The Hantek DSO2D15 is a versatile 2-channel digital storage oscilloscope combined with a 25MHz arbitrary waveform signal generator. It offers a 150MHz analog bandwidth and a 1GSa/s real-time sample rate, making it suitable for a wide range of electronic testing and measurement applications. This manual provides essential information for setting up, operating, and maintaining your device.

Hantek DSO2D15 Oscilloscope with waveform display
Figure 1: Hantek DSO2D15 Oscilloscope with a displayed waveform, highlighting 2 channels, 150MHz bandwidth, and AWG function.

2. Package Contents

Before proceeding, please verify that all items listed below are included in your package:

  • 1 x Hantek DSO2D15 Digital Oscilloscope
  • 2 x BNC to Crocodile Clip Test Lines
  • 1 x Oscilloscope Test Probe
  • 1 x USB Cable
  • 1 x Power Cord (region specific)
  • 1 x English User Manual
Hantek DSO2D15 Oscilloscope and included accessories
Figure 2: Hantek DSO2D15 Oscilloscope with included accessories.

3. Setup

3.1 Physical Overview

Front view of Hantek DSO2D15 Oscilloscope
Figure 3: Front view of the Hantek DSO2D15 Digital Oscilloscope, showing the display and control panel.
Rear view of Hantek DSO2D15 Oscilloscope
Figure 4: Rear view of the Hantek DSO2D15 Oscilloscope, showing power input, USB port, and warning labels.

3.2 Power Connection

  1. Connect the provided power cord to the AC power inlet on the rear panel of the oscilloscope.
  2. Plug the other end of the power cord into a suitable AC power outlet.
  3. Press the power button on the front panel to turn on the device.

3.3 Probe Connection

  1. Connect the oscilloscope test probe to one of the BNC input channels (CH1 or CH2) on the front panel.
  2. Ensure the probe is securely twisted into place.
  3. Set the probe attenuation switch (if present) to the desired setting (e.g., 1X or 10X) and adjust the oscilloscope's probe setting accordingly in the menu.
  4. For the arbitrary waveform generator (AWG) function, connect the BNC to crocodile clip test lines to the AWG output and to your circuit under test.

4. Operating Instructions

4.1 Basic Oscilloscope Functions

The DSO2D15 features 2 independent channels, 150MHz bandwidth, 1GSa/s real-time sample rate, and 8M memory depth. Vertical range is 2mV/div to 10V/div with 8-bit vertical resolution.

  • Channel Control: Each channel (CH1, CH2) has independent knobs for vertical position and volts/div settings.
  • Horizontal Control: Use the horizontal position and sec/div knobs to adjust the time base.
  • Trigger System: Supports various trigger types including Edge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Delay, UART, LIN, CAN, SPI, IIC.
  • Measurements: Offers 32 kinds of auto measurements with statistics (maximum, minimum, standard deviation, etc.). Includes 5-bit digital voltage meter and 6-bit hardware frequency indicator.
  • Data Saving: Can save data in multiple formats: setting, waveform, reference waveform, CSV, and picture.
Oscilloscope display with sine wave and measurements
Figure 5: Oscilloscope display showing a sine wave with various measurement parameters.
Oscilloscope display showing sine wave measurements
Figure 6: Oscilloscope display showing a sine wave with various measurement parameters like frequency, peak-to-peak voltage, rise time, and fall time.
Dual channel Lissajous pattern
Figure 7: Oscilloscope display showing two sine waves and a Lissajous pattern, indicating dual-channel operation.
Dual channel DC RMS voltage measurements
Figure 8: Oscilloscope display showing two waveforms with DC RMS voltage measurements.

4.2 Arbitrary Waveform Generator (AWG)

The DSO2D15 includes a built-in 1-channel 25MHz arbitrary waveform generator with a 200MSa/s sample rate and 12-bit vertical resolution.

  • Waveform Generation: Generate standard waveforms (sine, square, ramp, pulse) and custom arbitrary waveforms.
  • Frequency & Amplitude: Adjust output frequency up to 25MHz and amplitude as needed.
Arbitrary waveform generator output
Figure 9: Oscilloscope display showing an arbitrary waveform generator output (sine wave at 25MHz) with amplitude and offset settings.

4.3 Advanced Features

  • Protocol Analysis: Supports CAN decode and protocol analysis for RS232/UART, I2C, SPI, CAN, LIN.
  • Threshold Testing: Allows for free measurements within the screen and supports threshold testing.
  • FFT Analysis: Perform Fast Fourier Transform analysis for frequency domain measurements.
  • Remote Control: Abundant SCPI remote command control for automation.
  • External Interface: USB Host/Device for data transfer and connectivity.
Threshold testing display
Figure 10: Oscilloscope display demonstrating threshold testing with pass/fail waveform counts.
FFT analysis display
Figure 11: Oscilloscope display showing FFT (Fast Fourier Transform) analysis of a signal.
IIC protocol decoding display
Figure 12: Oscilloscope display showing IIC (I2C) protocol decoding.
UART protocol decoding display
Figure 13: Oscilloscope display showing UART protocol decoding.
CAN protocol decoding display
Figure 14: Oscilloscope display showing CAN protocol decoding.

5. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp cloth with mild detergent can be used. Avoid abrasive cleaners or solvents.
  • Probe Care: Handle probes carefully. Avoid bending or stressing the probe tips. Store probes properly to prevent damage.
  • Ventilation: Ensure the ventilation openings on the device are not blocked to prevent overheating.
  • Storage: When not in use for extended periods, store the oscilloscope in a dry, dust-free environment.

6. Troubleshooting

  • No Power: Check the power cord connection and the power outlet. Ensure the power button is pressed.
  • No Signal Display: Verify probe connections to both the oscilloscope and the circuit under test. Check the channel input settings (e.g., AC/DC coupling, vertical scale). Ensure the trigger level is set correctly.
  • Distorted Waveform: Check probe compensation. Ensure the probe attenuation setting matches the oscilloscope's setting. Verify the input signal is within the oscilloscope's voltage limits.
  • AWG Output Issues: Confirm the AWG function is enabled and the correct waveform parameters are set. Check the connection of the BNC to crocodile clip test lines.

7. Specifications

Below are the detailed specifications for the Hantek DSO2D15 model:

Detailed specifications table for Hantek oscilloscopes
Figure 15: Detailed specifications table for DSO2D15 and related models.
FeatureSpecification (DSO2D15)
Channel2 CH
Bandwidth150MHz
Sample Rate1GSa/S
Memory Depth8M
Vertical Range2mV/div ~ 10V/div
Vertical Resolution8bit
AWG Channel1 CH
AWG Max Frequency25MHz
AWG Sample Rate200MSa/s
AWG Vertical Resolution12 bits
Trigger TypesEdge, Pulse width, Video, Slope, Overtime, Window, Pattern, Interval, Delay, UART, LIN, CAN, SPI, IIC
Decoding & AnalysisRS232/UART, I2C, SPI, CAN, LIN
External InterfaceUSB Host/Device
Dimensions (approx.)318mm (L) x 140mm (W) x 150mm (H)
Side view of Hantek DSO2D15 with dimensions
Figure 16: Side view of the Hantek DSO2D15 Oscilloscope with dimensions.

8. User Tips

  • Probe Compensation: Always perform probe compensation before making critical measurements to ensure accurate readings.
  • Grounding: Ensure proper grounding of the oscilloscope and the circuit under test to avoid noise and ensure safety.
  • Firmware Updates: Check the manufacturer's website periodically for firmware updates to ensure optimal performance and access to new features.
  • SCPI Commands: For advanced users, familiarize yourself with SCPI commands for automated testing and integration with other systems.

9. Warranty and Support

Hantek products typically come with a manufacturer's warranty. Please refer to the warranty card included in your package or visit the official Hantek website for detailed warranty terms and conditions. For technical support, troubleshooting assistance, or service inquiries, please contact Hantek customer service directly through their official channels.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.