1. Introduction
The NJTY JD05 and JD05K are advanced handheld non-contact infrared thermometers designed for accurate temperature measurement across various applications. The JD05K model further enhances functionality with a K-Type probe for contact temperature measurement and ambient humidity detection.
These devices offer quick 0.5-second readings, adjustable emissivity, and a clear display, making them suitable for professionals and enthusiasts alike in fields such as HVAC, electrical work, automotive maintenance, and cooking.
Video: Overview of NJTY K-Type Thermometer features and usage examples, including measurement modes, laser, unit switching, and temperature tests.
2. Safety Information
WARNING: This equipment contains a Class II laser product.
- Do not look directly into the laser beam.
- Do not use a mirror or any reflective surface to view the laser beam.
- Do not shine the laser on other people or animals, as the laser beam may harm eyes.
- Avoid rapid changes in ambient temperature or thermal shock, as this can affect sensor stability. Allow approximately 30 minutes for the device to stabilize and function properly after significant temperature changes.
- The infrared thermometer measures surface temperature and cannot measure temperature through glass or other transparent surfaces.
- Accuracy of internal temperature measurement may be affected by environmental factors such as vapors, dust, and smoke.
3. Product Overview
3.1 Components and Display
The thermometer features an ergonomic design for comfortable handling. Key components and display elements are illustrated below:

Image: Panel Introduction of the NJTY Infrared Thermometer, highlighting Humidity window, Display screen, Laser light on/off button, Temperature Unit Symbol, MODE menu button, Probe socket, Temperature sub-display, Power button, Laser aiming, Infrared sensor detection port, and Battery compartment.
- Humidity Window: (JD05K only) Sensor for ambient humidity.
- Display Screen: Shows temperature readings, mode indicators, battery status, and humidity (JD05K). JD05K features a high-definition green backlit display, while JD05 has a black screen.
- Laser Light On/Off Button: Activates/deactivates the laser pointer for targeting.
- Temperature Unit Symbol (°C/°F): Indicates the selected temperature unit.
- MODE Menu Button: Cycles through measurement modes (MAX/MIN for JD05K, HAL/LAL/MAX/MIN for JD05).
- IR/PR Button: (JD05K only) Switches between Infrared and K-Type Probe measurement modes.
- Probe Socket: (JD05K only) Port for connecting the K-Type thermocouple probe.
- Power Button (Trigger): Activates the device and initiates measurement.
- Laser Aiming: Emits a laser dot for precise targeting of the measurement area.
- Infrared Sensor Detection Port: Collects infrared radiation for non-contact temperature measurement.
- Battery Compartment: Houses the AAA batteries.
3.2 Model Differences

Image: Comparison between Model JD05K (with K-Type Thermocouple and RH% humidity measurement) and Model JD05 (Infrared Thermometer only).
- Model JD05K: Features both Infrared and K-Type Thermocouple temperature measurement, along with ambient humidity (RH%) detection. It has a high-definition green backlit display.
- Model JD05: Offers Infrared temperature measurement only and has a black screen display.
4. Specifications

Image: Detailed parameter comparison table for NJTY JD05K and JD05 models.
| Feature | JD05K | JD05 |
|---|---|---|
| Infrared Temperature Range | -50℃ ~ 800℃ (-58°F ~ 1472°F) | -50℃ ~ 800℃ (-58°F ~ 1472°F) |
| K-Type Temperature Range | -50℃ ~ 300℃ (-58°F ~ 572°F) | N/A |
| Humidity Range | 5% ~ 99% RH | N/A |
| Function Selection | MAX/MIN | HAL/LAL/MAX/MIN |
| Backlight Screen | Backlit Display (Green) | Black Display |
| Distance Spot Ratio (D:S) | 12:1 | 12:1 |
| Emissivity | 0.10 - 0.99 Adjustable | 0.10 - 0.99 Adjustable |
| Measurement Accuracy | ≥ 100℃, ± 2% / ≤ 100℃, ± 2℃ | ≥ 100℃, ± 2% / ≤ 100℃, ± 2℃ |
| Response Time | 0.5s | 0.5s |
| Auto Power Off | About 15s | About 15s |
| Unit Selection | °C/°F | °C/°F |
| Resolution | 0.1℃ (0.1°F) | 0.1℃ (0.1°F) |
| Mute Function | No | Yes |
| High and Low Temperature Alarm | Yes | No |
| Low Battery Indicator | Yes | Yes |
| Operating Temperature | 0℃ - 50℃ (32 ~ 122°F) | 0℃ - 50℃ (32 ~ 122°F) |
| Power Supply | 2x 1.5V AAA Battery (not included) | 2x 1.5V AAA Battery (not included) |
| Certifications | CE, RoHS | CE, RoHS |
4.1 Distance Spot Ratio (D:S)
The Distance-to-Spot Ratio (D:S) is 12:1 for both models. This ratio indicates that for every 12 units of distance from the target, the measurement spot diameter is 1 unit. For example, if the thermometer is 360mm away from the target, it will measure the average temperature of a 30mm diameter spot.

Image: Diagram explaining the 12:1 Distance Spot Ratio (D:S), where D is Measurement Distance and S is Diameter of Measured Object.
5. Setup
5.1 Battery Installation
- Locate the battery compartment on the handle of the thermometer.
- Open the battery compartment cover.
- Insert two (2) 1.5V AAA batteries, ensuring correct polarity (+/-).
- Close the battery compartment cover securely.
Note: Batteries are not included with the product.
6. Operating Instructions
6.1 Power On/Off
To power on the device, simply press the trigger. The display will illuminate. The device will automatically shut off after approximately 15 seconds of inactivity to conserve battery life.
6.2 Infrared Temperature Measurement (Both JD05 & JD05K)
- Point the infrared sensor detection port towards the target object.
- Press and hold the trigger. The laser pointer will activate (if enabled) to help aim.
- The temperature reading will be displayed on the screen. Release the trigger to hold the reading.

Image: Various applications of the infrared thermometer, including heating equipment, freezers, automotive, and industrial use.
6.3 K-Type Probe Temperature Measurement (JD05K Only)
- Insert the K-Type thermocouple probe into the probe socket on the side of the device.
- Press the "IR/PR" button to switch the measurement mode to K-Type probe. The display will indicate probe mode.
- Carefully immerse the metal tip of the probe into the substance or onto the surface you wish to measure.
- The temperature reading from the probe will be displayed on the screen.

Image: Demonstration of K-Type probe temperature measurement in a liquid.
6.4 Humidity Measurement (JD05K Only)
The JD05K model continuously displays the ambient relative humidity (RH%) on the screen, typically in the lower left corner.

Image: Close-up of the JD05K display showing humidity percentage.
6.5 Unit Switching (°C/°F)
Press the "°C/°F" button to toggle between Celsius and Fahrenheit temperature units.
6.6 Laser On/Off
Press the laser button (triangle icon) to turn the laser pointer on or off. The laser helps in precise targeting but can be disabled if not needed.
6.7 Mode Button (MAX/MIN, HAL/LAL)
Press the "MODE" button to cycle through various display modes:
- MAX/MIN: Displays the maximum or minimum temperature recorded during a measurement session (available on both models).
- HAL (High Alarm Limit) / LAL (Low Alarm Limit): (JD05 only) Allows setting high and low temperature alarms. When the measured temperature exceeds these limits, an alarm will sound.
6.8 Emissivity Adjustment
Emissivity (E) is a measure of an object's ability to emit infrared energy. Different materials have different emissivities. For accurate non-contact temperature measurement, adjust the emissivity setting (0.10-0.99) to match the target material. The default value is 0.95, suitable for most organic materials and painted surfaces. Consult an emissivity table for specific materials if higher accuracy is required.
Use the arrow buttons (if available, or specific mode button combinations) to adjust the emissivity value on the display.
7. Maintenance
- Keep the device clean and dry. Use a soft, damp cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Ensure the infrared sensor lens and display screen are free from dust and debris for accurate readings.
- When not in use for extended periods, remove the batteries to prevent leakage.
- Store the thermometer in a cool, dry place, away from direct sunlight and extreme temperatures.
- Handle the K-Type probe (if applicable) with care to prevent bending or damage.

Image: NJTY JD05K Thermometer with its protective carrying case.
8. Troubleshooting
- Inaccurate Readings / Unstable Sensor: If the device has been exposed to significant changes in ambient temperature (thermal shock), the sensor may become unstable. Allow the thermometer to acclimate to the new environment for approximately 30 minutes before taking measurements.
- Cannot Measure Through Glass: Infrared thermometers measure surface temperature and cannot penetrate glass. To measure the temperature of an object behind glass, measure the glass surface itself or use the K-Type probe (JD05K) if direct contact is possible.
- Readings Affected by Environment: Vapors, dust, or smoke between the thermometer and the target can interfere with infrared measurements. Ensure a clear line of sight to the target.
- No Display / Device Not Turning On: Check battery installation and ensure batteries are not depleted. Replace with fresh AAA batteries if necessary.
9. User Tips
- Infrared vs. Probe Measurement: Understand that infrared (non-contact) and K-Type probe (contact) measurements are distinct. Infrared measures surface temperature, while the probe measures internal or contact temperature. For example, when measuring water temperature, infrared will show the surface temperature, which can be affected by ambient air, while the probe measures the temperature beneath the surface. Always choose the appropriate method for your specific measurement need to avoid bias.
- Optimal Distance: Utilize the 12:1 Distance Spot Ratio effectively. For smaller targets, get closer to ensure the measurement spot covers only the desired area. For larger targets or when measuring from a distance, ensure the target completely fills the measurement spot.
- Emissivity Settings: For critical measurements, especially on reflective or non-organic surfaces, research the emissivity value of the material and adjust the thermometer accordingly for improved accuracy.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the contact information provided at the point of purchase or on the manufacturer's official website. Keep your purchase receipt as proof of purchase.