1. Introduction
The eletechsup R4ROM01 is a mini single-channel RS485 relay board designed for various control applications. Its compact size and low-noise relay make it ideal for integration into existing equipment and systems. This manual provides detailed instructions for the proper installation, operation, and maintenance of your R4ROM01 relay board.
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to do so may result in electric shock, fire, or damage to the product.
- Ensure the power supply voltage matches the specified working voltage of the relay board (DC 5V, 12V, or 24V).
- Do not exceed the maximum load ratings: 3A/250VAC for resistive loads or 3A/30VDC for resistive loads. For inductive loads, ensure the current is within 1A.
- All wiring should be performed by qualified personnel and in accordance with local electrical codes.
- Avoid touching live terminals when the device is powered.
- Keep the device away from moisture, extreme temperatures, and corrosive environments.
3. Product Overview
The R4ROM01 is a compact RS485 relay board featuring a single SPDT (Single Pole Double Throw) relay. It supports MODBUS RTU protocol for remote control.
3.1. Key Features
- Mini Size: 40mm x 16mm x 14mm
- Ultra-light Weight: 9g
- Low Noise Relay
- MODBUS RTU Protocol Support
- Multiple Voltage Versions: DC 5V, 12V, 24V
3.2. Component Identification

As shown in Figure 1, the board includes:
- RS485 Bus Interface (B-, A+): For MODBUS RTU communication.
- Power Input Interface (GND, VIN): Connect your DC 5V, 12V, or 24V power supply here.
- Relay Output Interface (NC, COM, NO): Normally Closed, Common, Normally Open contacts for load control.
- Relay Indicator Light: Indicates the status of the relay.
- Working Indicator Light: Flashes when a correct command is received.
- RES Solder Points: Short these two points for 5 seconds to restore factory settings.
4. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | DC 5V / 12V / 24V (Three versions) |
| Standby Current (Relay Closed) | 5.5mA |
| Relay Open Current | 25mA |
| Control Commands | Open, Close, Momentary, Self-locking, Interlock, Delay (6 commands) |
| MODBUS RTU Commands | Write 05/06/15/16, Read 01/03 |
| Maximum Delay (Delay Command) | 255 seconds |
| Parallel Devices (MODBUS) | Up to 64 devices |
| Baud Rate | 1200/2400/4800/9600 (Default)/19200/38400/57600/115200BPS |
| Parity | None (Default)/Even/Odd |
| Dimensions | 40mm x 16mm x 14mm |
| Weight | 9g |
| Maximum Load (Resistive) | 3A/250VAC, 3A/30VDC |
| Maximum Load (Inductive) | 1A |
| Contact Arrangement | SPDT |
| Power Source | DC |
| Theory | Time Relay |
| Contact Load | Low Power |
| Protection Feature | Sealed |
| Terminal Specification | 3.96MM pitch, 2.5MM slotted screw |
5. Setup and Installation
Follow these steps to correctly install and wire your R4ROM01 relay board.
5.1. Wiring Diagram

5.2. Connection Steps
- Power Input: Connect your DC power supply (5V, 12V, or 24V, depending on your board version) to the VIN (positive) and GND (negative) terminals.
- RS485 Communication: Connect your RS485 bus to the A+ and B- terminals. Ensure correct polarity.
- Load Connection: Connect your load to the relay output terminals:
- COM: Common terminal.
- NO: Normally Open (relay closes when activated).
- NC: Normally Closed (relay opens when activated).
The load power can be DC 1-110V or AC 85-265V, within the specified current limits (3A resistive, 1A inductive).
5.3. MODBUS Control Scenarios

- Single Board Control: Use a USB to RS485 converter to control a single R4ROM01 board for parameter settings (e.g., RS485 address).
- Multiple Board Control: When controlling multiple boards via a USB to RS485 converter, each board must be assigned a unique RS485 address.
- PLC Integration: The RS485 interface of a PLC can be used to expand external output ports. Each R4ROM01 board connected to the PLC must have a different RS485 address.
6. Operating Instructions
The R4ROM01 relay board is controlled using MODBUS RTU commands. These commands can be sent via a serial HyperTerminal (serial assistant) or a dedicated Modbus Poll software.
6.1. Basic Commands
The relay board supports 6 basic control commands:
- Open: Activates the relay (closes NO, opens NC).
- Close: Deactivates the relay (opens NO, closes NC).
- Momentary: Activates the relay for a brief period and then deactivates it.
- Self-locking: Toggles the relay state with each command.
- Interlock: Used in multi-relay systems to ensure only one relay is active at a time.
- Delay: Activates the relay for a specified duration (up to 255 seconds).
6.2. MODBUS RTU Command Mode
In MODBUS command mode, the device can support up to 64 devices in parallel, each requiring a unique RS485 address. The default baud rate is 9600BPS with no parity.
6.3. Restoring Factory Settings
To restore the board to its factory default settings, short the two RES solder points (refer to Figure 1) for 5 seconds.
7. MODBUS RTU Commands
For detailed information on MODBUS RTU commands, including specific function codes (Write 05/06/15/16, Read 01/03) and their parameters, please refer to the dedicated 'R4ROM01 MODBUS RTU Command' protocol manual. This manual provides comprehensive guidance on implementing and utilizing the MODBUS RTU protocol with the R4ROM01 board.
8. Applications
The R4ROM01 relay board is suitable for a wide range of applications, including but not limited to:
- PC Computer remote control
- Small size electronic switch
- PLC Output expansion board
- Smart Home, Home Automation
- PTZ CCTV IP Camera control
- Security Monitoring systems
- Identification systems
- Mini Motor Control
- Automatic curtain control
- LED Control
9. Troubleshooting
If you encounter issues with your R4ROM01 relay board, consider the following troubleshooting steps:
- No Power/Indicator Lights Off: Check your DC power supply connections (VIN, GND) and ensure the voltage matches the board's requirement.
- No Response to Commands:
- Verify RS485 wiring (A+, B- polarity).
- Check communication parameters (baud rate, parity) match between your controller and the relay board. Default is 9600BPS, None parity.
- Ensure the RS485 address of the board is correctly set and matches the command.
- Confirm the working indicator light flashes when a command is sent, indicating command reception.
- Relay Not Activating Load:
- Check load wiring (NC, COM, NO).
- Ensure the load's voltage and current are within the relay's maximum ratings (3A resistive, 1A inductive).
- Verify the relay indicator light changes state when a command is sent.
- Intermittent Operation: Check for loose connections, power supply fluctuations, or electromagnetic interference.
10. User Tips
- For detailed programming and command structures, always refer to the official 'R4ROM01 MODBUS RTU Command' protocol manual. This document contains all necessary information for advanced usage and integration.
- When using multiple R4ROM01 boards on the same RS485 bus, ensure each board has a unique MODBUS address to prevent communication conflicts.
- Consider using shielded twisted-pair cables for RS485 communication in noisy environments to improve signal integrity.
11. Maintenance
The R4ROM01 relay board is designed for low maintenance. To ensure optimal performance and longevity:
- Keep the board clean and free from dust and debris. Use a soft, dry cloth for cleaning.
- Avoid exposing the board to excessive moisture or extreme temperatures.
- Periodically check all wiring connections to ensure they are secure.
- Do not attempt to repair the board yourself if it is damaged. Contact the seller for assistance.
12. Warranty and Support
For any questions, technical support, or warranty inquiries regarding your eletechsup R4ROM01 Mini RS485 Relay Board, please contact the seller directly through the platform where you purchased the product. Provide your order details and a clear description of the issue for prompt assistance.