltage | 110 - 240V |
| Power Output Voltage | 24V |
| Power Output Current | 2A |
| Total Instrument Power | 50W |
| Cavitation Head Frequency | 40kHz |
| RF Output Frequency | 5mHz |
| Application | BODY |
| Certification | CE |
| Origin | Mainland China |
3. Package Contents
Please check the box for the following items:
- 1 x Main machine
- 1 x Vacuum RF head
- 1 x 40kHz cavitation head
- 1 x 3-pole RF head
- 1 x 4-pole RF head
- 1 x Power Adapter
- 1 x Rack for handles
- 1 x User Manual
4. Assembly and Setup
Follow these steps to assemble and set up your machine:
- Install Filter Cotton: Carefully install the filter cotton into the designated handle.
- Mounting Bracket: Attach the mounting bracket to the main machine to hold the treatment heads.
- Connect Handles: Connect each treatment head (Vacuum RF, 40kHz Cavitation, 3-pole RF, 4-pole RF) to its corresponding port on the main machine. Ensure the bayonet is upward when connecting the negative pressure handle.
- Connect Power: Connect the power adapter to the main machine and then plug it into a suitable power outlet. Turn the power lamp on.
Video: Product Assembly and Basic Operation Guide. Shows installing filter cotton, mounting the bracket, connecting handles, and powering on the device.

Image: Overview of the assembled 4-in-1 Cavitation Machine with all components connected.

Image: Rear view of the main unit, highlighting the power interface and controls for negative pressure intensity.
5. Operation Guide
General Operation Steps:
- Clean the skin area to be treated.
- Apply a suitable gel or essential oil to the skin.
- Ensure the desired treatment head is securely connected to the main machine.
- Turn on the machine and select the appropriate mode for the connected head on the display screen.
- Adjust the intensity and treatment time as needed.
- Press "Start" to begin the treatment.
- Apply the treatment head to the skin and move it gently over the target area.
Specific Handle Functions and Application Areas:

Image: Detailed view of each treatment handle, outlining their specific uses and benefits.
- Tri-pole RF Handle:
Treatment areas: Face, especially skin around eyes, nose, and mouth.
Functions: Reduces crow's feet, dark circles, under-eye bags, and lifts skin. - Quadru-pole RF Handle:
Treatment areas: Face, neck.
Functions: Lifts and firms skin, reduces facial wrinkles and neck lines, increases skin elasticity. - Vacuum RF Handle:
Treatment areas: Arms, legs, abdomen, belly, back, waist, etc.
Functions: Reduces local fat, improves blood circulation and lymphatic detox, firms skin, increases skin elasticity. - 40K Cavitation Handle:
Treatment areas: Arms, legs, abdomen, belly, back, waist, etc.
Functions: Reduces local fat, improves blood circulation and lymphatic detox.
Recommended Usage:
It is recommended to use the machine for 15 to 30 minutes per session, three times a week.

Image: Display screen interface, illustrating options for Cavitation 40K, Tripolar RF, Multipolar RF, and Vacuum R.F. modes with time and intensity settings.
6. Maintenance
- Always clean the skin area before treatment.
- After each use, clean the treatment heads with a wet cotton cloth or towel. Do not use disinfectant.
- If the machine has been used continuously for 1 hour, stop operation and allow it to cool down for 10 minutes before resuming use.
7. Troubleshooting
Common Issues:
- Tinnitus when using the cavitation head: This is a normal phenomenon. The cavitation head operates at a wave band that may exceed the human hearing range, causing a temporary ringing sensation. This is not indicative of a malfunction.
8. Safety Warnings
- Always apply a water-based medium (such as slim essential oil or conductive gel) to the skin before using the machine. Failure to do so may cause damage to the instrument.
- Do not keep the operating heads in one skin area for too long. Move the heads continuously to avoid discomfort or adverse effects.
- Avoid using the machine directly over areas with bones.
- Both the operator and the person receiving the treatment should remove all metal decorations from their body before use.
- You can adjust the intensity level to suit your comfort and needs. However, it is strongly recommended to start from the lowest intensity level and gradually increase it.
9. User Tips
No specific user tips from buyer reviews or Q&A were provided for this product.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact details provided by your retailer or the manufacturer's official website.