1. Introduction
The Hantek 2000 Series Handheld Oscilloscope is a compact and lightweight 3-in-1 multifunction tester designed for engineers and enthusiasts. It integrates an oscilloscope, a signal source (waveform generator), and a digital multimeter into a single portable device. This manual provides detailed instructions for the safe and efficient operation of your Hantek 2000 Series device.
Video: Hantek Handheld Oscilloscope 2000 Series Product Overview and Unboxing.
2. Package Contents
Verify that all items listed below are included in your package. Contents may vary slightly depending on the specific model (2C42, 2C72, 2D42, 2D72).
- 1x Hantek Handheld Oscilloscope Unit
- 1x Passive Oscilloscope Probe (Models 2C42, 2C72) or 2x Passive Oscilloscope Probes (Models 2D42, 2D72)
- 1x Crocodile Clip Test Line (Models 2C42, 2C72) or 2x Crocodile Clip Test Lines (Models 2D42, 2D72)
- 1x Power Adapter (Charging Plug)
- 1x Multimeter Leads
- 1x USB Type-C Charging and Data Cable
- 1x Carrying Case
- 1x User's Guide
- 1x Certification Card

Image: Hantek Handheld Oscilloscope and included accessories.
3. Setup
3.1 Battery Installation
The device uses two 18650 replaceable lithium batteries. Ensure batteries are correctly inserted according to polarity markings.

Image: Battery compartment with 18650 batteries.
3.2 Charging the Device
Connect the provided Type-C charging cable to the device's USB port and the power adapter. The device supports 5V/2A charging. You can use a standard mobile phone charger with a Type-C cable.

Image: Device charging via USB-C.
3.3 Connecting Probes and Leads
The device features standard BNC connectors for oscilloscope probes (CH1, CH2, Gen Out) and banana plug inputs for multimeter leads (A, mA, COM, V/Ω/C/+).

Image: Device ports for oscilloscope and multimeter connections.
4. Operating Instructions
4.1 General Operation
The device features a minimalist keyboard design for ease of use. The suspending stand allows for multi-angle adjustment.

Image: Device with kickstand for convenient viewing.
4.2 Oscilloscope Function
Press the 'Scope' button to enter oscilloscope mode. The device features a high-definition color LCD screen for clear waveform display. Use the navigation buttons to adjust settings like vertical resolution, time base, and trigger.

Image: Oscilloscope display elements including trigger status, main time base window, trigger level, battery level, window displays waveform, channel marker, channel information, trigger time, and time base.
The 'Auto' button provides an automatic measuring function, identifying the type of waveform (sine or square wave) and adjusting settings accordingly. Cursor measurement functions support manual time and voltage measurements.

Image: Oscilloscope control buttons including Scope, DMM, AWG, Menu, Trig, Channel, Time, Enter, Auto, Power Key, Run/Stop.
4.3 Multimeter Function
Press the 'DMM' button to switch to digital multimeter mode. This function allows measurement of AC/DC voltage, current, resistance, capacitance, diode, and on-off tests. It offers high sensitivity and accuracy with a clear display.

Image: Device displaying multimeter function with DC voltage reading.
4.4 Waveform Generator Function (2D42, 2D72 models only)
For models 2D42 and 2D72, press the 'AWG' button to access the waveform generator. It can output sine, square, triangle, and trapezoidal waveforms. The sine wave output can go up to 25MHz.

Image: Waveform generator output settings.
The Gen Out terminal of the oscilloscope without signal generator function always outputs a 2V @ 1KHz square wave, which can be used for probe calibration.
4.5 Menu and Language Settings
Press the 'Menu' button to access settings. You can switch the interface language between Chinese and English. Other settings include sound for button presses, backlight brightness, and backlight duration.
5. Firmware Update
It is recommended to update the device firmware to ensure optimal performance and resolve potential bugs. Firmware and programming tools are available on the manufacturer's website.
5.1 Entering DFU Mode
To update the firmware, the device must be in DFU (Device Firmware Upgrade) mode. While the device is powered off, hold down the 'F1' button and then power on the device. Connect the device to your computer via the USB Type-C cable.
5.2 Using the DFU Tool
Download the DFUSe Demo tool and the latest firmware file (.dfu) from the Hantek website. Open the DFUSe Demo tool, select the device in DFU mode, choose the firmware file, and click 'Upgrade'.

Image: Screenshot of the DFUSe Demo tool during firmware update.
5.3 Updating FPGA Firmware
For FPGA firmware updates, connect the powered-on device to your computer. Open the Hantek2000 PC software. Press the key combination Alt+Ctrl+Shift+F to open the FPGA Update dialog. Select the FPGA firmware file (.bin) and click 'Update'. Restart the device after the update is complete.
6. Maintenance
- Keep the device clean and dry. Avoid exposure to dust, moisture, and extreme temperatures.
- Use a soft, damp cloth to clean the exterior. Do not use abrasive cleaners or solvents.
- Perform self-calibration periodically or if you notice any measurement discrepancies.
- Store the device in its carrying case when not in use to protect it from physical damage.

Image: Hantek carrying case for protection and portability.
7. Troubleshooting
- Incorrect Readings/Glitches: Ensure the device firmware is up to date. Refer to Section 5 for firmware update instructions.
- Probe Attenuator Issues: The attenuator switch on the probe (1X/10X) can be easily accidentally switched. Always verify its position before taking measurements.
- Device Not Powering On: Check battery charge level. Ensure batteries are correctly installed.
- Display Unclear: Adjust backlight settings in the menu.
8. Specifications
8.1 General Specifications
| Feature | Specification |
|---|---|
| Display Type | 2.8 inch 64K color TFT |
| Display Resolution | 320 horizontal by 240 vertical pixels |
| Display Size | 3.0 - 4.9 Inches |
| Power Supply | 100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A |
| Power Consumption | <2.5W |
| Battery | 2600mA*2 (18650 replaceable lithium battery) |
| Operating Temperature | 0~50 °C (32~122 °F) |
| Storage Temperature | -40~+71 °C (-40~159.8 °F) |
| Humidity | ≤+104°F (≤+40°C): ≤90% RH; ≤122°F (+41°C ~50°C): ≤60% RH |
| Cooling Method | Convection |
| Altitude | Operating and Nonoperating: 3,000m (10,000 feet) |
| Random Vibration | 0.310RMS from 5Hz to 500Hz, 10 minutes on each axis |
| Mechanical Shock | Nonoperating: 2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis; Operating: 50g, 11ms, half sine |
| Dimension (L x W x H) | 199 x 98 x 40mm |
| Weight | 624g |
| Certification | CE |
8.2 Oscilloscope Specifications
| Feature | Hantek2D72 | Hantek2D42 | Hantek2C72 | Hantek2C42 |
|---|---|---|---|---|
| Channel | 2CH+DMM+AWG | 2CH+DMM+AWG | 2CH+DMM | 2CH+DMM |
| Bandwidth | 70MHz | 40MHz | 70MHz | 40MHz |
| Sample Rate Range | 250MSa/s (Single-channel), 125MSa/s (Dual-channel) | |||
| Waveform Interpolation | (sin x)/x | |||
| Record Length | Max. 6K for single-channel; 3K samples per dual-channel | |||
| SEC/DIV Range | 5ns/div~500s/div 1, 2, 5 sequence | |||
| Vertical Resolution | 8-bit resolution, each channel sampled simultaneously | |||
| VOLTS/DIV Range | 10mV/div~10V/div at input BNC | |||
| Bandwidth Limit | 20MHz, typical | |||
| Low Frequency Response (-3dB) | ≤10Hz at BNC | |||
| Rise Time at BNC | ≤5ns | |||
| DC Gain Accuracy | ±3% for Normal or Average acquisition mode, 10V/div to 10mV/div | |||
| Acquisition Modes | Normal | |||
| Trigger Type | Edge | |||
| Trigger Mode | Auto, Normal, Single | |||
| Trigger Level | ±4 divisions from center of screen | |||
| Input | CH1/CH2 | |||
| Coupling | DC, AC or GND | |||
| Input Impedance | 25pF±3 pF, 1MΩ±2% | |||
| Probe Attenuation | 1X, 10X | |||
| Supported Probe Attenuation Factors | 1X, 10X, 100X, 1000X | |||
| Maximum Input Voltage | 150VRMS | |||
8.3 Multimeter Specifications
| Measurement Term | Range | Accuracy | Resolution |
|---|---|---|---|
| Maximum Resolution | 4000 Counts | ||
| DMM Testing Modes | Voltage, Current, Resistance, Capacitance, Diode & On-Off | ||
| Maximum Input Voltage | AC: 600V, DC: 800V | ||
| Maximum Input Current | AC: 10A, DC: 10A | ||
| Input Impedance | 10MΩ | ||
| DC Voltage | 400.00mV | ±(0.8%+5) | 100uV |
| 4.000V | ±(0.8%+5) | 1mV | |
| 40.00V | ±(0.8%+5) | 10mV | |
| 400.0V | ±(0.8%+5) | 100mV | |
| 600.0V | ±(1%+2) | 1V | |
| Overload protection: 400mV: 250V, other: 600Vrms. | |||
| AC Voltage | 4.000V | ±(1.2%+5) | 1mV |
| 40.00V | ±(1.2%+5) | 10mV | |
| 400.0V | ±(1.2%+5) | 100mV | |
| 600.0V | ±(1.5%+5) | 1V | |
| Frequency: 40Hz~400Hz; Frequency of 400V and 600V: 40Hz~100Hz | |||
| DC Current | 40.00mA | ±(1%+2) | 10uA |
| 200.0mA | ±(1.5%+2) | 100uA | |
| 4.000A | ±(1.8%+2) | 1mA | |
| 10.00A | ±(3%+2) | 10mA | |
| Overload protection: self restoring fuse: 200mA/250V, 4A and 10A range no fuse. | |||
| Resistance | 400.0Ω | ±(1%+3) | 0.1Ω |
| 4.000KΩ | ±(1%+3) | 1Ω | |
| 40.00KΩ | ±(1%+3) | 10Ω | |
| 400.0KΩ | ±(1%+3) | 100Ω | |
| 4.000MΩ | ±(1.5%+3) | 1KΩ | |
| 40.00MΩ | ±(1.5%+3) | 10KΩ | |
| Overload protection: 220Vrms | |||
| Capacitance | 40.00nF | ±(3%+5) | 10pF |
| 400.0nF | ±(3%+5) | 100pF | |
| 4.000uF | ±(3%+5) | 1nF | |
| 40.00uF | ±(3%+5) | 10nF | |
| 100.0uF | ±(3%+5) | 100nF | |
| Overload protection: 220Vrms | |||
| Diode | 0V~1.0V | ||
| On-Off | <50Ω | ||
8.4 Waveform Generator Specifications
| Feature | Specification |
|---|---|
| Waveform Frequencies (Sine) | 1Hz~25MHz |
| Waveform Frequencies (Square) | 1Hz~10MHz |
| Waveform Frequencies (Ramp) | 1Hz~1MHz |
| Waveform Frequencies (EXP) | 1Hz~5MHz |
| Sampling | 250MSa/s |
| Amplitude | 2.5Vpp(50Ω) / 5Vpp(High impedance) |
| Frequency Resolution | 0.10% |
| Channel | 1CH waveform output |
| Waveform Depth | 512Sa |
9. User Tips
- Always ensure the device's firmware is updated to the latest version from the official Hantek website to benefit from bug fixes and performance improvements.
- When using oscilloscope probes, be mindful of the 1X/10X attenuator switch. It can be easily moved, leading to incorrect readings if not set as expected.
- The Type-C port is versatile; it handles both charging and data transfer to a PC.
- Utilize the 'Auto' function in oscilloscope mode for quick and convenient waveform setup, especially for new users.
- The device features a self-calibration function to maintain accuracy over time. Consult the full manual for detailed calibration steps.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the official Hantek website or contact your authorized dealer. Keep your purchase receipt as proof of purchase.