1. Introduction
1.1. Product Overview
The JIKONG Lithium battery intelligent protection board is a management system tailored for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge, over-temperature protection, coulomb meter, Bluetooth communication, and GPS remote functions. It is compatible with lithium iron phosphate, ternary lithium, and lithium titanate battery types.
This protection board utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 1A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and delays battery aging.
A mobile APP supporting Android and iOS is available. The APP connects via Bluetooth to monitor battery status, modify parameters, and control charge/discharge switches. The compact design, simple operation, and comprehensive functions make it suitable for various applications including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage, base station backup power, and solar power stations.

1.2. Functional Characteristics
The JIKONG Smart BMS offers a wide range of functional characteristics to ensure optimal battery performance and safety:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support heating function (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support GPS communication (Optional)
- Discharge precharge function (Optional)
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection

2. Specifications
2.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 10-36 | V |
| Operating Power Consumption | <900 | mW |
| Operating Temperature | -30-70 | °C |
| Maximum Number of Collection Strings | 8 | String |
| Maximum Balancing Current | 1 | A |
| Maximum Charging Current | 100 | A |
| Maximum Discharge Current | 100 | A |
| Maximum Instantaneous Current | 200 | A |
| Maximum Internal Loop Resistance | 0.8 | mΩ |
| Protective Plate Size | 153.9*107*17.6 | mm |
| Finished Weight | 411 | g |
2.2. Default Parameters
| Parameter | Li-ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Maximum Balancing Current | 1 | 1 | 1 | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-Circuit Protection Delay | 1500 | 1500 | 1500 | uS |
| Short Circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection Temperature | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery Temperature | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection Temperature | -20 | -20 | -20 | °C |
| Charge Low Temperature to Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection Temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature Protection Recovery Temperature | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
| Discharge Precharge Time | 0 | 0 | 0 | S |
2.3. Product Dimensions
The JK-B1A8S-10P series protection board has overall dimensions of 153.9mm x 107mm x 17.6mm.

3. Package Contents
The standard package for the JIKONG Smart BMS includes the following items:
- BMS unit: 1
- NTC temperature sensor (400mm): 1
- Balance Wires (750mm): 1
- Switch (500mm): 1
- Packing box: 1
- M6 screws: 2

4. Installation
4.1. Product Appearance and Interfaces




Interface Definitions
| Connector | Pin | Name | Definition |
|---|---|---|---|
| P1 (XH-10AW-2.54 Balance with Acquisition interface) | 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive | |
| 3 | B2 | The second battery positive | |
| 4 | B3 | The third battery positive | |
| 5 | B4 | The fourth battery positive | |
| 6 | B5 | The fifth battery positive | |
| 7 | B6 | The sixth battery positive | |
| 8 | B7 | The seventh battery positive | |
| 9 | B8 | The eighth battery positive | |
| 10 | B+ | Protection board power supply, connected to the battery | |
| P2 (A1254WF-6A Display interface) | 1 | VCC | Display power output |
| 2 | A | The display RS485 signal is positive | |
| 3 | B | The display RS485 signal is negative | |
| 4 | GND | Negative terminal | |
| 5 | K+ | Activate the positive signal | |
| 6 | K- | Activation signal negative electrode | |
| P3 (HY2.0-4P Temperature interface) | 1 | TIA | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B | |
| 3 | T2A | Second temperature sensor pin A | |
| 4 | T2B | Second temperature sensor pin B | |
| P4 (HY2.0-4P 4 external optional Temperature interface) | 1 | T3A | Third temperature sensor pin A |
| 2 | T3B | Third temperature sensor pin B | |
| 3 | T4A | Fourth temperature sensor pin A | |
| 4 | T4B | Fourth temperature sensor pin B | |
| P5 (A1254WF-2A Optional Buzzer interface) | 1 | VCC | Buzzer power supply positive |
| 2 | GND | Buzzer power supply negative | |
| P6 (1.25T-4PWT GPS interface) | 1 | VGPS | Power output, the voltage is close to B+ |
| 2 | TX | UART TX, 3.3V | |
| 3 | RX | UART RX, 3.3V | |
| 4 | GND | Power/signal ground | |
| P7 (A1254WF-4A Optional Communication interface) | 1 | RS485 B | Negative terminal of RS485 signal |
| 2 | RS485 A | RS485 signal positive terminal | |
| 3 | CAN H | CAN signal positive terminal | |
| 4 | CAN L | CAN signal negative terminal | |
| P8 (A1254WF-3A Optional Parallel interface) | 1 | GND | Signal ground |
| 2 | P-EN | Parallel module enable signal, output low level Turn on parallel module | |
| 3 | P-status | Parallel module status signal | |
| Heating wire (16AWG-Orange-15CM Optional) | 1 | HT- | Heater element negative electrode |
| D1 | Bluetooth connection indicator: When Bluetooth is connected to the protection board, the indicator is steady on, and when the connection is disconnected, the indicator is blinking. | ||
| P- | Connect to external load or negative terminal of charger, equipped with M6 screws. | ||
| B- | Connect to the negative battery terminal, equipped with M6 screws. | ||
4.2. Wiring Diagram
The JK-B1A8S-10P series protection board is suitable for 3-8 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack, as shown in the diagram below. Ensure all connections are correct before powering on.

5. Operation
5.1. Device Activation
Before powering on the protection board, verify that the balance cable is properly connected and that P- and B- are correctly wired. Ensure the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or damage. The protection board does not have a power-on switch; it is designed for charging activation. After battery assembly, connect the charger (with voltage 2V higher than battery voltage) to activate the board. The board also supports activation via a button or display screen for users with these optional features.
5.2. APP Installation and Usage
The mobile APP for the JIKONG BMS can be obtained by scanning the QR code in the official user manual PDF. An Android device with version 7 or higher is required.
The APP allows you to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth.

5.3. Functional Descriptions
Active Equalization
The BMS uses active equalization to transfer energy from higher-voltage cells to lower-voltage cells, ensuring battery consistency. Users can set the balance trigger voltage difference (mV) in the APP. The default balance current is 1A, adjustable based on battery capacity (recommended not to exceed 0.2C). The balancing function automatically activates when the voltage difference exceeds the set value and deactivates when it falls below.
GPS and Display Interface
The protection board includes reserved GPS and display interfaces. Users can connect optional GPS devices for battery location tracking and external display screens to view battery information.

Heating Function (Optional)
For low-temperature environments, an optional heating function can be used with resistance heaters or heating films to prevent reduced battery activity. The designed heating current is 4A. Users can control this function via the APP. A temperature control switch (45°C-65°C normally closed) is recommended as a secondary protection.
Alarm Function (Optional)
The optional alarm function provides external alerts when the BMS detects safety risks such as over-temperature, overcharge, or over-discharge.
Battery Pack Parallel Function (Optional)
The optional parallel function allows multiple battery packs to be used together, suitable for energy storage applications. This function requires synchronous use with parallel modules and disabling 'charging current limiting' in the APP.
Overvoltage Protection (Charge)
The BMS includes standard charge overvoltage protection. Users can set individual cell overcharge protection and recovery voltages in the APP. If any cell exceeds the set overvoltage, charging will stop until all cell voltages fall below the recovery voltage.
Undervoltage Protection (Discharge)
Standard discharge undervoltage protection is included. Users can set undervoltage protection, recovery, and automatic shutdown voltages in the APP. If any cell falls below the set undervoltage, discharge will stop. Discharge resumes when all cells are above the recovery voltage. If any cell reaches the automatic shutdown voltage, the board will shut down.
Overcurrent Protection (Charge & Discharge)
Standard charge and discharge overcurrent protection is provided. Users can set continuous current, overcurrent delay, and recovery times in the APP. If the current exceeds the set value for the specified delay, protection activates, stopping charge/discharge. Operation resumes after the recovery time. (Note: Maximum continuous discharge current should not exceed 100A).
Overtemperature Protection (Charge & Discharge)
Standard charge and discharge overtemperature protection is included. Users can set protection and recovery temperatures in the APP. If the temperature exceeds the set value, charge/discharge stops until the temperature falls below the recovery value.
Low Temperature Protection (Charge)
Standard charge low temperature protection is included. Users can set protection and recovery temperatures in the APP. If the temperature falls below the set value, charging stops until the temperature rises above the recovery value. For extremely cold areas, the heating function is recommended.
Short Circuit Protection
Standard short circuit protection is included. Users can set short circuit delay (us) and recovery time (S) in the APP. If a short circuit occurs during charging (e.g., due to high peak current from the charger), increasing the delay time can resolve it. Similarly, for discharge short circuits (e.g., due to large capacitance loads), increasing the delay time can prevent false triggers.
Discharge Precharge Function (Optional)
An optional discharge precharge function is available, with a default precharge time of 5 seconds. Users can enable or disable this function as needed.
Emergency Switch
The standard emergency switch function allows the BMS to force charge and discharge for 30 minutes if issues like over-temperature, over-discharge, or cell imbalance occur. This provides an emergency operating window, even if a cell reaches its automatic shutdown voltage, to prevent critical failures.
Intelligent Sleep
The intelligent sleep function (standard) allows the BMS to enter a low-power state when the charge/discharge current is less than 1A for 26 consecutive hours. This reduces self-consumption. The BMS can be reactivated by pressing a button or connecting a charger.
Communication Function
The BMS supports optional CAN/RS485 communication. Users can configure the address and communication protocol via the APP according to their requirements. Refer to the JIKONG Protection Board communication protocol document for details.
6. User Tips
- Cables Included: The product package typically includes essential cables such as balance wires and an NTC temperature sensor, as confirmed by user inquiries.
- Temperature Monitoring: The BMS actively monitors temperature via the included NTC sensor, providing crucial protection against over-temperature and low-temperature conditions during charging and discharging.
- APP for Configuration: Utilize the JIKONG mobile APP (available for Android 7+ and iOS) to customize parameters like balance trigger voltage, protection thresholds, and to monitor real-time battery data.
- Wiring Accuracy: Always double-check the wiring, especially balance cables and main power connections (P- and B-), before activating the BMS to prevent damage.
7. Troubleshooting
General Troubleshooting Steps
- No Power/Activation Issue: Ensure the charger is connected and its voltage is at least 2V higher than the battery pack voltage for initial activation. Verify all wiring, especially P- and B- connections.
- Balancing Not Active: Check the active equalization settings in the APP. Ensure the balance trigger differential pressure is set appropriately and that the function is enabled.
- Protection Triggered Frequently: Review the overcurrent, overvoltage, undervoltage, and overtemperature settings in the APP. Adjust delay and recovery times if necessary, especially for short circuit protection with high-capacitance loads.
- Communication Issues: Ensure Bluetooth is enabled on your mobile device and the BMS. For RS485/CAN, verify wiring and communication protocol settings in the APP.
- Heating Function Not Working: If using the optional heating function, ensure it's enabled in the APP and that any external temperature control switches are functioning correctly.
8. Maintenance
- Regular Inspection: Periodically inspect all wiring connections for looseness or damage.
- Software Updates: Keep the JIKONG APP updated to the latest version for optimal performance and new features.
- Cleanliness: Keep the BMS board clean and free from dust and moisture to ensure proper heat dissipation and operation.
- Environmental Conditions: Operate the BMS within the specified temperature range (-30°C to 70°C) to prevent damage and ensure longevity.
9. Warranty and Support
9.1. Service Commitment
The product comes with a 3-year warranty from the date of receipt. The warranty covers quality issues not caused by human factors (e.g., functional failures, component defects). Service includes free repair or replacement based on product repairability evaluation.
9.2. After-Sales Process
(1) Customer Application
Submit applications through official after-sales channels (email/online customer service), providing order numbers, fault descriptions, and evidence (photos/videos).
(2) Return of Goods
The customer is responsible for international logistics costs for sending the product back to China and providing a tracking number.
(3) Packaging Requirements
Ensure product accessories are complete and packaging is intact to prevent damage during transit.
(4) Detection and Processing
After receiving, the quality department will complete inspection and repair/replacement within 5-7 working days. Responsibility definition: Non-human damage qualifies for free repair/replacement, with the seller bearing return logistics costs.
(5) Return and Tracking
After passing inspection, the repair/replacement product will be sent back with full logistics tracking information. Time commitment: Return logistics cycle is typically 7-15 working days (may vary due to customs clearance). Cross-border compliance: Customers need to cooperate in providing necessary customs declaration documents.
10. Frequently Asked Questions (FAQ)
Q: Does the BMS come with cables?
A: Yes, the package includes balance wires, an NTC temperature sensor, and a switch, along with the BMS unit and M6 screws.
Q: Does the BMS monitor temperature?
A: Yes, the JIKONG Smart BMS includes an NTC temperature sensor and features charge over temperature protection, discharge over temperature protection, and charge low temperature protection.
Q: What battery types are supported?
A: The BMS supports Li-ion, LiFePO4, and LTO battery types.
Q: How do I activate the BMS?
A: The BMS is activated by connecting a charger with a voltage at least 2V higher than the battery pack voltage. Optional models may also support button or display activation.