1. Product Overview
The JIKONG JK-PB2A16S15P is an intelligent Battery Management System (BMS) designed for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge, over-discharge, over-current, over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. This BMS is suitable for LiFePO4 and Li-ion battery types.
The protection board utilizes energy transfer active balancing technology, providing a continuous 2A balance current. This technology ensures battery consistency, extends battery life, and delays aging. The system includes a mobile APP (Android and iOS) for checking battery status, modifying parameters, and controlling charge/discharge switches via Bluetooth. Its compact size, simple operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power applications.
2. Functional Characteristics
The JIKONG JK-PB2A16S15P BMS offers a wide range of features:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- PC software operation support
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Information screen display support
- Accurate time logging
- RS485 communication support
- CAN communication support
- Heating function
- Alarm dry contact function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function
3. Setup and Installation
3.1. Packing List
Upon unboxing, verify that all components are present:
- Packing Box
- BMS Unit
- Interface Board
- Adapter
- RJ45 Network Cable (400mm)
- Switch (500mm)
- Heating Adapter Cable x1 (170mm)
- 8 Cells Total B+ Cable x1 (500mm)
- Sampling Line A (900mm)
- Sampling Line B (900mm)
- Sampling Line C (900mm)
- Adapter Cable A (300mm)
- Adapter Cable B (300mm)
- Adapter Cable C (300mm)
- 4.3LCD-TTL-P (Optional)

3.2. Wiring Diagrams
Proper wiring is crucial for the safe and correct operation of the BMS. Ensure all connections are secure and follow the diagrams below. The BMS supports 8-string to 16-string cell configurations.

The interface board provides various connection points:
- P1, P2, P3 Ports: Connect to the main BMS unit.
- UART Port: For communication with external devices or display.
- Display or Switch Port: For connecting an optional display or external switch.
- Heat Function Port: For connecting heating elements.
- RS485-2 Interface (8P8C RJ45 Socket): For parallel communication and connection to upper computer.
- RS485-1 Interface (8P8C RJ45 Socket): For communication with inverters.
- CAN Interface: For CAN bus communication.
- RS232 Interface (6P6C RJ11 Socket): For serial communication.
- Dry Interface: For external alarm or fan control.
- Dial Switch: For setting communication addresses in parallel configurations.
- Switch: General control switch.

3.3. Device Activation
Before powering on the protection board, ensure the balance cables are correctly connected, and the P- and B- terminals are properly wired. Confirm the protection board is securely fixed to the battery pack. Once verified, power on the BMS.
The BMS is designed for charger activation mode, meaning it will activate when a charger with a voltage 2V higher than the battery voltage is connected. Alternatively, it can be activated via a key switch or an optional display unit by inserting the cable into the display interface and pressing the button.3.4. APP Installation
The mobile APP for the JIKONG BMS allows for convenient monitoring and control. To install the APP, scan the QR code below. An Android device with version 7 or higher is required.

4. Operating Instructions
4.1. Active Equalization
The active equalization feature transfers energy from higher voltage cells to lower voltage cells to maintain battery consistency. Before using this function, set the battery parameters in the APP, including battery type, number of cells, battery capacity, trigger equalization differential pressure (default can be retained), voltage calibration, and current calibration. The default balance current is 2A for this model. It is recommended that the balance current not exceed 0.2C of the battery capacity. If not needed, the balancing switch can be turned off in the BMS control page of the APP.
4.2. Display Interface
The BMS has a reserved display interface. Users can connect an optional JIKONG display to conveniently view battery information.

4.3. Heating Function
The BMS includes a standard heating function to warm the battery in low-temperature conditions, preventing reduced activity and ensuring proper charging/discharging. The designed heating current is 10A. Users can control this function via the BMS control page in the APP. For extreme cold, it is recommended to install a normally closed temperature switch (45-65°C) in series with the heating circuit as a secondary safety measure.4.4. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or cooling fans. When the BMS detects an over-temperature, overcharge, or over-discharge state, the alarm interface can switch the dry contact status to trigger a buzzer or activate a fan. Users can configure two trigger conditions based on their specific needs.4.5. Communication Function
The BMS supports both CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications. There are two RS485 communication interfaces: RS485-1 for inverter communication and RS485-2 for parallel connection and upper computer communication. The default baud rate is 115200. Communication addresses can be set using the DIP switch (0-15).

4.6. Parallel Function
The parallel function allows up to 16 BMS units to be monitored simultaneously by an upper computer via the RS485 bus. To use this, you will need a USB to RS485 serial port cable and the JIKONG upper computer software. Each BMS must have a unique address set via the DIP switch (0 for host, 1-15 for slaves). The upper computer connects to the host BMS via the RS485-2 port, and slave BMS units are daisy-chained using RJ45 Ethernet cables.




5. Maintenance and Protection Features
The JIKONG BMS is equipped with various protection mechanisms to ensure the safety and longevity of your battery system. Most parameters are configurable via the APP.
5.1. Overcharge Protection and Recovery
The BMS protects against overcharging by shutting down charging when any cell voltage exceeds the set overcharge protection voltage. Charging resumes when all cell voltages drop below the overcharge recovery voltage.
5.2. Over-discharge Protection and Recovery
During discharge, if any cell voltage falls below the set undervoltage protection value, the BMS triggers protection and stops discharging. Discharge resumes when all cell voltages are charged above the undervoltage recovery voltage. The BMS will automatically shut down if any cell voltage drops below the automatic shutdown voltage.
5.3. Overcurrent Protection and Recovery (Charge & Discharge)
If the charging or discharging current exceeds the set continuous current for a specified delay time, the BMS will activate overcurrent protection and stop the respective operation. The operation resumes after the overcurrent release time has passed.
5.4. Overtemperature Protection and Recovery (Charge & Discharge)
The BMS monitors battery temperature. If the temperature exceeds the set overtemperature protection value during charging or discharging, the BMS will stop the operation. It will resume when the temperature falls below the recovery value.5.5. Low Temperature Protection and Recovery (Charge)
If the battery temperature drops below the set low temperature protection value during charging, the BMS will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the heating function is recommended.5.6. Short Circuit Protection and Recovery
The BMS provides short circuit protection. While the trigger current is not user-settable, the short circuit protection delay (µs) and recovery time (S) can be adjusted via the APP. If a short circuit occurs during initial charging or load connection, increasing the delay time can help prevent false triggers due to peak currents from the charger or capacitive loads.5.7. Intelligent Sleep
The intelligent sleep function can be enabled or disabled via the APP. It puts the BMS into a low-power standby mode if the charge/discharge current is less than 1A for 26 consecutive hours, reducing energy consumption. The BMS can be reactivated by pressing a button or connecting a charger.5.8. Emergency Switch
In case of issues like over-temperature, over-discharge, over-charge, or cell imbalance, activating the emergency switch in the APP will enable both charging and discharging for 30 minutes. This provides a temporary operational window to address critical situations, even if a single cell voltage has reached the automatic shutdown threshold.
6. Troubleshooting
This section provides guidance for common issues. For detailed diagnostics, refer to the full PDF manual.
6.1. LED Indicators
The BMS features LED indicators to communicate its status. Refer to the table below for interpretation:
| Status | RUN | ALM | L1-L6 | Description |
|---|---|---|---|---|
| Power Off | OFF | BMS is powered off. | ||
| Normal (Balance) | Flicker | OFF | Based on battery capacity | Normal operation, balancing active. |
| Normal (No Balance) | Flicker | OFF | Based on battery capacity | Normal operation, no balancing. |
| Charging (Overcurrent, Overtemp, Overvoltage, Failure) | Flicker | Flicker | Based on battery capacity | Charging protection active. |
| Discharging (Overcurrent, Overtemp, Undervoltage, Failure) | Flicker | Flicker | Based on battery capacity | Discharging protection active. |
| Other Alarms (Password not changed, Short circuit, Temperature) | Flicker | Flicker | Based on battery capacity | General alarm condition. |
Note: When the device address is set to 0 (host), the last LED indicator L6 blinks. If the value is set to other values (slave), the slave is off and blinks after successful communication with the host. ON indicates the LED is on, OFF indicates the LED is off.
6.2. Common Issues
- BMS not activating: Ensure all wiring is correct and secure. Verify that the charger voltage is at least 2V higher than the battery voltage for charger activation.
- Communication failure: Check all communication cables (RS485, CAN, Bluetooth). Verify DIP switch settings for correct addresses in parallel configurations. Ensure the correct protocol is selected in the APP/PC software.
- Unexpected shutdowns: Review APP/PC software logs for protection triggers (overvoltage, undervoltage, overcurrent, overtemperature, short circuit). Adjust parameters if necessary, but always prioritize safety.
- Balancing issues: Confirm battery parameters (cell count, capacity) are correctly set in the APP. Ensure the balancing function is enabled.
7. Specifications
The following table outlines the key specifications for the JIKONG JK-PB2A16S15P BMS:
| Parameter | Value | Unit |
|---|---|---|
| Brand Name | JIKONG | |
| Model | JK-PB2A16S15P | |
| Type | LiFePO4/Li-Ion Battery BMS | |
| Handware or Smart | SMART BMS | |
| Balance Function | Active Balanced BMS | |
| Max Balancing Current | 2 | A |
| Charging Current (Continuous) | 150 | A |
| Discharge Current (Continuous) | 150 | A |
| Max Instantaneous Current | 300 | A |
| Charge and Discharge Port | Common Port BMS | |
| Battery Strings Supported | 8S-16S | |
| Usage Scenario | Energy Storage BMS | |
| Certification | CE, FCC, RoHS | |
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Internal Loop Resistance | 0.45 | mΩ |
| Protective Plate Size | 300*100*24 | mm |
| Finished Weight | 1000 | g |
Default Parameters (LiFePO4)
| Parameter | Value | Unit |
|---|---|---|
| Balancing Initial Voltage | 3 | V |
| Maximum Balancing Current | 2 | A |
| Unit Overcharge Voltage | 3.6 | V |
| Single Overcharge Protection Recovery | 3.54 | V |
| Monomer Undervoltage Protection | 2.6 | V |
| Single Undervoltage Protection Recovery | 2.65 | V |
| Automatic Shutdown Voltage | 2.5 | V |
| SOC-0% Voltage | 2.6 | V |
| SOC-100% Voltage | 3.5 | V |
| Trigger Balancing Differential Pressure | 0.01 | V |
| Charging Overcurrent Protection Delay | 3 | S |
| Charge Overcurrent Protection Release Time | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | S |
| Short-circuit Protection Delay | 5 | µS |
| Short Circuit Protection Release Time | 30 | S |
| Charging Overtemperature Protection | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | °C |
| Discharge Overtemperature Protection | 70 | °C |
| Discharge Overtemperature Recovery | 60 | °C |
| Charging Low Temperature Protection | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | °C |
| MOS Overtemperature Protection | 100 | °C |
| MOS Overtemperature Recovery | 80 | °C |
| Device Address | 0 |

8. User Tips
- Verify Wiring Carefully: Double-check all balance cables and main power connections before initial power-up to prevent damage.
- Customize Parameters: Utilize the mobile APP or PC software to fine-tune protection parameters (e.g., overvoltage, overcurrent thresholds) to match your specific battery chemistry and application requirements.
- Monitor Regularly: Periodically check the battery status and logs via the APP or PC software to ensure optimal performance and identify any potential issues early.
- Consider Heating in Cold Climates: If operating in environments below 0°C, enable the heating function and consider adding an external temperature switch for enhanced battery protection.
- Parallel Setup Best Practices: When using multiple BMS units in parallel, ensure each unit has a unique address set via the DIP switches and follow the recommended RS485 daisy-chain wiring.
9. Warranty and Support
For warranty information and technical support, please contact JIKONG customer service or refer to the official product documentation. A comprehensive user manual in PDF format is available for download: JIKONG BMS User Manual (PDF).
10. Product Video
Watch this video for an unboxing and setup demonstration of the JIKONG Home Energy Storage BMS: