1. Introduction
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Megarevo Three-Phase High Voltage Hybrid Inverter. This inverter is designed for residential energy storage systems, supporting both on-grid and off-grid applications, and can be paralleled for increased capacity. Please read this manual thoroughly before installation and operation.
2. Key Features
- Three-phase high voltage hybrid inverter for residential use.
- Supports up to 6 parallel machines for scalable power solutions.
- Mainstream battery automatic matching for seamless integration.
- Full power discharge capability with automatic battery charge and discharge management.
- Compatible with both single-phase and three-phase loads, supporting 100% unbalanced loads.
- High efficiency (Max. 99.5%) and MPPT efficiency (99.9%).
- Robust design with IP65/Type 3R ingress protection.
- Natural cooling system.
- LCD touch screen display for easy monitoring and control.
- Communication interfaces: RS485, WiFi, 4G/CAN/DRM.

3. Technical Specifications
| Feature | R8KH3 | R10KH3 | R12KH3 |
|---|---|---|---|
| Input (PV) | |||
| Max. power (kW) | 12 | 15 | 18 |
| Max. DC voltage (V) | 1000 | ||
| MPPT voltage range (V) | 180-850 | ||
| AC Output | |||
| Rated output power (kVA) | 8 | 10 | 12 |
| Max. output current (A) | 12.7 | 15.9 | 19.1 |
| Grid voltage/range (V) | 400/360-440 | ||
| Frequency (Hz) | 50/60 | ||
| AC output topology | 3W+N+PE | ||
| Battery | |||
| Battery voltage range (V) | 125-600 | ||
| Max. charging voltage (V) | 600 | ||
| Full battery voltage (V) | 250 | 300 | 350 |
| Rated charge/discharge current (A) | 40 | ||
| Battery type | Lithium / Lead-acid | ||
| Communication interface | CAN/RS485 | ||
| General Data | |||
| Max. efficiency | 99.5% | ||
| Ingress protection | IP65/Type 3R | ||
| Operation temperature | -25°C ~ 60°C | ||
| Dimensions W*D*H (mm) | 530*200*600 | ||
| Weight (kg) | 29 | ||
| Display | LCD, touch screen | ||
| Interface: RS485/Wifi/4G/CAN/DRM | Yes/Opt/Opt/Yes/Yes | ||
| Safety standard | IEC/EN62109-1/-2, IEC/EN62477-1 | ||

4. Installation and Wiring
The Megarevo Hybrid Inverter is designed for integration into a comprehensive energy system including solar PV, battery storage, and connection to the utility grid and local loads. Proper installation is crucial for safety and optimal performance. It is recommended that installation be performed by a qualified electrician.
4.1 System Overview

4.2 Physical Installation
- Ensure the installation location is well-ventilated, protected from direct sunlight, rain, and excessive dust.
- Mount the inverter securely on a vertical surface using appropriate fasteners. Refer to the dimensions (530*200*600 mm) and weight (29 kg) for proper mounting considerations.
- Maintain adequate clearance around the inverter for natural cooling.
4.3 Electrical Connections
Connect the following components to the inverter as per the system diagram (Figure 4.1) and local electrical codes:
- **PV Input**: Connect the solar panel strings to the designated PV+ and PV- terminals. Ensure correct polarity and voltage within the MPPT range (180-850V) and max DC voltage (1000V).
- **Battery Connection**: Connect the battery bank (Lithium or Lead-acid, 125-600V range) to the battery terminals. Ensure proper communication via CAN/RS485 for battery management.
- **AC Grid Connection**: Connect the inverter to the three-phase utility grid (380V/400V, 50/60Hz) at the designated AC output terminals.
- **Load Connections**: Connect your household loads, distinguishing between 'Important Load' (critical loads that need continuous power) and 'Normal Load'.
- **Communication**: Connect necessary communication cables (RS485, WiFi, 4G/CAN/DRM) for monitoring and control via the Cloud Platform.


5. Operation Modes
The Megarevo Hybrid Inverter supports various operating modes to optimize energy usage and ensure continuous power supply. The LCD touch screen allows for easy configuration and monitoring of these modes.
5.1 Working Mode 1: On-Grid Applications
In this mode, the inverter prioritizes feeding excess solar power back to the grid while also charging the battery. When solar production is insufficient, loads are powered by the grid and/or battery. The inverter ensures a seamless transition between on-grid and off-grid operation in case of grid failure, with a switch time of less than or equal to 10ms.
5.2 Working Mode 2: Off-Grid Applications (Self-Consumption)
This mode focuses on maximizing self-consumption of solar energy. Solar power directly supplies the loads and charges the battery. Only when solar and battery power are insufficient will the grid be utilized. This mode is ideal for reducing reliance on the utility grid and optimizing energy independence.
The video above also illustrates the off-grid application, demonstrating how the system operates independently from the grid, drawing power from PV and battery to supply local loads.
5.3 Parallel Operation
The Megarevo inverter supports parallel operation of up to 6 units to increase the overall system capacity. This feature allows for flexible system expansion based on energy demands.

6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your Megarevo Hybrid Inverter. Always disconnect power before performing any maintenance.
- **Visual Inspection**: Periodically check the inverter for any visible damage, loose connections, or signs of overheating.
- **Cleaning**: Keep the inverter's exterior clean and free from dust and debris. Use a soft, dry cloth. Do not use liquids or abrasive cleaners.
- **Ventilation**: Ensure that the cooling fins and ventilation openings are not blocked to allow for proper natural cooling.
- **Connection Checks**: Annually, inspect all electrical connections (PV, battery, AC grid, loads) for tightness and corrosion.
- **Firmware Updates**: Check for available firmware updates from Megarevo to ensure your inverter has the latest features and bug fixes.
7. Troubleshooting
This section provides basic troubleshooting steps for common issues. For complex problems, contact technical support.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not powering on | No DC input from PV or battery; AC input not connected; Emergency stop engaged. | Check PV and battery connections and voltage. Ensure AC breaker is on. Disengage emergency stop. |
| Low power output | Insufficient solar irradiation; Dirty PV panels; Battery low; Overload. | Check weather conditions. Clean PV panels. Check battery state of charge. Reduce load. |
| Error message on display | Internal fault; External connection issue; Parameter misconfiguration. | Note the error code and consult the full manual or contact support. Check all connections. Verify settings. |
| No grid connection | Grid outage; AC breaker tripped; Incorrect grid parameters. | Check utility grid status. Reset AC breaker. Verify grid settings on the inverter. |
8. User Tips
- **Monitor Regularly**: Utilize the LCD touch screen and the Cloud Platform to regularly monitor your system's performance, battery status, and energy flow.
- **Optimize Battery Usage**: Configure the battery charge/discharge cycles to align with your energy consumption patterns and local electricity tariffs to maximize savings.
- **Safety First**: Always prioritize safety. If you are unsure about any installation or maintenance step, consult a certified professional.
- **Keep Documentation**: Retain this manual and any other system documentation for future reference.
9. Warranty and Support
The Megarevo Hybrid Inverter comes with a 5-year warranty, ensuring peace of mind regarding product quality and performance.
9.1 Technical Support
For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Megarevo support:
- Email: 19311644844@163.com
- Whatsapp: +86 19311644844
- WeChat: +86 19311644844
When contacting support, please have your inverter model number and any relevant error codes ready.