SUMRY HGX 4KW 110V

Contents

SUMRY HGX 4KW 110V Off Grid Hybrid Solar Inverter

Instruction Manual

1. Product Overview

The SUMRY HGX 4KW 110V is a versatile off-grid hybrid solar inverter designed to provide reliable power for various applications. It features a pure sine wave output, an integrated MPPT solar charge controller, and a user-friendly touch screen LCD display. This inverter is capable of operating with or without a battery, offering flexibility for different solar power system configurations.

Key Features:

  • 4KW 24VDC / 110/120VAC Pure Sine Wave Output
  • Built-in 140A MPPT Solar Charge Controller (Max PV 5600W)
  • 6.25-inch Touch Screen LCD Display
  • Tempered Glass Upper Cover
  • SBU Mode: Utility power, battery, and PV power complement each other
  • High PV Input Range: 55V-350Vdc
  • Smart Battery Charger Design for Optimized Battery Performance
  • Configurable AC/Battery Input Priority via LCD Setting
  • Cold Restart Function
  • Optional WiFi Monitoring via SmartESS App
  • Silent Fan Operation

Protection Systems:

The inverter incorporates intelligent protection systems for enhanced safety and longevity:

  • Overload Protection
  • Overheating Protection
  • High/Low Voltage Protection
  • Battery Protection
  • Short Circuit Protection
  • Overcurrent Protection
  • Anti-Reverse Protection
  • Power Failure Protection
SUMRY HGX Series Hybrid Inverter product shot
SUMRY HGX Series Hybrid Inverter
Diagram illustrating intelligent protection systems
Intelligent Protection Systems
Unboxing, connection, and demonstration of the inverter powering various appliances.

2. Setup and Installation

Safety Precautions:

  • All wiring must be performed by qualified personnel.
  • Ensure a DC circuit breaker is installed separately between the inverter and PV modules.
  • Use appropriate cable for PV module connection to ensure system safety and efficient operation.
  • Verify all connections are secure before powering on the unit.

Connection Ports:

Rear view of the inverter showing connection ports
Rear Panel Connections
  • PV Input: Connect solar panel arrays.
  • AC Input: Connect to utility grid or generator.
  • AC Output: Connect to household appliances or load center.
  • Battery Input: Connect to 24V battery bank (positive and negative terminals).
  • RS458/RS232 Communication Port: For data communication and optional WiFi module connection.

PV Connection Guidelines:

PV Connection guidelines including warnings, wire size table, and inverter model specifications for PV array
PV Connection Guidelines and Specifications

When selecting proper PV modules, consider the following parameters:

  1. Open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter (350Vdc).
  2. Open circuit Voltage (Voc) of PV modules should be higher than the minimum PV Array MPPT Voltage range (55Vdc).

Recommended Wire Size for PV Connection:

ModelWire SizeCable (mm²)Torque Value (max)
3.0KW/4.0KW1 x 12AWG41.2 Nm

Solar Panel Wiring Methods:

Solar photovoltaic panel wiring methods (series/parallel) with voltage and current calculations and cable dimensions
Solar Photovoltaic Panel Wiring (Series/Parallel)
  • In Series: Increases the voltage of the system. The total voltage needs to be less than the hybrid inverter's maximum input Voc. The entire photovoltaic system should use the same type of photovoltaic panel.
  • In Parallel: Increases the current of the system. The total current should not exceed the maximum PV input current of the hybrid inverter.
  • PV Cable Dimensions: Recommended 6-8A/mm².

3. Operation

LCD Display and Function Keys:

Detailed view of the inverter's LCD display, charging indicator, status indicator, fault indicator, and function touch buttons, along with a table of LED indicators and function key descriptions
LCD Display, Indicators, and Function Keys

The inverter features a 6.25-inch touch screen LCD display for monitoring and configuration. The display shows real-time status, charging, and fault indicators.

LED Indicators:

LED IndicatorColorMessages
AC/INVGreenSolid On: Output is powered by utility in Line mode.
Flashing: Output is powered by battery or PV in battery mode.
CHGGreenSolid On: Battery is fully charged.
Flashing: Battery is charging.
FAULTRedSolid On: Fault occurs in the inverter.
Flashing: Warning condition occurs in the inverter.

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

Operating Modes:

The inverter supports SBU mode, where utility power, battery, and PV power work together to supply the load. Input priority (AC/Battery) can be configured via the LCD settings.

Battery Compatibility:

Inverter compatible with multiple battery types
Compatible Battery Types

The inverter is compatible with various 24V battery types, including:

  • Flooded
  • Gel
  • Lithium-iron phosphate (LiFePO4)
  • Lithium-ion
  • AGM/Sealed
  • User custom Battery settings

Remote Monitoring (Optional):

Inverter monitoring and control via SmartESS App, showing a smartphone interface and an optional WiFi module
Monitor and Control via SmartESS App (WiFi Optional)

With the optional WiFi module, you can monitor and control your inverter remotely using the SmartESS App on your smartphone or tablet.

4. Maintenance

Regular maintenance ensures optimal performance and extends the lifespan of your SUMRY HGX inverter.

  • Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust buildup, which can hinder cooling. Use a soft, dry cloth.
  • Connections: Regularly check all electrical connections (PV, AC input/output, battery) for tightness and signs of corrosion. Loose connections can cause overheating and poor performance.
  • Ventilation: Ensure the inverter is installed in a well-ventilated area, free from obstructions, to allow for proper heat dissipation.
  • Environment: Keep the inverter away from direct sunlight, moisture, and corrosive substances.
  • Firmware Updates: Check the manufacturer's website periodically for any available firmware updates to ensure your inverter has the latest features and bug fixes.

5. Troubleshooting

This section provides guidance for common issues. For more complex problems, contact technical support.

LED Indicator Warnings:

  • FAULT (Red Solid On): Indicates a fault condition. Refer to the inverter's detailed error codes (if available in the full manual) or contact support.
  • FAULT (Red Flashing): Indicates a warning condition. This might be due to temporary issues like high temperature or low battery voltage. The inverter may recover automatically once conditions normalize.

Common Questions:

  • Does it work without a battery? Yes, the inverter can operate without a battery in certain modes, typically for direct PV to load or grid-tie applications. However, for energy storage and continuous power supply during outages or at night, a 24V battery bank is required.
  • How to configure grid modes (Off-Grid/On-Grid)? The inverter is a hybrid model, supporting both off-grid and on-grid functionalities. Specific settings for grid modes and power priority (e.g., SBU mode) are configured via the LCD display using the UP, DOWN, and ENTER buttons. Refer to the detailed settings menu in the comprehensive user manual for step-by-step instructions.

6. Specifications

FeatureSpecification
Brand NameSUMRY
Model NumberHGX 4KW 110V
Size400*250*89MM
Weight12KG
Output TypeSINGLE
Output Current20A
Output Frequency50/60Hz
Is Smart DeviceYes
OriginMainland China
CertificationCE, FCC, RoHS
Supported Battery TypesLead acid battery, lithium battery, Lifepo4 battery, etc.
Input Voltage110/120V
Selectable Voltage Range90/140 VAC
Wave FormPure Sine Wave
Battery Voltage24V
MPPT Voltage Range55-280VDC
Max PV Array Power5600W
Max PV Array Open Circuit Voltage350VDC
Max Charging Current140A (AC charger + solar charger)

7. Warranty and Support

The SUMRY HGX 4KW 110V Off Grid Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase.

For technical assistance, troubleshooting, or warranty claims, please contact your seller or the SUMRY official support channel. Ensure you have your purchase details and product serial number available.

8. User Tips

  • Quiet Operation: Users have noted the inverter operates with a silent fan, contributing to a quieter environment.
  • Battery Flexibility: While the inverter can function without a battery in certain direct PV-to-load scenarios, consider adding a compatible 24V battery bank for energy storage and uninterrupted power supply.
  • App Monitoring: Utilize the optional WiFi module and SmartESS App for convenient remote monitoring and control of your solar system.