1. Product Overview
The JIKONG BD4A24S4P is an intelligent protection board designed for large-capacity series lithium battery packs. It integrates voltage acquisition, high-current active balancing, overcharge, over-temperature protection, coulomb meter, Bluetooth communication, and optional GPS remote functions. This BMS is suitable for LiFePO4, ternary lithium, and LTO battery types.
The protection board utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a continuous 0.4A balance current. This high-current active equalization technology ensures battery consistency, improves battery range, and extends battery life.
The BMS features a mobile APP compatible with Android and iOS systems, allowing users to monitor battery status, modify working parameters, and control charge/discharge switches via Bluetooth. Its compact size, ease of operation, and comprehensive functions make it ideal for battery packs in small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.


2. Functional Characteristics
The JIKONG BD4A24S4P BMS offers a wide range of functional characteristics:

- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 (Optional)
- Support CAN (Optional)
- Support parallel function (Optional)
- Support alarm function (Optional)
- Support heating function (Optional)
- Support GPS communication (Optional)
- Discharge precharge function (Optional)
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
3. Specifications
3.1. Basic Parameters
| Parameter | Value | Unit |
|---|---|---|
| Supply voltage | 20-100 | V |
| Operating power consumption | <800 | mW |
| Operating temperature | -30-70 | °C |
| Maximum number of collection strings | 24 | String |
| Maximum balancing current | 0.4 | A |
| Maximum charging current | 40 | A |
| Maximum discharge current | 40 | A |
| Maximum instantaneous current | 80 | A |
| Maximum internal loop resistance | 2.8 | mΩ |
| Protective plate size | 116*103*17.6 | mm |
| Finished weight | 205 | g |

3.2. Dimensions

4. Installation and Interface Definition
4.1. Product Appearance and Interfaces
The JIKONG BD4A24S4P BMS features multiple interfaces for communication and control. These include CAN, RS485, Bluetooth (BT), NTC, Soft Switch, SOC Indicator, Key Switch, and Active Equalizer. The physical interfaces are located on the side of the board.


4.2. Connector Pin Definitions
The BMS utilizes HY2.0-15P (P1) and HY2.0-11P (P2) connectors for balance and acquisition interfaces, along with HY2.0-4P (P3, P4) for temperature, 1.25T-4PWT (P5) for GPS, A1254WF-2A (P6) for buzzer, A1254WF-4A (P7) for communication, A1254WF-6A (P8) for display, and A1254WF-3A (P9) for parallel interface. A detailed pin definition table is available in the user manual PDF, section 5.2.
4.3. Wiring Diagram
The JK-BD4A24S-4P series protection board is suitable for 7-24 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. A detailed wiring diagram for a 24S configuration is provided in the user manual PDF, section 5.4. It illustrates connections for the load, charger, heating wire, temperature probe, and balance wires to the B- and B+ terminals.
5. Operating Instructions
5.1. APP Installation
To install the mobile APP, scan the QR code provided in the user manual PDF, section 6.1. An Android version 7 or higher is required for the APP to function correctly.

5.2. Device Activation
Before powering on the protection board, ensure that the balance cables are correctly connected and that the P- and B- terminals are properly wired. Verify that the protection board is securely fixed to the battery cells. Once confirmed, the protection board can be powered on.
The protection board does not have a physical power-on switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the BMS. Alternatively, the board can be activated via a key switch or display screen if these optional features are installed.
5.3. Parameter Setting
Detailed instructions for setting parameters can be found in the user manual PDF, section 6.3, titled "Instructions for Setting Protection Board Parameters."
5.4. Functional Descriptions
Active Equalization
The BMS uses active equalization to transfer energy from higher-voltage cells to lower-voltage cells. Before using this function, set basic battery parameters in the APP, including the number of cells, battery capacity, trigger equalization differential pressure (default is 0.01V), voltage calibration, and current calibration. The default balance current is 0.4A. Users can adjust this current based on battery capacity, ensuring it does not exceed 0.2C of the battery capacity. The equalization function can be turned off in the APP if not needed.

Heating Function (Optional)
The BMS supports an optional heating function to warm the battery at low temperatures using a resistance heater or heating film. This prevents charging and discharging failures due to reduced battery activity. The designed heating current is 10A. Users can switch this function on/off via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in series with the heating circuit as a secondary protection.Alarm Function (Optional)
The BMS supports an optional alarm function to provide external alerts when safety risks such as overtemperature, overcharge, or overdischarge are detected.
Battery Parallel Function (Optional)
This function allows the BMS to be used with parallel battery packs for energy storage applications. It requires synchronous use with a parallel module and disabling the "disable charging current limiting" function in the APP.
Charge Overvoltage Protection and Recovery
The BMS includes standard charge overvoltage protection. Users can set the single overcharge protection voltage and recovery voltage in the APP. If any cell's voltage exceeds the set protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages fall below the recovery voltage.
Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is included. Users can set the battery undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell's voltage drops below the protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell's voltage drops below the automatic shutdown voltage, the BMS will automatically shut down.
Charge Overcurrent Protection and Recovery
Standard charge overcurrent protection is provided. Users can set the continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set value for the specified delay, the BMS will stop charging. Charging resumes after the recovery time.
Discharge Overcurrent Protection and Recovery
Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set value for the specified delay, the BMS will stop discharging. Discharge resumes after the recovery time. Note: The maximum continuous discharge current should not exceed 40A.
Overtemperature Protection and Recovery
The BMS features standard charge and discharge overtemperature protection. Users can set the charge/discharge overtemperature protection and recovery temperatures in the APP. If the temperature exceeds the set value, the BMS will stop the respective operation. Operation resumes when the temperature falls below the recovery value.
Low Temperature Protection and Recovery (Charge)
Standard low temperature protection for charging is included. Users can set the charge low temperature protection and recovery temperatures in the APP. If the temperature drops below the set value, the BMS will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the optional heating function is recommended.
Short Circuit Protection and Recovery
The BMS is equipped with standard short circuit protection. Users can set the short circuit protection delay and recovery time in the APP. If a short circuit occurs, the BMS will stop the operation. After the recovery time, the BMS will resume operation. If a short circuit is triggered upon initial connection of a charger or load, increasing the delay time may resolve the issue.
Discharge Precharge Function (Optional)
The BMS supports an optional discharge precharge function. The default precharge time is 5 seconds. Users can enable or disable this function as needed. Setting the precharge time to 0 disables the function.
Emergency Switch
The BMS includes a standard emergency switch function. If issues like overtemperature, overdischarge, overcharge, or cell drop occur during normal use, activating the emergency switch in the APP will force the BMS to enable charge and discharge for 30 minutes, providing emergency operational time. The BMS will continue to operate until the 30-minute period ends, even if a cell voltage reaches the automatic shutdown voltage.
Intelligent Sleep
The BMS features intelligent sleep functionality. Users can enable or disable this in the APP. Its purpose is to reduce BMS power consumption when the board is in standby (charging/discharging current less than 1A for 26 consecutive hours). To reactivate, press a button or connect a charger.
Communication Function (Optional)
The BMS supports optional CAN and RS485 communication. Users can select these based on their requirements and set the address and communication protocol. Refer to the JIKONG Protection Board communication protocol document for specific details.
6. Packing List
The standard package includes the following items:

- BMS * 1
- NTC (400mm) * 1
- Balance Wires (750mm) * 1
- Switch (500mm) * 1
- Packing box * 1
7. Service Commitment and Warranty
The warranty covers the product for three years from the date of receipt, providing global warranty services for quality issues not caused by human factors (including functional failures, component defects, etc.).
For service, free repair or replacement is offered, depending on the product's repairability evaluation results.
After-Sales Process
- Customer Application: Customers submit applications through official after-sales channels (email/online customer service), providing order numbers, fault descriptions, and evidence (photos/videos).
- Return of Goods: The customer is responsible for the international logistics cost of sending the product back to China and must provide the waybill number for tracking purposes.
- Packaging Requirements: Ensure that product accessories are complete and the packaging is intact to avoid transportation damage.
- Detection and Processing: After receiving the product, the quality department will complete the inspection and inform the repair/replacement plan within 5-7 working days. Responsibility definition: Non-human damage will receive free repair/replacement, with the seller bearing the return international logistics costs.