1. Introduction
1.1. BMS Overview
The JIKONG Lithium battery intelligent protection board is a management system tailored for large capacity series lithium battery packs. It features voltage acquisition, high current active balancing, overcharge/over-temperature protection, coulomb meter, Bluetooth communication, and host computer monitoring functions. It is applicable to lithium iron phosphate (LiFePo4) and ternary lithium battery types.
The protection board utilizes energy transfer active balancing technology with independent intellectual property rights, achieving a maximum continuous 1A/2A balance current. This high current active equalization technology ensures battery consistency, improves battery range, and delays battery aging.
A mobile APP (Android and iOS) is available for connecting to the protection board via Bluetooth to check battery status, modify parameters, and control charge/discharge switches. The compact design, simple operation, and comprehensive functions make it suitable for high-power energy storage, base station backup power supply, solar power stations, and other battery PACK products.
1.2. Functional Characteristics
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- Supports PC operations
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 communication
- Support CAN communication
- Support heating function
- Alarm dry contact function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function
2. Package Contents
Upon opening the package, please verify that all items listed below are present and in good condition:

| No. | Item | Description |
|---|---|---|
| 1 | Packing BOX | |
| 2 | BMS | |
| 3 | Interface board | |
| 4 | Adapter | |
| 5 | RJ45 Network cable | 400mm |
| 6 | Switch | 500mm |
| 7 | Heating Adapter cable x1 | 170mm |
| 8 | Cells total B+Cable x1 | 500mm |
| 9 | Sampling line A | 900mm |
| 10 | Sampling line A | 900mm |
| 11 | Sampling line B | 900mm |
| 12 | Sampling line C | 900mm |
| 13 | Adapter cable A | 300mm |
| 14 | Adapter cable B | 300mm |
| 15 | Adapter cable C | 300mm |
| 16 | 4.3LCD-TTL-P |
3. Installation and Setup
3.1. Product Appearance and Dimensions
The JIKONG JK-PB1/2A16S-10/15/20P series protection board measures 300mm × 100mm × 24mm.


3.2. Wiring Method
The JK-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack.

3.3. Interface Definition
The protection board comes with a factory-standard interface board for user convenience, featuring LED indicators, a reset switch, DIP switches, dry contacts, and communication functions.

Key Interfaces:
- P1, P2, P3 Ports: Connect to the interface board.
- UART Port: For communication.
- Display or Switch Port: For connecting an optional display or external switch.
- Heat Function Port: For connecting heating elements.
- Sampling Line Ports (1-4): For monitoring individual cell voltages.
- RS485-1 Interface: Used for communication with inverters and other settings.
- RS485-2 Interface: Used for connecting battery packs in parallel and communicating with a host computer.
- CAN Interface: For CAN communication with inverters.
- RS232 Interface: For serial communication.
- Dry Interface: For controlling external devices like alarms or fans.
- Dial Switch: Used to set the communication address for parallel operation (0-15).
3.4. Device Activation
Before powering on the protection board, ensure that the balance cable is properly connected and that P- and B- are correctly connected. Confirm that the protection board is securely fixed to the battery core. Incorrect connections can lead to malfunctions or damage.
The protection board does not have a power-on control switch. It is designed for charging activation mode (charger voltage 2V higher than battery voltage). After battery assembly, connect a charger to activate the board. Key activation and display activation are also supported; users with a display screen and button can activate by inserting the cable and pressing the button.
4. Operation
4.1. APP and PC Software Monitoring
The JIKONG BMS can be monitored and configured via a mobile APP (Android/iOS) or PC software. These interfaces allow users to view real-time battery data, adjust protection parameters, and control various functions.


4.2. Active Equalization
The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring battery consistency. Users can set the balance trigger voltage difference (mV) via the APP. When the difference exceeds the set value, equalization automatically activates. The default balance current is 1A/2A, adjustable based on battery capacity (recommended not to exceed 0.2C of battery capacity). The equalization function can be turned off in the APP if not needed.

4.3. Heating Function
The BMS includes a heating function to prevent charging/discharging issues in low-temperature conditions. It uses a resistance heater or heating film to warm the battery. The designed heating current is 10A. This function can be controlled via the APP. It is recommended to install a temperature control switch (45°C to 65°C normally closed type) in the heating circuit as a secondary protection.4.4. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects over-temperature, overcharge, or over-discharge, the alarm interface can switch the dry contact status. Users can select two trigger conditions and configure them via the APP.
4.5. Protection Features
- Charge Overvoltage Protection: Prevents overcharging by shutting off charging when any cell voltage exceeds the set limit. Charging resumes when all cell voltages drop below the recovery voltage.
- Discharge Undervoltage Protection: Prevents over-discharging by shutting off discharge when any cell voltage drops below the set limit. Discharge resumes when all cell voltages rise above the recovery voltage. An automatic shutdown voltage is also configurable.
- Charge Overcurrent Protection: Triggers if charging current exceeds the set continuous charging current for a specified delay. Charging is stopped and resumes after a release time.
- Discharge Overcurrent Protection: Triggers if discharging current exceeds the set continuous discharging current for a specified delay. Discharging is stopped and resumes after a release time.
- Overtemperature Protection: Shuts down charging/discharging if battery temperature exceeds set limits. Resumes when temperature returns to safe levels.
- Low Temperature Protection: Shuts down charging if battery temperature falls below set limits. Resumes when temperature rises above recovery levels. Heating function is recommended for extremely cold areas.
- Short Circuit Protection: Protects against short circuits. Users can set delay (µs) and recovery time (S) via the APP. If a short circuit occurs during initial charging or loading, increasing the delay may resolve it.
4.6. Emergency Switch
The emergency switch function, activated via the APP, allows the protection board to continue charge/discharge for 30 minutes even if issues like over-temperature, over-discharge, over-charge, or cell imbalance occur. This provides a temporary operational window, preventing immediate system shutdown.4.7. Intelligent Sleep
The intelligent sleep function, configurable via the APP, reduces BMS power consumption by shutting down when the board is in standby (charge/discharge current less than 1A for 26 hours). It can be reactivated by pressing a button or connecting a charger.4.8. Communication Function
The BMS supports CAN and RS485 communication. CAN communication defaults to 250K baud rate. RS485-1 is used for inverter communication, with protocols selectable via the APP. RS485-2 (two parallel ports) connects multiple battery packs to a host computer for monitoring, with a default baud rate of 115200. Communication addresses (0-15) are set via DIP switches.


4.9. Charge Current Limiting Function
The BMS includes a charge current limiting function. When the battery is overcharged, this function activates, limiting the charging current to approximately 10A to protect the battery. Users can set continuous charging current, overcurrent delay, and release time via the APP.
5. Maintenance
To ensure optimal performance and longevity of your JIKONG BMS, regular maintenance is recommended:
- Regular Inspections: Periodically check all wiring connections for tightness and signs of wear or corrosion.
- Software Updates: Keep the mobile APP and PC software updated to the latest versions to benefit from new features and bug fixes.
- Environmental Conditions: Ensure the BMS operates within its specified temperature range. Avoid exposure to excessive moisture or extreme temperatures.
- Cleaning: Gently clean the exterior of the BMS and interface board with a dry, soft cloth. Do not use liquid cleaners or solvents.
- Parameter Review: Occasionally review the BMS parameters via the APP or PC software to ensure they are still appropriate for your battery configuration and usage patterns.
6. Troubleshooting
If you encounter issues with your JIKONG BMS, consider the following troubleshooting steps:
- No Power/Activation Issue: Ensure all connections (balance cables, P-, B-) are correct and secure. If using charging activation, confirm the charger voltage is at least 2V higher than the battery voltage.
- Communication Problems: Check Bluetooth connection for the APP or RS485/CAN connections for PC/inverter. Verify DIP switch settings for parallel communication addresses.
- Protection Triggered: If a protection (overvoltage, undervoltage, overcurrent, overtemperature, short circuit) is triggered, check the battery status and environmental conditions. Review and adjust the corresponding parameters in the APP/PC software.
- Cell Imbalance: If cell voltages are consistently imbalanced, ensure the active equalization function is enabled and parameters are correctly set.
- System Reset: If the BMS becomes unresponsive, try pressing the reset button on the interface board.
- Refer to Manual: For detailed error codes or specific issues, consult the comprehensive PDF manual.
7. Specifications
The following table outlines the key product parameters for the JIKONG BMS JK-PB2A16S20P model:

| Parameter | Value | Unit |
|---|---|---|
| Supply Voltage | 20-70 | V |
| Standby Power Consumption | 12 | mW |
| Operating Power Consumption | 1100 | mW |
| Operating Temperature | -30 to 70 | °C |
| Max. Number of Collection Strings | 16 | S |
| Max. Balancing Current | 2 | A |
| Max. Charging Current (20P) | 200 | A |
| Max. Discharge Current (20P) | 200 | A |
| Max. Instantaneous Current (20P) | 400 | A |
| Max. Internal Loop Resistance (20P) | 0.35 | mΩ |
| Protection Board Size | 300*100*24 | mm |
| Finished Weight | 1000 | g |
8. User Tips
To maximize the performance and lifespan of your JIKONG BMS and battery system, consider these tips:
- Initial Setup Verification: Double-check all wiring, especially balance leads and main power connections, before applying power. A common mistake is incorrect balance lead order.
- Parameter Customization: While default parameters are provided, fine-tuning settings like overvoltage/undervoltage protection and equalization thresholds via the APP or PC software can optimize performance for your specific battery chemistry and application.
- Monitor Regularly: Utilize the mobile APP or PC software to regularly monitor battery health, individual cell voltages, and temperature. This helps in early detection of potential issues.
- Parallel System Configuration: When using multiple BMS units in parallel, ensure each unit has a unique address set via the DIP switches to avoid communication conflicts.
- Heating Function in Cold Climates: If operating in cold environments, ensure the heating function is properly configured and utilized to prevent battery damage and maintain charging/discharging efficiency.
- Consult PDF Manual: For any complex configurations or detailed technical information, always refer to the comprehensive PDF user manual.
9. Warranty and Support
For detailed warranty information and technical support, please refer to the official documentation provided by JIKONG. A comprehensive user manual in PDF format is available for download and contains in-depth information on all aspects of the BMS.
Reference: JIKONG BMS User Manual (PDF)