1. Product Overview
The JIKONG JKBMS V19 Inverter BMS is an intelligent protection board designed for large-capacity series lithium battery packs. It features voltage acquisition, high-current active balancing, overcharge/over-discharge/overcurrent/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring functions. It is suitable for LiFePO4, Li-ion, and LTO battery types.
The BMS utilizes energy transfer active balancing technology, capable of achieving a maximum continuous balance current of 1A or 2A (depending on the model). This technology ensures battery consistency, extends battery life, and delays aging.
The system supports mobile APP (Android and iOS) for monitoring battery status, modifying parameters, and controlling charge/discharge switches. It also features a 4.3-inch LCD touch screen display for convenient real-time information viewing.

2. Safety Protection Measures and Precautions
WARNING: Please read this manual carefully before use to prevent damage or injury.
- Always connect cables from the negative terminal to the positive terminal according to the wiring diagram.
- After connecting the balanced wire, use a multimeter to confirm correct wiring before inserting the protection board.
- The default password for the protection board is 1234.
- The default authorization password is 123456.
- After connecting the mobile phone APP to the protection board, change the connection password immediately to prevent unauthorized access.
- Do not modify the power lines of the protection board without permission. Unauthorized modifications can lead to uneven overcurrent and burn out the protection board.
3. Setup and Installation
3.1. Packing List
Ensure all components are present before proceeding with installation.

3.2. Wiring Method for 16-String Cells
Follow the diagram carefully for connecting 16-string cells. Ensure all connections are secure and correct.

3.3. Interface Board Connections
The interface board provides various ports for communication and control.

3.4. Device Activation
Before powering on the protection board, reconfirm that the balance cables are properly connected and that P- and B- are correctly wired. Ensure the protection board is securely fixed to the battery cells.
The protection board does not have a power-on control switch. It is designed for charging activation mode (charger voltage 2V higher than battery voltage). After battery assembly, connect the charger to activate the protection board.
Alternatively, the protection board supports key activation and display activation. If using the display screen and button, simply insert the cable into the display interface and press the button to activate.
4. Operation
4.1. Mobile APP and PC Software
The JIKONG BMS can be monitored and configured via a mobile APP (Android/iOS) or PC software. The APP allows for protocol selection, basic settings, and real-time data viewing.

To download the mobile APP, scan the QR code below:
4.2. 4.3-inch Touch Screen Display
The 4.3-inch LCD touch screen provides a clear interface for monitoring battery information directly.


4.3. Parallel Function
The parallel function allows multiple BMS units to be monitored simultaneously by a host computer via RS485 bus. This requires a USB to RS485 serial port cable and the JIKONG upper computer software.
The system supports up to 16 BMS units in parallel (addresses 0-15). BMS with address 0 acts as the host, and addresses 1-15 are slaves. Addresses are set using DIP switches on the interface board.

5. Maintenance
5.1. Active Equalization for Battery Longevity
The active equalization technology employed by the JIKONG BMS helps maintain battery consistency, which is crucial for prolonging the overall lifespan and performance of your battery pack. By transferring energy from high-voltage cells to low-voltage cells, it prevents imbalances that can lead to premature aging and reduced capacity.
5.2. Intelligent Sleep Function
The BMS includes an intelligent sleep function to reduce its own power consumption when the battery pack is in standby (charging/discharging current less than 1A for 26 consecutive hours). This feature helps conserve battery energy. The BMS can be reactivated by pressing a button or connecting a charger.
5.3. Heating Function
The BMS is equipped with a heating function to warm the battery in low-temperature conditions, preventing reduced battery activity and performance issues. The heating current is 10A. For extreme cold, it is recommended to use this function with appropriate heating elements and a temperature control switch (45-65°C normally closed type) as a secondary protection.
6. Troubleshooting
6.1. Protection Functions and Recovery
The BMS is equipped with various protection mechanisms to safeguard your battery system:
- Overcharge Protection: Shuts off charging if any cell voltage exceeds the set limit. Recovers when all cell voltages drop below the recovery threshold.
- Over-discharge Protection: Shuts off discharge if any cell voltage drops below the set limit. Recovers when the battery is charged and all cell voltages rise above the recovery threshold.
- Overcurrent Protection (Charge/Discharge): Triggers if current exceeds the set continuous limit for a specified delay. Recovers after a set release time.
- Over-temperature Protection (Charge/Discharge): Triggers if temperature exceeds the set limit. Recovers when temperature drops below the recovery threshold.
- Low-temperature Protection (Charge): Triggers if temperature drops below the set limit. Recovers when temperature rises above the recovery threshold.
- Short Circuit Protection: Triggers upon detecting a short circuit. Recovery time can be adjusted via APP. If a short circuit occurs when connecting a charger or load, increasing the delay time may resolve it if the issue is due to peak instantaneous current.
6.2. Emergency Switch
In case of issues like over-temperature, over-discharge, over-charge, or dropped strings, activating the emergency switch via the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides an emergency operational window, even if a single cell reaches the automatic shutdown voltage.
6.3. LED Indicators
The interface board features LED indicators to help diagnose the BMS status:
| Status | ON/OFF Indicator | RUN | ALM | L1-L6 (Power LEDs) | Description |
|---|---|---|---|---|---|
| Power Off | OFF | OFF | Device is off. | ||
| Balance (Normal) | ON | Flicker | OFF | Battery based display | Indicates balancing activity. |
| Charging (Normal) | ON | Flicker | OFF | Battery based display | Indicates normal charging. |
| Charging (Overcurrent, Overtemp, Overvoltage, Failure) | ON | Flicker | Flicker | Battery based display | Indicates a charging protection event. |
| Discharging (Normal) | ON | Flicker | OFF | Battery based display | Indicates normal discharging. |
| Discharging (Overcurrent, Overtemp, Undervoltage, Failure) | ON | Flicker | Flicker | Battery based display | Indicates a discharging protection event. |
| Other Alarms (Password not changed, Short circuit, Temperature) | ON | Flicker | Flicker | Battery based display | Indicates other system warnings. |
7. Specifications
7.1. General Product Specifications
| Technical Index | Description |
|---|---|
| Brand Name | JIKONG |
| Type | LIFEPO4 Battery BMS |
| Usage Scenario | Energy Storage BMS |
| Balance Function | Active Balanced BMS |
| Handware or Smart | SMART BMS |
| Charge and Discharge Port | Common Port BMS |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
| Battery Type | Li-ion / lifepo4 / LTO |
| Supported interfaces | RS485/CAN/UART |
| Adapting system | Android or iOS Harmony |
| Battery Strings | 16S |
| Parallel function | Support |
| Certification | CE |
7.2. Model-Specific Specifications

7.3. Dimensions and Weight
| Parameter | Value |
|---|---|
| Protective Plate Size | 300mm × 100mm × 24mm |
| Finished Weight | 1000g |
| Package Length | 35cm |
| Package Width | 20cm |
| Package Height | 15cm |
| Package Weight | 1.4kg |

8. User Tips
- Password Management: Remember to change the default Bluetooth (1234) and parameter setting (123456) passwords immediately after initial setup to enhance security.
- Wiring Verification: Always double-check all wiring, especially balance cables and main power lines, with a multimeter before applying power to prevent damage.
- Parallel Setup: When using multiple BMS units in parallel, ensure each unit has a unique address set via the DIP switches (0 for host, 1-15 for slaves).
- Troubleshooting Alarms: Refer to the LED indicator table in the Troubleshooting section to quickly identify the nature of any alarm or protection event.
9. Warranty and Support
This product is manufactured by Chengdu Jikong Technology Co., LTD. For technical support or inquiries, please contact the manufacturer directly.
JIKONG is a highly-rated brand known for its quality and low return rates. The company has a strong development team and offers rapid technical support to meet various customization needs.