1. Product Overview
The JIKONG Lithium Battery Intelligent Protection Board (BMS) is a sophisticated management system designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and optional GPS remote capabilities.
This BMS is suitable for various lithium battery types, including LiFePO4 and ternary lithium batteries, and is widely applicable in battery packs for small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.
The protection board utilizes energy transfer active balancing technology, achieving a continuous balance current of 1A or 2A. This technology ensures battery consistency, extends battery range, and delays battery aging. A dedicated mobile application (APP) for Android and iOS allows users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth.
2. Specifications
2.1. General Specifications
| Attribute | Value |
|---|---|
| Brand Name | JIKONG |
| Type | LiFePO4 Battery BMS |
| Usage Scenario | Power BMS |
| Balance Function | Active Balanced BMS |
| Handware or Smart | SMART BMS |
| Charge and Discharge Port | Common Port BMS |
| Certification | CE, FCC, RoHS |
| High-concerned chemical | None |
| Function | Overcharge Protection, Over Discharge Protection, Overcurrent Protection, Short Circuit Protection |
2.2. Model-Specific Parameters
The JIKONG BMS is available in 150A and 200A versions. Key parameters are detailed below:
| Parameter | 150A Model (JK-BxAxxS-15P) | 200A Model (JK-BxAxxS-20P) | Unit |
|---|---|---|---|
| Supply Voltage | 20-100 | 20-100 | V |
| Operating Power Consumption | <800 | <800 | mW |
| Operating Temperature | -30-70 | -30-70 | °C |
| Max. Collection Strings | 24 | 24 | String |
| Max. Balancing Current | 1A / 2A | 2A | A |
| Max. Charging Current | 150 | 200 | A |
| Max. Discharge Current | 150 | 200 | A |
| Max. Instantaneous Current | 300 | 350 | A |
| Max. Internal Loop Resistance | 0.65 | 0.5 | mΩ |
| Protective Plate Size (L*W*H) | 162*102*20.4 | 162*102*20.4 | mm |
| Finished Weight | 430 | 430 | g |
2.3. Product Dimensions
2.4. Default Parameters
Default parameters vary based on battery chemistry (Li-Ion, LiFePO4, LTO). These can be adjusted via the APP.
| Parameter | Li-Ion (Default) | LiFePO4 (Default) | LTO (Default) | Unit |
|---|---|---|---|---|
| Balancing Initial Voltage | 3 | 3 | 2 | V |
| Max. Balancing Current | 1A / 2A | 1A / 2A | 1A / 2A | A |
| Unit Overcharge Voltage | 4.2 | 3.6 | 2.7 | V |
| Single Overcharge Protection Recovery | 4.18 | 3.55 | 2.65 | V |
| Monomer Undervoltage Protection | 2.82 | 2.6 | 1.8 | V |
| Single Undervoltage Protection Recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic Shutdown Voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% Voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% Voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger Balancing Differential Pressure | 0.01 | 0.01 | 0.01 | V |
| Charging Overcurrent Protection Delay | 30 | 30 | 30 | S |
| Charge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Discharge Overcurrent Protection Delay | 300 | 300 | 300 | S |
| Discharge Overcurrent Protection Release Time | 60 | 60 | 60 | S |
| Short-circuit Protection Delay | 1500 | 1500 | 1500 | µS |
| Short-circuit Protection Release Time | 60 | 60 | 60 | S |
| Charging Overtemperature Protection | 70 | 70 | 70 | °C |
| Charge Overtemperature Restore Temperature | 60 | 60 | 60 | °C |
| Discharge Overtemperature Protection | 70 | 70 | 70 | °C |
| Discharge Overtemperature Recovery | 60 | 60 | 60 | °C |
| Charging Low Temperature Protection | -20 | -20 | -20 | °C |
| Charge Low Temperature Restore Temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature Protection | 100 | 100 | 100 | °C |
| MOS Overtemperature Recovery | 80 | 80 | 80 | °C |
| Device Address | 0 | 0 | 0 | / |
| Discharge Precharge Time | 0 | 0 | 0 | S |
3. Setup and Installation
3.1. Unpacking and Inspection
Upon receiving your JIKONG JK BMS, carefully inspect the packaging for any signs of impact or damage. Handle the protection board gently and avoid inverting it. Ensure all components listed in the packing list are present:
- BMS Unit x1
- NTC (400mm) x1
- Balance Wires (750mm) x1
- Switch (500mm) x1
- Packing Box x1
3.2. Interface Definition
The BMS features various interfaces for connection and communication:
Detailed pin definitions for the connectors are provided below. Ensure correct wiring to prevent damage.
P1 XH-15AW Connector (Balance and Acquisition Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | B- | Total negative battery |
| 2 | B1 | The first battery positive |
| 3 | B2 | The second battery positive |
| ... | ... | ... |
| 14 | B13 | The thirteenth battery positive |
| 15 | B14 | The fourteenth battery positive |
P2 XH-11AW Connector (Balance and Acquisition Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | B15 | The fifteenth battery positive |
| ... | ... | ... |
| 7 | B21 | The twenty-first battery positive |
| 8 | B22 | The twenty-second battery positive |
| 9 | B23 | The twenty-third battery positive |
| 10 | B24 | The twenty-fourth battery positive, Total battery positive |
| 11 | B+ | Protection board power supply, connected to the battery |
P3 XH-4AW Connector (Temperature Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | T1A | First temperature sensor pin A |
| 2 | T1B | First temperature sensor pin B |
| 3 | T2A | Second temperature sensor pin A |
| 4 | T2B | Second temperature sensor pin B |
P4 A1254WF-3A Connector (Communication Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | DN | CAN_L/RS485-B signal negative |
| 2 | DP | CAN_H/RS485-A signal positive |
| 3 | GND | Signal ground |
P5 1.25T-4PWT Connector (GPS Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | VGPS | Power output, the voltage is close to B+ |
| 2 | TX | UART_TX, 3.3V |
| 3 | RX | UART_RX, 3.3V |
| 4 | GND | Power/signal ground |
P6 A1254WF-6A Connector (Display Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 1 | VCC | Display power output |
| 2 | A | The display RS485 signal is positive |
| 3 | B | Display RS485 signal negative |
| 4 | GND | Negative terminal |
P7 A1254WF-7A Connector (Heating Interface)
| Pin Number | Name | Definition |
|---|---|---|
| 5 | K+ | Activate the positive signal |
| 6 | K- | Activation signal negative electrode |
| 1 | HT- | Heater element negative electrode |
| 6 | CD+ | Charge indication input positive terminal |
| 7 | CD- | Charge indication input negative terminal |
D1 Bluetooth Connection Indicator: When Bluetooth is connected to the protection board, the indicator is steady on. When the connection is disconnected, the indicator blinks.
P- Terminal: Connect to external load or negative terminal of charger.
B- Terminal: Connect to the negative battery terminal.
3.3. Wiring Diagram
The JIKONG JK BMS is compatible with 7-24 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. A general wiring diagram for a 24S configuration is shown below. Always ensure correct polarity and connections.
4. Operating Instructions
4.1. APP Installation and Device Activation
To utilize the full features of your JIKONG JK BMS, install the mobile APP. The APP supports Android (version 7 minimum required) and iOS operating systems. Search for "JIKONG SMART BMS" in your app store or scan the QR code provided in the product documentation (if available) to download.
Device Activation: Before powering on the protection board, double-check that the balance cables are properly connected and that the P- and B- terminals are correctly wired. Ensure the protection board is securely fixed to the battery pack. The BMS does not have a physical power-on switch. It is designed for charging activation mode, meaning it will activate when a charger (with voltage 2V higher than battery voltage) is connected after battery assembly. For models with a display screen and button, activation can also be achieved by inserting the display cable and pressing the button.
4.2. Functional Characteristics
The JIKONG JK BMS offers a wide range of functions for optimal battery management:
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485/CAN (one of two, optional)
- Support heating function (optional)
- Support GPS communication (optional)
- Discharge precharge function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
4.3. Detailed Function Descriptions
4.3.1. Active Equalization
The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring battery consistency. Before using this function, set basic battery parameters (battery type, cell count, capacity, trigger differential pressure, voltage/current calibration) in the APP. The default balance current is 1A/2A, adjustable via the APP. It is recommended that the balance current does not exceed 0.2C of the battery capacity. The balancing function can be enabled or disabled via the APP.
4.3.2. GPS and Display Interface
The BMS includes a reserved GPS port for optional GPS modules, allowing for battery location tracking. It also features a display interface for connecting an external display screen (available from JIKONG) to view battery information.
4.3.3. Heating Function (Optional)
For low-temperature environments, an optional heating function can be used with a resistance heater or heating film to warm the battery, preventing reduced activity and ensuring proper charging/discharging. The designed heating current is 4A. Users can control this function via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed) in series as a secondary safety measure.
4.3.4. Charge Overvoltage Protection and Recovery
The BMS provides standard charge overvoltage protection. Users can set the single cell overcharge protection voltage and recovery voltage in the APP. If any cell exceeds the set voltage during charging, the BMS will stop charging. Charging resumes when all cells fall below the recovery voltage.
4.3.5. Discharge Undervoltage Protection and Recovery
Standard discharge undervoltage protection is included. Users can set the undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell drops below the set undervoltage protection voltage during discharge, the BMS will trigger protection and stop discharging. Discharge resumes when all cells are above the recovery voltage. If any cell drops below the automatic shutdown voltage, the BMS will shut down to protect the battery.
4.3.6. Charge Overcurrent Protection and Recovery
The BMS features standard charge overcurrent protection. Users can set the continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set limit for the specified delay, the BMS will stop charging. Charging resumes after the recovery time.
4.3.7. Discharge Overcurrent Protection and Recovery
Standard discharge overcurrent protection is provided. Users can set the continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set limit for the specified delay, the BMS will stop discharging. Discharge resumes after the recovery time. (Note: Maximum continuous discharge current cannot exceed the nominal current of 150A/200A).
4.3.8. Overtemperature Protection and Recovery
The BMS includes standard charge and discharge overtemperature protection. Users can set protection and recovery temperatures for both charging and discharging in the APP. If the battery temperature exceeds the set limit, the BMS will stop the respective operation (charging or discharging). The operation resumes when the temperature falls below the recovery threshold.
4.3.9. Low Temperature Protection and Recovery
Standard charging low temperature protection is included. Users can set the charging low temperature protection and recovery temperatures in the APP. If the battery temperature drops below the set limit, the BMS will stop charging. Charging resumes when the temperature rises above the recovery threshold. For extremely cold areas, the optional heating function is recommended.
4.3.10. Short Circuit Protection and Recovery
The BMS is equipped with standard short circuit protection. While the trigger current is fixed, users can adjust the short circuit protection delay (µS) and recovery time (S) in the APP. If a short circuit occurs, the BMS will trigger protection. If the protection triggers upon initial connection of a charger or load, increasing the delay time may resolve it, especially if large capacitors in the load cause high inrush currents.
4.3.11. Discharge Precharge Function
The BMS includes a standard discharge precharge function with a default time of 5 seconds. Users can enable or disable this function via the APP. Setting the precharge time to 0 disables the function.
4.3.12. Emergency Switch
A standard emergency switch function is available. If issues like over-temperature, over-discharge, overcharge, or cell string drops occur during normal use, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes, providing emergency operational time. The BMS will continue to operate for this period even if a single cell reaches automatic shutdown voltage.
4.3.13. Intelligent Sleep
The BMS features an intelligent sleep function, which can be enabled or disabled via the APP. Its purpose is to put the protection board into a low-power state when idle (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated by pressing a button (if equipped) or connecting a charger.
4.3.14. Communication Function
The BMS supports optional CAN/RS485 communication. Users can select CAN or RS485 via the APP's BMS control page. The address and communication protocol can be configured according to specific requirements. Refer to the JIKONG Protection Board communication protocol document for details.
5. Maintenance
Regular maintenance helps ensure the longevity and optimal performance of your JIKONG JK BMS:
- Visual Inspection: Periodically check all wiring and connections for signs of wear, corrosion, or loose contacts. Ensure the BMS is securely mounted.
- Software Monitoring: Use the JIKONG mobile APP to regularly monitor battery parameters, cell voltages, temperatures, and protection statuses. This helps identify potential issues early.
- Parameter Review: Occasionally review the BMS parameters in the APP to ensure they are still appropriate for your battery pack's condition and usage patterns.
- Firmware Updates: Check with JIKONG for any available firmware updates for your BMS model, which may offer improved performance or new features.
- Cleaning: Keep the BMS unit clean and free from dust and debris to ensure proper heat dissipation. Use a soft, dry cloth for cleaning.
6. Troubleshooting
The JIKONG JK BMS is designed with multiple protection features. If the system stops functioning or exhibits abnormal behavior, check the following:
- Protection Triggered: If the BMS stops charging or discharging, check the APP for any active protection alerts (e.g., overvoltage, undervoltage, overcurrent, overtemperature, short circuit). Address the root cause of the protection.
- Wiring Issues: Verify all balance wires, main power cables (P- and B-), and communication cables are correctly and securely connected. Loose connections can cause erratic behavior or prevent activation.
- Activation Failure: If the BMS does not activate after initial connection, ensure the charger voltage is at least 2V higher than the battery voltage. For models with a button, try pressing it after connecting the display.
- APP Connectivity: If the APP cannot connect via Bluetooth, ensure Bluetooth is enabled on your device and the BMS is powered on. Try restarting the APP or the BMS.
- Parameter Settings: Incorrect parameter settings can lead to unexpected behavior. Review your settings in the APP, especially those related to voltage, current, and temperature limits, and ensure they match your battery specifications.
- Short Circuit Protection: If short circuit protection triggers frequently, especially upon connecting a load or charger, consider increasing the short circuit protection delay in the APP settings. Ensure there are no actual short circuits in your wiring.
For persistent issues not resolved by these steps, contact JIKONG technical support.
7. User Tips
No specific user tips from reviews or Q&A were provided for this product. However, general best practices for BMS usage include:
- Always ensure all connections are tight and properly insulated to prevent short circuits and ensure reliable operation.
- Regularly monitor your battery pack's health via the mobile APP, paying close attention to individual cell voltages and temperatures.
- When configuring parameters, always refer to your battery cell manufacturer's specifications to avoid setting values that could damage your battery.
- For systems operating in extreme temperatures, consider utilizing the optional heating function to maintain optimal battery performance and lifespan.
8. Warranty and Support
For warranty information, technical support, or service inquiries, please contact JIKONG directly or the authorized reseller from whom you purchased the product. Keep your proof of purchase for warranty claims.