1. Introduction

The JIKONG Lithium battery intelligent protection board (BMS) is a sophisticated management system designed for large capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection. Additionally, it features a coulomb meter, Bluetooth communication, and optional GPS remote capabilities. This BMS is compatible with various battery types, including Lithium Iron Phosphate (LiFePO4) and Ternary Lithium (Li-ion) batteries.

Utilizing energy transfer active balancing technology with independent intellectual property rights, the protection board achieves a continuous balance current of 1A/2A. This high-current active equalization ensures battery consistency, extends battery range, and delays battery aging. The system is supported by a mobile APP (Android and iOS) that connects via Bluetooth, allowing users to monitor battery status, modify parameters, and control charge/discharge switches. Its compact size, ease of operation, and comprehensive functionality make it suitable for a wide range of applications, including small sightseeing vehicles, mobility scooters, shared cars, high-power energy storage systems, base station backup power supplies, and solar power stations.

JIKONG JK BMS front view
Figure 1: JIKONG JK BMS Front View
JIKONG JK BMS angled view
Figure 2: JIKONG JK BMS Angled View

2. Specifications

The JIKONG BMS is available in 150A and 200A versions, each with specific parameters. The following tables detail the main parameters and default settings.

2.1. Main Parameters (150A Protection Board)

Parameter Value Unit
Supply Voltage20-100V
Operating Power Consumption<800mW
Operating Temperature-30-70°C
Max Number of Collection Strings24Strings
Max Balancing Current1 or 2A
Max Charging Current150A
Max Discharge Current150A
Max Instantaneous Current300A
Max Internal Loop Resistance0.65mΩ
Protective Plate Size (L×W×H)162×102×20.4mm
Finished Weight430g

2.2. Main Parameters (200A Protection Board)

Parameter Value Unit
Supply Voltage20-100V
Operating Power Consumption<800mW
Operating Temperature-30-70°C
Max Number of Collection Strings24Strings
Max Balancing Current2A
Max Charging Current200A
Max Discharge Current200A
Max Instantaneous Current350A
Max Internal Loop Resistance0.5mΩ
Protective Plate Size (L×W×H)162×102×20.4mm
Finished Weight430g

2.3. Product Dimensions

The dimensions for the JK-BxAxxS-15P/20P series protection board are 162mm (length) × 102mm (width) × 20.4mm (height).

JIKONG JK BMS dimensions diagram
Figure 3: JIKONG JK BMS Dimensions
JIKONG JK BMS B1A20S15P specifications
Figure 4: JK-B1A20S15P Specific Parameters

3. Setup and Installation

3.1. Unpacking and Inspection

Upon receiving the product, handle the packaging and the protection board gently. Avoid inverting the package. Before opening, inspect the package for any signs of impact or damage. The package contents typically include:

  • BMS unit ×1
  • NTC temperature sensor ×1 (400mm long)
  • Balance Wires ×1 (750mm)
  • Switch ×1 (500mm)
  • Packing box ×1
JIKONG JK BMS package contents
Figure 5: Package Contents

3.2. Wiring Diagram

The JK-BxAxxS-15P/20P series protection board is suitable for 7-24 series lithium battery packs. The wiring method varies depending on the number of cells in the battery pack. Ensure all connections are secure and correct before powering on the BMS.

JIKONG JK BMS 24S wiring diagram
Figure 6: JK-BxAxxS-15P/20P-24S Wiring Diagram

3.3. Interface Definition

The BMS features various interfaces for connection and communication:

  • P1 (XH-15AW) Balance and Acquisition Interface: Connects to individual battery cell positive terminals (B1 to B24) and the total negative terminal (B-).
  • P3 (XH-4AW) Temperature Interface: Connects to NTC temperature sensors (T1A, T1B, T2A, T2B).
  • P4 (A1254WF-3A) Communication Interface: For CAN/RS485 communication (DN, DP, GND).
  • P5 (1.25T-4PWT) GPS Interface: For optional GPS module connection (VGPS, TX, RX, GND).
  • P6 (A1254WF-6A) Display Interface: For optional display screen connection (VCC, A, B, GND).
  • P7 (A1254WT-7A) Heating Interface: For connecting heating elements (HT-) and charge indication (CD+, CD-).
  • D1: Bluetooth connection indicator LED.
  • P-: Connects to external load or negative terminal of charger.
  • B-: Connects to the negative battery terminal.
JIKONG JK BMS interface connections
Figure 7: BMS Interface Overview
JIKONG JK BMS rich interface diagram
Figure 8: Rich Interface for Daily Needs

3.4. Device Activation

Before powering on the protection board, ensure that the balance cables are properly connected and that P- and B- are correctly wired. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.

The protection board does not have a power-on control switch. It is designed for charging activation: the charger voltage must be 2V higher than the battery voltage. After battery assembly, connect the charger to activate the protection board.

Alternatively, the protection board supports key activation and display activation. If you have an optional display screen and button, simply insert the cable into the display interface and press the button to activate the BMS.

4. Operation

4.1. APP Installation and Usage

The JIKONG BMS can be controlled and monitored via a mobile APP available for Android (version 7 minimum) and iOS. Scan the QR code below to download the APP.

JIKONG APP QR code
Figure 9: Mobile APP Link QR Code

The APP allows you to:

  • Monitor battery working status.
  • Modify protection board parameters.
  • Control charge and discharge switches.
  • View multi-screen display and data connection.
JIKONG APP multi-screen display
Figure 10: Multi-screen Display and Data Connection via APP/PC Software/LCD

4.2. Active Equalization

The BMS employs active equalization to transfer energy from higher voltage cells to lower voltage cells, ensuring voltage balance. Before using this function, set the basic battery parameters (battery type, number of cells, capacity, trigger equalization differential pressure, voltage calibration, current calibration) in the APP. The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). Equalization automatically activates when the voltage difference between any two battery strings exceeds the set value and turns off when it falls below the set value. If not needed, the equalization switch can be turned off in the BMS control page of the APP.

Active Balancing (Lossless Balancing) diagram
Figure 11: Active Balancing Principle

4.3. Heating Function

The BMS supports an optional heating function for low-temperature environments. A resistance heater or heating film warms the battery to prevent reduced activity and charging/discharging issues. The designed heating current is 4A. Users can switch this function on/off via the APP based on ambient temperature. It is recommended to install a temperature control switch (45°C to 65°C normally closed) in series with the heating circuit as a secondary protection to prevent thermal runaway.

4.4. Communication Function

The BMS supports optional CAN/RS485 communication. Users can select CAN or RS485 for multiplexed ports in the APP's BMS control page. The address and communication protocol can be configured according to specific requirements and scenarios. Refer to the Jikong Protection Board communication protocol document for details.

4.5. GPS and Display Interface

The BMS includes reserved GPS and display interfaces. Users can connect an optional GPS module for battery location tracking and an optional display screen to view battery information, customizing according to their needs.

4.6. Intelligent Sleep

The intelligent sleep function is standard and can be enabled/disabled via the APP. Its purpose is to reduce the BMS's self-consumption by shutting down when the board is in standby (charging/discharging current less than 1A for 26 consecutive hours). The BMS can be reactivated by pressing a button or connecting a charger.

4.7. Emergency Switch

A standard emergency switch function is available. If issues like over-temperature, over-discharge, over-charge, or string drops occur during normal use, activating the emergency switch in the APP's BMS control page will enable charge and discharge for 30 minutes. This provides emergency operating time, even if a single cell reaches automatic shutdown voltage, preventing critical failures during operation.

4.8. Discharge Precharge Function

The discharge precharge function is standard, with a default precharge time of 5 seconds. Users can enable/disable or adjust the precharge time as needed. Setting the precharge time to 0 disables the function.

4.9. Parameter Setting

Detailed parameter settings are available within the mobile APP. Users can customize various protection thresholds and operational parameters to match their specific battery configuration and application requirements. Refer to the "Instructions for Setting Protection Board Parameters" within the APP for comprehensive guidance.

5. Protection Features

The JIKONG BMS provides comprehensive protection features to ensure the safety and longevity of your battery pack. These protections are automatically managed by the BMS based on configured parameters.

JIKONG JK BMS functional characteristics
Figure 12: Functional Characteristics and Protections

5.1. Overcharge Protection and Recovery

The BMS includes standard overcharge protection. Users can set the single cell overcharge protection voltage and recovery voltage via the APP. If any cell's voltage exceeds the set overcharge protection during charging, the BMS will stop charging. Charging resumes when all cell voltages fall below the recovery voltage, preventing cell damage from overcharging.

5.2. Discharge Undervoltage Protection and Recovery

Standard discharge undervoltage protection is provided. Users can set the battery undervoltage protection voltage, recovery voltage, and automatic shutdown voltage in the APP. If any cell's voltage drops below the protection threshold during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the recovery voltage. If any cell's voltage falls below the automatic shutdown voltage, the BMS will automatically shut down to protect the battery.

5.3. Charge Overcurrent Protection and Recovery

The BMS features standard charge overcurrent protection. Users can set the continuous charging current, overcurrent delay, and recovery time in the APP. If the charging current exceeds the set continuous current for the specified delay, the BMS will stop charging. Charging resumes after the overcurrent recovery time has passed.

5.4. Discharge Overcurrent Protection and Recovery

Standard discharge overcurrent protection is included. Users can set the continuous discharge current, overcurrent delay, and recovery time in the APP. If the discharge current exceeds the set continuous current for the specified delay, the BMS will stop discharging. Discharge resumes after the overcurrent recovery time. Note: The maximum continuous discharge current should not exceed the nominal current (150A/200A).

5.5. Overtemperature Protection and Recovery

The BMS provides standard charge and discharge overtemperature protection. Users can set the overtemperature protection and recovery thresholds for both charging and discharging in the APP. If the battery temperature exceeds the set limit, the BMS will stop the respective operation (charging or discharging). Operation resumes when the temperature falls below the recovery threshold.

5.6. Low Temperature Protection and Recovery

Standard charging low temperature protection is included. Users can set the low temperature protection and recovery thresholds for charging in the APP. If the battery temperature drops below the set limit, the BMS will stop charging. Charging resumes when the temperature rises above the recovery threshold. For extremely cold environments, using the optional heating function is recommended.

5.7. Short Circuit Protection and Recovery

The BMS is equipped with standard short circuit protection. Users can set the short circuit protection delay and recovery time in the APP. If a short circuit is detected, the BMS will activate protection. If a short circuit occurs during initial charging or loading due to high peak currents (e.g., from charger turn-on or load capacitance), increasing the short circuit protection delay may resolve the issue. The BMS will resume operation after the short circuit recovery time.

6. Troubleshooting

This section addresses common issues and their potential solutions.

6.1. Battery Draining When Idle

Issue: The BMS appears to drain the battery when left idle for an extended period (e.g., a month).

Possible Cause: The BMS might be consuming power in standby mode, or the intelligent sleep function is not activated or configured correctly.

Solution:

  1. Activate Intelligent Sleep: Ensure the intelligent sleep function is enabled in the mobile APP. This function is designed to reduce the BMS's self-consumption by shutting down when the charging/discharging current is less than 1A for 26 consecutive hours.
  2. Check for Parasitic Loads: Verify that there are no other devices or connections drawing power from the battery when the system is idle.
  3. BMS Reactivation: If the BMS enters intelligent sleep, it can be reactivated by pressing a connected button or by connecting a charger.

7. User Tips

  • For long-term storage or periods of inactivity, ensure the intelligent sleep function is enabled to minimize battery drain.
  • Always double-check all wiring connections, especially balance cables and main power lines (P- and B-), before activating the BMS to prevent damage.
  • Utilize the mobile APP for real-time monitoring and fine-tuning of parameters to optimize battery performance and lifespan for your specific application.
  • In cold climates, consider using the optional heating function to maintain optimal battery temperature and prevent performance degradation.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.