1. Product Overview

The JKBMS P-Link-CR-V2.0 Communication Interface Board is designed to provide a communication expansion interface for the parallel function of JKBMS Smart Battery Management Systems (BMS). This board facilitates advanced communication and parallel operation of multiple BMS units.

Key Features:

  • Smart BMS Expansion Interface
  • Enables Parallel Use of Smart BMS
  • Includes CAN Cable, RS485 Cable, and GPS Cable (30CM each)
  • Compact and lightweight design
Product components: P-Link-CR-V2.0 board, CAN/RS485 cable, GPS cable

2. Setup and Installation

The P-Link-CR-V2.0 board is designed for straightforward integration with compatible JKBMS Smart BMS units. Proper installation is crucial for optimal performance.

Compatibility Requirements:

  • Smart BMS Version: Your JKBMS must be version V15 or higher.
  • Connector Type: Ensure your BMS is equipped with 4-pin RS485 and CANBUS connectors.
  • Protocol Confirmation: Verify that your BMS supports the necessary UART/CAN protocols. Refer to your BMS settings to confirm.
Important note about checking BMS RS485/CANBUS connectors (4-pin requirement)Kindly Note regarding BMS protocol compatibility (V15+, UART/CAN protocols)

Wiring Instructions:

The P-Link-CR board is suitable for parallel use of lithium battery protection boards. The specific wiring method is illustrated in the diagram below.

  1. Connect the provided CAN Cable and RS485 Cable to the corresponding ports on the P-Link-CR board and your Smart BMS.
  2. Ensure all connections are secure and follow the wiring diagram for correct parallel configuration.
  3. The standard cable length is 0.3 meters.
P-Link-CR Wiring Diagram for parallel use

Example connection to a BMS:

P-Link-CR connected to a BMS (general view)Close-up of P-Link-CR connection to BMS

Cable Diagram:

Detailed cable diagram for CAN/RS485 and GPS cables

3. Operating Instructions

Once the P-Link-CR-V2.0 board is correctly installed and connected to your Smart BMS, its operation is largely automatic, facilitating communication between parallel BMS units.

LED Indicator:

  • The board features a power indicator LED (D1).
  • When the device is activated and receiving power, the LED will be steady red.

Interface Definitions:

The following table details the pin definitions for the P-Link-CR board's connectors.

CouplerInterface NamePin NumberNameDefinition
P1GPS Interface1VGPSPower output, voltage close to B+
2TXGPRS_TX_G
3RXGPRS_RX_G
4GNDPower/signal ground
P2Communication Interface1RS485_PC_BRS485 signal negative terminal
2RS485_PC_ARS485 signal positive terminal
3CAN_HCAN signal positive terminal
4CAN_LCAN signal negative terminal
RS485-PC1,8,9,16RS485_PC_BRS485 signal negative terminal
2,7,10,15RS485_PC_ARS485 signal positive terminal
CAN4CAN_HCAN signal positive terminal
5CAN_LCAN signal negative terminal
RS485-EXT16,9RS485-EX-BRS485-EX-B
10,15RS485-EX-ARS485-EX-A

4. Maintenance

The P-Link-CR-V2.0 Communication Interface Board is a robust electronic component designed for durability. To ensure its longevity and reliable operation, follow these general maintenance guidelines:

  • Keep Dry: Protect the board from moisture and liquids. Water damage can lead to short circuits and component failure.
  • Keep Clean: Periodically inspect the board for dust or debris accumulation. Use a soft, dry brush or compressed air to gently clean the surface. Avoid using harsh chemicals or abrasive materials.
  • Avoid Physical Damage: Handle the board with care. Avoid dropping it or subjecting it to excessive force, which can damage the PCB or connectors.
  • Proper Storage: If storing the board for an extended period, keep it in an anti-static bag in a cool, dry environment.

No specific routine maintenance or calibration is required for this interface board.

5. Troubleshooting

If you encounter issues with your P-Link-CR-V2.0 board, consider the following troubleshooting steps:

  • No Power/LED Off:
    • Check all power connections to the BMS and ensure the BMS is powered on.
    • Verify that the P-Link-CR board is correctly seated in its connector.
  • Communication Issues:
    • Re-check all CAN, RS485, and GPS cable connections. Ensure they are firmly attached and correctly oriented according to the wiring diagram.
    • Confirm that your BMS meets the compatibility requirements (Version V15+ and 4-pin connectors).
    • Verify the BMS protocol settings as shown in the 'Kindly Note' image in the Setup section.
    • Inspect cables for any visible damage (cuts, pin bends).
  • Incorrect Parallel Operation:
    • Review the parallel wiring diagram carefully to ensure all connections are made as specified.
    • Consult your BMS user manual for specific instructions on configuring parallel operation.

If problems persist after following these steps, please refer to the 'Warranty and Support' section for further assistance.

6. Specifications

AttributeValue
Model NumberJK-P-Link-CR-V2.0
Brand NameJKBMS
Accessory TypeBattery Accessories, Communication Interface Board
Product FunctionCommunication Interface Board for Smart BMS Expansion
Works ForSMART BMS (Parallel Use)
Cables IncludedCAN Cable, RS485 Cable, GPS Cable
Cable Length30 CM (standard)
Dimensions (L x W x H)114.13mm × 24mm × 1.6mm
WeightApproximately 32g
OriginMainland China
CertificationCE, FCC, RoHS
Charger IncludedNo
Battery IncludedNo
High-concerned ChemicalNone
Product appearance, schematic, and connector diagram of P-Link-CRProduct size diagram with dimensions

7. User Tips

  • Verify BMS Compatibility: Always ensure your Smart BMS is version V15 or higher and has the required 4-pin RS485 and CANBUS connectors before purchasing or installing the P-Link-CR-V2.0 board.
  • Double-Check Wiring: Carefully follow the provided wiring diagrams for all connections, especially when setting up parallel BMS systems, to prevent damage and ensure proper communication.
  • Monitor LED Indicator: Use the red LED (D1) on the board as a quick visual check for power and activation status. A steady red light indicates proper power supply.
  • Consult BMS Manual: For specific configurations related to parallel operation or advanced communication settings, always refer to the detailed user manual of your primary Smart BMS.

8. Warranty and Support

For detailed warranty information and technical support, please contact the JKBMS Global Store directly. You may also find additional resources and the full operation and maintenance manual in PDF format at the following link:

User Manual (PDF): https://manuals.plus/m/8576c2a2cb91a77262a4b35dc2717ce20ecd18651b6ca1de1c4a9f94b43e35c7

When seeking support, please provide your product model (JK-P-Link-CR-V2.0) and a clear description of the issue you are experiencing.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.