POXURIO 3450-Watt Dual Fuel Inverter Generator

Rate this product if you’ve used it
Contents

POXURIO 3450-Watt Dual Fuel Inverter Generator Instruction Manual

Model: 3450-Watt Dual Fuel Inverter Generator

Introduction

This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your POXURIO 3450-Watt Dual Fuel Inverter Generator. Please read this manual thoroughly before operating the generator to ensure proper use and to prevent injury or damage.

The POXURIO 3450-Watt Dual Fuel Inverter Generator is designed to provide reliable emergency power for home use, outdoor activities, camping, and commercial applications. Featuring advanced sound reduction technology, it operates quietly, making it suitable for various environments. Its dual-fuel capability allows operation on either gasoline or propane, offering flexibility and convenience.

Safety Information

DANGER: CARBON MONOXIDE HAZARD

Using a generator indoors CAN KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use in an enclosed area or partially enclosed area, even if doors and windows are open.

Always operate the generator outdoors in a well-ventilated area, far away from windows, doors, and vents. Install battery-operated carbon monoxide alarms in your home and check them regularly.

  • Read and understand all safety warnings and instructions before use.
  • Keep children and pets away from the generator during operation.
  • Do not refuel the generator while it is running or hot. Allow it to cool down before adding fuel.
  • Ensure proper grounding of the generator before connecting any electrical devices.
  • Do not operate the generator in wet conditions or expose it to rain.
  • Always use the correct type of fuel and oil as specified in the manual.

Product Features

  • Strong Power Output: 3450W starting power, capable of meeting daily needs for various electrical appliances and equipment.
  • Low Noise Operation: Advanced sound reduction technology results in a noise level of only 66 decibels, significantly quieter than traditional generators.
  • Dual Fuel Capability: Operates on both traditional gasoline and propane, providing versatile fuel options.
  • Parallel Operation Support: Allows connection of 2 or 3 inverter generators to achieve combined power output exceeding 3450W. Features excellent current stability to protect sensitive electronic equipment.
  • Lightweight and Portable: Weighs only 46.3 pounds, making it easy to carry and store for outdoor camping, emergency situations, and other portable power needs.
  • Large Fuel Capacity: Upgraded 1.6 Gallon (6L) fuel tank allows for up to 8.3 hours of continuous use at 25% load.
  • Easy Start Dial: Simplified starting procedure with a dedicated dial for ON/OFF and FUEL ON.
  • Multiple Outlets: Includes AC 120V and DC 12V outlets for various power requirements.

Specifications

POXURIO 3450-Watt Dual Fuel Inverter Generator with dimensions

Image: POXURIO 3450-Watt Dual Fuel Inverter Generator showing dimensions and key features.

FeatureSpecification
Starting Power3450 Watts
Rated Voltage120V
Rated Frequency60Hz
Rated Speed4800 RPM
Engine Displacement121.6cc
Fuel TypeGasoline, Propane (Dual Fuel)
Fuel Tank Capacity1.6 Gallons (6 Liters)
Run Time (at 25% load)Up to 8.3 Hours
Noise Level66 Decibels
Weight46.3 lbs
Dimensions (L x W x H)19.3" x 11.8" x 19.3"
POXURIO 3450-Watt Dual Fuel Inverter Generator showing fuel capacity and run time

Image: Generator highlighting 6L fuel capacity and 8.3 hours run time at 25% load.

Setup

Before first use, ensure the generator is placed on a flat, stable surface outdoors in a well-ventilated area.

  1. Add Engine Oil: Remove the oil fill cap/dipstick. Add the recommended engine oil (refer to the oil type and capacity in the full user manual if available). Do not overfill.
  2. Add Fuel:
    • Gasoline: Open the fuel cap and carefully pour fresh, unleaded gasoline into the fuel tank. Do not fill above the maximum fill line. Securely close the fuel cap.
    • Propane: Connect a propane tank to the generator's propane inlet using the appropriate hose and regulator (sold separately or included). Ensure all connections are tight.
  3. Check Air Filter: Ensure the air filter is clean and properly installed.
  4. Connect Grounding Wire: If required by local regulations, connect a grounding wire to the generator's grounding terminal and a suitable ground source.
POXURIO 3450-Watt Dual Fuel Inverter Generator control panel and easy start dial

Image: Generator showing the Easy Start Dial and control panel with outlets.

Operating Instructions

Starting the Generator (Gasoline)

  1. Ensure the generator is outdoors and away from any combustible materials.
  2. Turn the "EASY START DIAL" to the "FUEL ON" position.
  3. If the engine is cold, apply choke (refer to the full manual for choke lever location if not integrated into the dial).
  4. Pull the recoil start handle firmly and smoothly until the engine starts.
  5. Once the engine starts, slowly move the choke to the "RUN" position (if applicable).
  6. Allow the generator to run for a few minutes before connecting electrical loads.

Starting the Generator (Propane)

  1. Ensure the propane tank is connected securely and the valve is open.
  2. Turn the "EASY START DIAL" to the "FUEL ON" position.
  3. If the engine is cold, apply choke (refer to the full manual for choke lever location if not integrated into the dial).
  4. Pull the recoil start handle firmly and smoothly until the engine starts.
  5. Once the engine starts, slowly move the choke to the "RUN" position (if applicable).
  6. Allow the generator to run for a few minutes before connecting electrical loads.

Connecting Electrical Loads

  • Plug your electrical devices into the appropriate AC 120V or DC 12V outlets on the control panel.
  • Do not overload the generator. Ensure the total wattage of connected devices does not exceed the generator's running wattage.

Parallel Operation

This generator supports parallel operation to double or triple the power output. To connect two generators in parallel:

  1. Ensure both generators are turned off and cooled down.
  2. Connect the parallel kit (sold separately) to the designated parallel ports on both generators.
  3. Start both generators according to the instructions above.
  4. Once both generators are running stably, you can connect your electrical loads to the parallel kit's outlets.
  5. Refer to the parallel kit's instruction manual for detailed connection and operation procedures.
Two POXURIO inverter generators connected for parallel operation

Image: Two generators demonstrating parallel capability for increased power.

Stopping the Generator

  1. Disconnect all electrical loads from the generator.
  2. Turn the "EASY START DIAL" to the "OFF" position.
  3. If using propane, close the valve on the propane tank.
  4. Allow the generator to cool down completely before storing.

Maintenance

Regular maintenance ensures the longevity and optimal performance of your generator. Always perform maintenance when the generator is off and cooled down.

  • Check Oil Level: Before each use, check the engine oil level and add if necessary.
  • Change Oil: Change the engine oil after the first 20 hours of operation, and then every 100 hours or annually, whichever comes first.
  • Clean Air Filter: Inspect the air filter regularly and clean or replace it if it's dirty. A clogged air filter can reduce engine performance.
  • Inspect Spark Plug: Check the spark plug for wear and carbon buildup. Clean or replace as needed.
  • Inspect Fuel Filter: Check the fuel filter for debris and replace if necessary.
  • Clean Exterior: Keep the generator's exterior clean and free of debris.
  • Storage: For long-term storage, drain the fuel tank and carburetor (for gasoline) or disconnect the propane tank. Store in a dry, well-ventilated area.

Troubleshooting

ProblemPossible CauseSolution
Engine will not startNo fuel, low oil, choke not set, spark plug issue, fuel valve offAdd fuel, add oil, set choke, check/replace spark plug, open fuel valve
No power outputOverload, circuit breaker tripped, Eco-mode engagedReduce load, reset circuit breaker, disengage Eco-mode (if applicable)
Engine runs roughStale fuel, dirty air filter, spark plug issueUse fresh fuel, clean/replace air filter, check/replace spark plug
Excessive noiseLoose components, exhaust issueCheck for loose parts, inspect exhaust system

For more detailed troubleshooting, please refer to the complete user manual or contact customer support.

Warranty and Support

Your POXURIO 3450-Watt Dual Fuel Inverter Generator comes with a manufacturer's warranty. Please refer to the warranty card included with your product for specific terms and conditions, including coverage duration and claim procedures.

For technical assistance, parts, or warranty claims, please contact POXURIO customer support through the retailer where you purchased the product or visit the official POXURIO website for contact information.

Keep your purchase receipt and serial number handy when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?