1. Introduction
This manual provides essential information for the safe and efficient operation of your EASUN Power Hybrid Solar Inverter. This series of inverters integrates a solar charge controller, inverter, and AC charger into one system to offer uninterruptible power support. It features a pure sine wave output, MPPT solar charge controller, and is designed for off-grid applications. Certain models also support parallel operation and WiFi monitoring.
Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.
2. Safety Information
Always observe the following safety precautions to reduce the risk of injury or damage to the inverter and connected equipment.
- High Voltage Warning: This device operates at high voltages (above 50Vac or 75Vdc). Only qualified personnel should perform installation and maintenance.
- Battery Disconnection: Do NOT disconnect the battery when the unit is in operation.
- Mounting Surface: The inverter is suitable for mounting on concrete or other non-combustible surfaces ONLY.
- Flammable Materials: Do not mount the inverter on flammable construction materials.
- Ventilation: Ensure adequate ventilation around the inverter. Do not block air vents.
- Environmental Conditions: Operate the inverter within the specified ambient temperature range (0°C to 55°C).
- Wiring: All wiring must comply with local and national electrical codes.
3. Product Overview
The EASUN Power Hybrid Solar Inverter is a versatile unit designed to manage power from solar panels, batteries, and the utility grid to supply power to your loads.
3.1. Key Features
- Lithium Battery activation function by PV or Utility.
- Compatible with LiFePO4 batteries via RS485 communication.
- Pure sine wave output.
- Wide PV input voltage range (60Vdc-500Vdc).
- Built-in MPPT 100A/120A solar charge controller.
- Capable of working without a battery (for certain configurations).
- Detachable dustcover for harsh environments.
- Optional WiFi monitoring for remote system management.
- Supports multiple output priorities: UTL (Utility first), SOL (Solar first), SBU (Solar-Battery-Utility), SUB (Solar-Utility-Battery).
- EQ function to optimize battery performance and extend lifespan.
- SMS-6.5KP-WIFI model supports parallel function (1-9 units).
3.2. Inverter Components


- AC Input
- Main Output
- Second Output
- Battery Input
- PV Input
- WIFI port
- BMS Communication port
- Power On/Off Switch
- AC Input Breaker
3.3. LCD Display and Indicators

LED Indicators:
| LED Indicator | Color | Messages |
|---|---|---|
| AC / INV | Green | Solid On: Output is powered by utility in Line mode. Flashing: Output is powered by battery or PV in battery mode. |
| CHG | Green | Solid On: Battery is fully charged. Flashing: Battery is charging. |
| FAULT | Red | Solid On: Fault occurs in the inverter. Flashing: Warning condition occurs in the inverter. |
Function Keys:
| Function Key | Description |
|---|---|
| ESC | To exit setting mode |
| UP | To go to previous selection |
| DOWN | To go to next selection |
| ENTER | To confirm the selection in setting mode or enter setting mode |
4. Installation and Setup
4.1. Mounting the Unit
Consider the following points before selecting where to install your inverter:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level to allow the LCD display to be read at all times.
- The ambient temperature should be between 0°C and 55°C to ensure optimal operation.
- The recommended installation position is to be adhered to the wall vertically.
- Be sure to keep other objects and surfaces as shown in the diagram to guarantee sufficient heat dissipation and to have enough space for removing wires.

4.2. System Connection Diagram
The inverter can be connected to various power sources and loads as shown in the system diagram below.

4.3. PV Connection
When selecting proper PV modules, please consider the following parameters:
- Open circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
- Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.

4.4. Battery Connection
For the 6.5KW model, a 48VDC battery system is supported. Ensure batteries are connected in series to achieve the required voltage.

4.5. Parallel Operation (SMS-6.5KP-WIFI Model Only)
The SMS-6.5KP-WIFI model supports parallel operation of 1-9 units to increase total power output. Refer to the diagram for proper parallel wiring.

5. Operation
5.1. Powering On/Off
Use the Power On/Off Switch (labeled 8 in Figure 3.2) to turn the inverter on or off. Ensure all connections are secure before powering on.
5.2. LCD Display Information
The LCD provides real-time information about the inverter's status, including input sources, output, battery status, and operational modes. Refer to the table below for icon descriptions.

5.3. Setting Output Priority
The inverter supports multiple output priority settings, which can be configured via the LCD display and function keys:
- UTL (Utility first): Prioritizes utility power to supply loads.
- SOL (Solar first): Prioritizes solar power to supply loads.
- SBU (Solar-Battery-Utility): Prioritizes solar, then battery, then utility.
- SUB (Solar-Utility-Battery): Prioritizes solar, then utility, then battery.
Use the UP/DOWN keys to navigate through settings and ENTER to confirm your selection.
5.4. WiFi Monitoring
For models with optional WiFi monitoring, connect the WiFi module to the designated port (labeled 6 in Figure 3.2). Follow the instructions provided with the WiFi module for app setup and remote monitoring.
6. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Keep the inverter's exterior clean. Use a dry cloth to wipe dust. Ensure the detachable dustcover is clean and properly installed, especially in harsh environments.
- Ventilation: Periodically check that the ventilation openings are clear of dust and debris to prevent overheating.
- Connections: Regularly inspect all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion. Tighten any loose connections.
- Battery Health: Monitor battery voltage and performance. Utilize the EQ function to optimize battery performance and extend its lifespan.
- Firmware Updates: Check the manufacturer's website for any available firmware updates for your model.
7. Troubleshooting
If you encounter issues with your inverter, refer to the LED indicators and LCD display for fault codes or warning messages.
- Red FAULT LED (Solid On): Indicates a fault in the inverter. Check the LCD for a specific fault code.
- Red FAULT LED (Flashing): Indicates a warning condition. Check the LCD for a specific warning code.
- No Power Output: Check AC input breaker, battery connections, and PV input. Ensure the inverter is powered on.
- Battery Not Charging: Verify PV array connection and voltage. Check charge current settings.
- Inverter Overheating: Ensure proper ventilation and ambient temperature. Clean dust from vents.
For persistent issues, consult the detailed troubleshooting section in the full product manual (if available) or contact customer support.
8. Specifications
Below is a comprehensive table detailing the specifications for various EASUN Power Hybrid Solar Inverter models.

Key Specifications Summary:
| Feature | SMT-2KW-12V-WIFI | SMT-4KW-24V-WIFI | SMT-6.2KW-48V-WIFI | SMS-6.5KP-48V-WIFI |
|---|---|---|---|---|
| Capacity | 2KVA/1.6KW | 4KVA/3.6KW | 6.2KVA/6.2KW | 6.5KVA/6.5KW |
| Battery Voltage | 12VDC | 24VDC | 48VDC | 48VDC |
| Max. PV Array Power | 2000W | 5000W | 8500W | 9000W |
| PV Array MPPT Voltage Range | 30VDC ~ 500VDC | 60VDC ~ 500VDC | 60VDC ~ 500VDC | 60VDC ~ 450VDC |
| Max. Charge Current | 100A | 120A | 120A | 120A |
| Output Waveform | Pure Sine wave | Pure Sine wave | Pure Sine wave | Pure Sine wave |
| Parallel Function | NO | NO | NO | YES, 1-9pcs |
| Communication Interface | RS232 / RS485 / Wifi | RS232 / RS485 / Wifi | RS232 / RS485 / Wifi | RS232 / RS485 / Wifi |
9. User Tips
- Grid-Tie vs. Off-Grid: This inverter is designed for off-grid applications. It does not send power back to the utility grid even when batteries are full. Ensure your system design aligns with this functionality.
- Battery Compatibility: While compatible with LiFePO4 batteries via RS485, always verify the specific battery model and its communication protocol for seamless integration.
- Monitoring: Utilize the optional WiFi monitoring feature to keep track of your system's performance and health remotely. This can help in early detection of potential issues.
- PV Module Sizing: Carefully calculate your PV array size to match the inverter's maximum PV input power and voltage range for optimal energy harvesting.
10. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the EASUN POWER EU Direct Store directly. Keep your purchase receipt as proof of purchase.