Model: C-200 (Available in 50m, 100m, 200m ranges)

Digital Handheld Tape Measure with Red Laser

Introduction

The NJTY C-200 Laser Distance Meter is a professional measuring instrument designed for accurate and efficient distance, area, and volume calculations. Featuring a high-brightness red laser and multiple intelligent measurement modes, it is suitable for various applications in construction, renovation, and DIY projects. This manual provides essential information for safe and effective use of your device.

NJTY C-200 Laser Distance Meter with portable bag and lanyard
NJTY C-200 Laser Distance Meter with included portable bag and lanyard.

Safety Instructions

Please read these safety instructions carefully before using the instrument to prevent potential hazards, laser radiation damage, or electric shock.

  • Laser Radiation: This device uses a Class II laser (<1mW). Do not look directly at the laser beam at any time. Direct exposure can cause serious eye damage.
  • Optical Products: Do not use this product in conjunction with other optical instruments (e.g., binoculars, telescopes) as this can intensify the laser beam and increase the risk of eye injury.
  • Warning Labels: Do not remove or damage any safety warning signs or labels on the instrument.
  • Children: Keep the device out of reach of children.
  • Operating Environment: Use the device only in well-ventilated areas and avoid using it near flammable gases or liquids.

Parts List

The package should contain the following items:

  • 1x NJTY Laser Distance Meter (C-50, C-100, or C-200 model)
  • 1x Portable Lanyard
  • 1x Storage Bag
  • 1x User Manual (PDF version available online)
Contents of the NJTY Laser Distance Meter package
Included items in the package.

Setup

Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Slide or unclip the cover to open the compartment.
  3. Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery compartment cover securely.

Note: Batteries are not included in the package.

Operating Instructions

Device Overview

Labeled diagram of NJTY Laser Distance Meter buttons and display
Panel Introduction: Key buttons and display elements.
  • LED Display: Shows measurement results, mode indicators, battery level, and other information.
  • Power-on/Measurement Button (MEAS): Press to turn on the device, activate the laser, and initiate measurements.
  • Function Button (FUNC): Cycles through different measurement modes.
  • Addition & Subtraction Key (+/-): Used for adding or subtracting measurements.
  • Benchmark Unit Switch: Changes the measurement reference point (front or rear of the device).
  • Shutdown/Clear Key (CLEAR): Press briefly to clear the last measurement; press and hold to turn off the device.
  • Vertical/Horizontal Bubbles Level: Physical bubble levels for ensuring accurate horizontal and vertical alignment.

Power On/Off

  • Power On: Press the MEAS button. The device will turn on and the laser will activate.
  • Power Off: Press and hold the CLEAR button. The device will automatically shut down after 3 minutes of inactivity to save battery.
NJTY Laser Distance Meter showing automatic shutdown after 3 minutes
Automatic shutdown feature for power saving.

Measurement Modes

The device offers 7 intelligent measurement modes. Use the FUNC button to cycle through them.

Diagrams illustrating various measurement modes: Single, Continuous, Area, Volume, Pythagoras 2-point, Pythagoras 3-point
Visual guide to multiple measurement modes.
  1. Single Distance Measurement: Press MEAS to activate the laser, then press MEAS again to take a single distance measurement. The result is displayed immediately.
  2. Continuous Measurement (Min/Max): Select this mode and move the device. It will automatically calculate and display the maximum and minimum values during the measurement session.
  3. Area Measurement: Select this mode. Measure the length and width separately. The device will automatically calculate the area.
  4. Volume Measurement: Select this mode. Measure the length, height, and width sequentially. The device will automatically calculate the volume.
  5. Pythagoras (2-point): Used to measure vertical height indirectly. Measure the hypotenuse and one leg of a right triangle. The device calculates the other leg (height).
  6. Pythagoras (3-point): Used for more complex indirect height measurements, typically involving two hypotenuses and one common leg.
  7. Addition & Subtraction: After taking a measurement, use the +/- button to add or subtract subsequent measurements.

Unit Conversion

The device supports unit conversion between meters (m), feet (ft), and inches (in). Use the dedicated unit switch button to toggle between these units to suit your project requirements.

Data Storage

The device automatically records up to 30 groups of historical test data. Press the STO key (if available, or a dedicated memory button) to look up stored data, enhancing efficiency for work requiring data tracking.

NJTY Laser Distance Meter display showing 30 sets of data storage
Display showing stored data records.

Mute Mode

The device features a mute mode, useful in environments where sound alerts might be disruptive, such as libraries or quiet workspaces. Activate or deactivate mute mode using the dedicated sound/mute button (often integrated with the +/- key).

NJTY Laser Distance Meter in mute mode in a library setting
Using the device in mute mode.

Product Demonstration Video

Watch this video for a demonstration of the NJTY Laser Distance Meter's features and operation.

Maintenance

  • Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in its protective bag in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.
  • Lens Care: The high filter lens should be kept clean for accurate measurements. Use a soft lens cloth to gently clean the lens if necessary.
  • Environmental Protection: The device is IP54 rated for water and dust resistance, allowing stable operation in temperatures from -10℃ to 50℃. However, avoid prolonged exposure to extreme conditions.
NJTY Laser Distance Meter demonstrating IP54 waterproof and dustproof rating
The IP54 rating ensures durability against water splashes and dust.

Troubleshooting

Problem Possible Cause Solution
Device does not turn on. Low or dead batteries; incorrect battery installation; device damaged. Replace batteries with new ones, ensuring correct polarity. Check for physical damage.
Inaccurate measurements. Dirty lens; unstable measurement surface; obstruction in laser path; incorrect benchmark setting. Clean the lens. Ensure a stable surface. Clear any obstructions. Verify the benchmark setting (front/rear).
Device turns off unexpectedly during measurement. Automatic shutdown due to inactivity; low battery. Ensure continuous operation if needed, or replace batteries. The device has a 3-minute auto-shutdown feature.
Laser not visible or weak. Bright ambient light; low battery. Use in lower light conditions if possible. Replace batteries.

Specifications

Feature Detail
Brand Name NJTY
Laser Class Class II (<1mW)
Measurement Range 0.05-50m / 0.05-100m / 0.05-200m (depending on model)
Measurement Accuracy ±2mm (within 30m)
Dust and Waterproof Rating IP54
Automatic Power Off 3 minutes of inactivity
Data Storage 30 groups of data
Power Type Battery-Powered (2x 1.5V AAA batteries, not included)
Operating Temperature -10℃ ~ 50℃
Size 110*51*26MM
Certification CE, FCC, RoHS
Comparison of NJTY Laser Distance Meter models C-50, C-100, C-200 with different ranges
Available models with different measurement ranges.

User Tips

  • Verify Accuracy: For critical measurements, it's always a good practice to cross-reference with traditional tools like a caliper or tape measure, especially when first getting accustomed to the device. Users have reported high accuracy, often matching traditional tools to the millimeter.
  • Explore Features: Take time to familiarize yourself with all the measurement modes (area, volume, Pythagoras, continuous measurement) to maximize the device's utility. The device is compact and offers many features.
  • Battery Management: Be aware of the 3-minute automatic shutdown feature. If the device turns off during a measurement, it might be due to inactivity or low battery. Keep spare AAA batteries handy.
  • Read the Manual: If you're new to laser distance meters or specific features, a thorough read of the manual will help you understand all functions and ensure correct usage.

Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official NJTY website or contact your point of purchase. Keep your purchase receipt as proof of purchase.

A detailed user manual in PDF format is available for download from the manufacturer's website for comprehensive guidance.

© 2024 NJTY. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.