SUMRY HGX 4KW

Contents

SUMRY HGX 4KW Hybrid Inverter User Manual

Model: HGX 4KW 24V 110/120V

1. Introduction

The SUMRY HGX 4KW Hybrid Inverter is a versatile off-grid solar inverter designed to provide reliable power for various applications. It features a pure sine wave output, a built-in MPPT solar charge controller, and a user-friendly 6.25-inch LCD touch screen display. This inverter supports multiple battery types and offers comprehensive protection systems to ensure safe and efficient operation.

Key Features:

  • Power Output: 4000W (4KW)
  • Battery Voltage: 24VDC
  • Input/Output Voltage: 110/120VAC (selectable range 90-140VAC)
  • Waveform: Pure Sine Wave
  • Max. AC Charge Current: 110A
  • Max. PV Array Power: 5600W
  • MPPT Voltage Range: 55-280VDC
  • Max. PV Array Open Circuit Voltage: 350VDC
  • Frequency Range: 50/60Hz
  • Display: 6.25-inch LCD Touch Screen
  • Operating Modes: SBU mode (utility, battery, and PV power complement each other), No battery function available
  • Smart Features: Smart battery charger design, Configurable AC/Battery input priority via LCD setting, Optional WiFi monitoring
  • Safety: Cold restart function, Intelligent Protection Systems (Overload, Overheating, High/Low Voltage, Battery, Short Circuit, Overcurrent, Anti-Reverse, Power Failure Protection)
SUMRY HGX 4KW Hybrid Inverter with key specifications

Figure 1: SUMRY HGX 4KW Hybrid Inverter highlighting key specifications.

Key features of the SUMRY HGX 4KW Solar Inverter

Figure 2: Overview of the SUMRY HGX 4KW Solar Inverter's main features.

2. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your inverter. All wiring must be performed by qualified personnel.

2.1 Unboxing and Inspection

Upon receiving your inverter, carefully unbox it and inspect for any signs of damage. Ensure all components are present.

Video 1: Unboxing and initial wiring demonstration of the SUMRY Hybrid Inverter.

2.2 Physical Overview and Connections

Familiarize yourself with the inverter's connection ports:

Side view of SUMRY Hybrid Inverter with labeled connection ports

Figure 3: Labeled connection ports on the SUMRY Hybrid Inverter.

  • PV Input: Connects to your solar panels.
  • AC Input: Connects to the utility grid or a generator.
  • AC Output: Connects to your household appliances/load.
  • Battery Input: Connects to your battery bank.
  • RS458/RS232 Communication Port: For data communication and optional WiFi module.
  • Input Breaker: For AC input protection.
  • Ground Terminal: For safety grounding.

2.3 PV Connection Guidelines

When connecting PV modules, ensure you install a DC circuit breaker separately between the inverter and PV modules. Use appropriate cables to reduce the risk of injury and ensure system safety and efficient operation.

Solar panel wiring diagram for series and parallel configurations

Figure 4: Solar photovoltaic panel wiring methods (Series/Parallel).

PV Module Selection Parameters:

  1. Open circuit Voltage (Voc) of PV modules should not exceed the maximum PV array open circuit voltage of the inverter (350Vdc).
  2. PV Array MPPT Voltage Range should be within 55Vdc to 280Vdc.
PV Connection table with wire size and torque values

Figure 5: Recommended wire sizes and torque values for PV connections.

Recommended PV cable dimensions: 6-8A/mm².

2.4 Battery Connection

The inverter is compatible with various battery types, including Lead-acid (Flooded, Gel, AGM/Sealed), Lithium-ion, and user-customizable settings.

Compatible battery types for the SUMRY Hybrid Inverter

Figure 6: Battery compatibility chart.

2.5 Optional WiFi Monitoring

The inverter supports optional WiFi monitoring via a dedicated module and a smart app. This allows for remote monitoring and control of your system.

Inverter connected to an optional WiFi monitoring module and smartphone app

Figure 7: WiFi monitoring setup with optional module and smartphone app.

3. Operating Instructions

The inverter features an intuitive LCD display and touch buttons for easy operation and monitoring.

3.1 LCD Display and Indicators

LCD display and touch buttons with indicator descriptions

Figure 8: LCD display, LED indicators, and function keys.

The LCD displays real-time system status, including input/output voltage, battery status, and charging information.

LED Indicators:

  • AC/INV (Green):
    • Solid On: Output is powered by utility in Line mode.
    • Flashing: Output is powered by battery or PV in battery mode.
  • CHG (Green):
    • Solid On: Battery is fully charged.
    • Flashing: Battery is charging.
  • FAULT (Red):
    • Solid On: Fault occurs in the inverter.
    • Flashing: Warning condition occurs in the inverter.

3.2 Function Keys

The touch buttons allow you to navigate through settings and monitor data:

  • ESC: To exit setting mode.
  • UP: To go to previous selection.
  • DOWN: To go to next selection.
  • ENTER: To confirm the selection in setting mode or enter setting mode.

3.3 Operating Modes

The inverter supports an SBU mode, where utility power, battery power, and PV power complement each other to provide continuous power. It also offers a 'no battery' function for direct solar to load operation.

3.4 Cold Restart Function

The cold restart function allows the inverter to start up directly from solar power without a battery, under suitable solar conditions.

4. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are unobstructed.
  • Connection Checks: Periodically check all electrical connections (PV, battery, AC input/output) to ensure they are secure and free from corrosion.
  • Environmental Conditions: Ensure the inverter is operating within its specified temperature and humidity ranges. Avoid direct sunlight and excessive moisture.
  • Firmware Updates: If using the optional WiFi module, check for available firmware updates to ensure optimal performance and access to new features.

5. Troubleshooting

This section provides guidance on common issues. For complex problems, contact qualified service personnel.

5.1 LED Indicator Faults

Refer to the 'FAULT' LED indicator messages (Section 3.1) for initial diagnosis. A solid red light indicates a fault, while a flashing red light indicates a warning condition.

5.2 Common Issues and Solutions

ProblemPossible CauseSolution
Inverter not turning onNo battery power, AC input not connected, or main switch off.Check battery connections and charge level. Verify AC input and ensure the ON/OFF switch is engaged.
No AC outputOverload, short circuit, or inverter fault.Reduce load. Check for short circuits in wiring. Consult fault codes on LCD.
Battery not chargingPV input too low, battery fault, or charging settings incorrect.Ensure sufficient solar irradiance. Check PV connections. Verify battery type and charging settings on the LCD.
Overload protection activatedConnected load exceeds inverter capacity.Disconnect non-essential loads. Ensure total load is within the inverter's 4000W continuous rating.

6. Specifications

FeatureSpecification
Model NumberHGX 4KW 110V
Output Current20A
Size400*250*89MM
Output TypeSINGLE
Weight12KG
Brand NameSUMRY
Output Frequency50/60Hz
Is Smart DeviceYes
OriginMainland China
CertificationCE, FCC, RoHS
Supported Battery TypesLead acid battery, lithium battery, Lifepo4 battery, and so on (Flooded, Gel, Lithium-ion phosphate, Lithium-ion, AGM/Sealed, User custom)
Input Voltage110/120V
Selectable Voltage Range90/140 VAC
Wave FormPure Sine Wave
Battery Voltage24V
MPPT Voltage Range55-280VDC
Max PV Array Power5600W
Max. PV Array Open Circuit Voltage350VDC
Max. Charging Current (AC charger + solar charger)140A

7. User Tips

  • System Sizing: Always ensure your solar panel array and battery bank are appropriately sized for your energy consumption and the inverter's capabilities to maximize efficiency and lifespan.
  • Battery Settings: Take advantage of the configurable battery settings on the LCD to match your specific battery type (e.g., Flooded, LiFePO4) for optimal charging and discharge cycles.
  • Ventilation: Ensure the inverter is installed in a well-ventilated area to prevent overheating, which can impact performance and longevity.
  • Professional Installation: For safety and to ensure correct operation, consider having the inverter installed by a qualified electrician or solar professional.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your retailer or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.