EVCO Temperature Controller and Communication Card Instruction Manual
Models: EV3X21N7, EVKB21N7, EVK401N7, EV3B23N7, EVIF20TSXS
Brand: EVCO
1. Introduction
This manual provides essential information for the proper installation, operation, and maintenance of EVCO Temperature Controllers and the EVIF20TSXS Communication Card. Please read this manual carefully before using the product to ensure safe and efficient operation.
Note: EVKB23N7 has been replaced by EV3B23N7. EVKB21N7 has been replaced by EV3X21N7.
2. Product Overview
The EVCO Temperature Controllers are designed for precise temperature management in various applications. The EVIF20TSXS Communication Card enables network connectivity for these controllers.
2.1 Controller Features
- Digital display for temperature readings and settings.
- Intuitive button interface for configuration.
- Compact design for easy integration.

2.2 Communication Card Features
- RS-485 network interface for communication.
- Designed for seamless integration with EVCO instruments.

3. Setup and Installation
Installation should be performed by qualified personnel in accordance with local electrical codes and regulations.
3.1 Wiring the Temperature Controller (e.g., EVKB21N7)
Refer to the wiring diagram on the back of the unit for correct connections. Ensure the power supply matches the unit's requirements (e.g., 230 VAC).

Key Connections:
- Power Supply: Connect to terminals 1 and 2 (e.g., 230 VAC).
- Compressor (COMP): Connect to terminals 3, 4, and 5.
- Measure Input (NTC): Connect the NTC sensor to the designated terminals.
- EVKEY (Optional): Connect to terminals 10 and 11.
- CAB.DIG.: Connect to terminal 12.

3.2 Wiring the EVIF20TSXS Communication Card
The communication card connects to the instrument and the RS-485 network.
Key Connections:
- NETWORK (RS-485): Connect the RS-485 communication lines to terminals S, +, and -.
- TO THE INSTRUMENT: Connect the card to the EVCO temperature controller using the designated port.
4. Operating Instructions
The EVCO Temperature Controllers typically feature a digital display and several buttons for operation.
4.1 Basic Operation
- Power On/Off: Press the power button (usually marked with a circle and vertical line) to turn the unit on or off.
- Set Temperature: Press the 'set' button to enter the temperature setting mode. Use the up/down arrow buttons to adjust the desired temperature. Press 'set' again to confirm.
- View Parameters: Use the arrow buttons to scroll through various parameters displayed on the screen.

4.2 Advanced Settings
Consult the specific model's detailed manual for advanced parameter settings, calibration, and alarm configurations. These settings often involve holding down specific buttons or entering a programming menu.
5. Maintenance
Regular maintenance ensures the longevity and accuracy of your EVCO products.
- Cleaning: Clean the unit's exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Sensor Check: Periodically check the temperature sensor for damage or corrosion. Ensure it is securely connected.
- Wiring Inspection: Inspect all wiring connections for tightness and signs of wear or damage.
- Environmental Conditions: Ensure the operating environment remains within the specified temperature and humidity ranges to prevent damage.
6. Troubleshooting
If you encounter issues, refer to the following common problems and solutions:
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is blank | No power, incorrect wiring | Check power supply, verify wiring connections. |
| Incorrect temperature reading | Faulty sensor, sensor disconnected, incorrect calibration | Check sensor connection, replace sensor if faulty, recalibrate if necessary. |
| Controller not responding to settings | Locked keypad, internal fault | Unlock keypad (refer to specific model manual), power cycle the unit. If problem persists, contact support. |
| Communication card not connecting | Incorrect RS-485 wiring, incorrect communication settings | Verify RS-485 wiring (S, +, -), check communication parameters (baud rate, address). |
7. Specifications
| Feature | Specification |
|---|---|
| DIY Supplies | Electrical |
| Origin | Mainland China |
| High-concerned chemical | None |
| Certification | NONE |
| Power Supply (EVKB21N7) | 230 VAC |
| Measure Input (EVKB21N7) | NTC (-40.0 to 105.0°C, -40 to 220°F) |
| Communication (EVIF20TSXS) | RS-485 Network |
| EVIF20TSXS Serial Number (example) | SX78658 |
| EVIF20TSXS Ambient Temperature (ta) | OT55 |
8. User Tips
- For optimal performance, ensure the temperature sensor is placed in a location that accurately reflects the temperature you wish to control, away from direct heat sources or drafts.
- When replacing older models like EVKB23N7 or EVKB21N7, ensure you use the recommended replacements (EV3B23N7 and EV3X21N7 respectively) to maintain compatibility and functionality.
- Always double-check wiring connections before applying power to prevent damage to the unit or connected equipment.
9. Support
For further assistance, technical support, or inquiries regarding specific model functionalities, please refer to the official EVCO documentation or contact an authorized service provider.
10. Product Video Overview
Watch this short video for a general overview of the product.