PowMr POW-M60-ULTRA

Contents

PowMr EU MPPT 60A Solar Charge Controller

Model: POW-M60-ULTRA

1. Product Introduction

Welcome to the POW-M60 series solar controller. This controller represents advanced innovation in the field of solar technology and is designed to provide exceptional performance and reliability for your solar energy system. The controller is equipped with advanced CNC technology, an LCD display, automated operation, and a Maximum Power Point Tracking (MPPT) battery charging mode. Combined with advanced control technology, it significantly extends the lifespan of your batteries.

The POW-M60 series solar controller is designed to meet the diverse needs of various solar energy systems, whether in standalone systems or other application scenarios. It automatically controls the charging and discharging processes. By optimizing the controller's battery charging and discharging processes, it not only prolongs the battery's lifespan but also enhances the overall system's performance. The controller features self-diagnostic functions and electronic protection, effectively preventing damage to the controller or batteries during installation errors or system faults, ensuring system reliability and stability.

Our POW-M60 series solar controllers are suitable for a wide range of solar energy applications. We offer a user-friendly custom open-program configuration interface, making the configuration process of solar energy systems quicker and smoother. It also provides more possibilities for expanding solar energy systems. Whether you are setting up a small-scale residential standalone solar system or expanding your solar energy project, the POW-M60 series solar controller will be an indispensable partner.

By choosing the POW-M60 series solar controller, you will gain an efficient, sustainable, and secure energy management solution that provides strong support for future energy needs. We are committed to advancing solar technology and delivering outstanding products and services to you.

2. Important Safety Instructions

WARNING: Carefully read and adhere to all safety instructions.

  • Before installing and operating the controller, please read the user manual thoroughly and keep it for future reference.
  • The installation or operation of the controller should only be performed by individuals who have received proper training and supervision.
  • Do not charge non-rechargeable batteries. Do not charge lithium batteries when the temperature is below 0°C. Charging frozen batteries is prohibited.
  • Ensure that the equipment is properly configured for the type of battery connected to it.

Controller Installation and Operation Safety

  • This controller product does not have user-serviceable components; do not disassemble or attempt to repair the controller yourself.
  • Install the controller in a well-ventilated environment with adequate clearance around it.
  • Install the controller on non-combustible walls and ensure there are no flammable materials nearby; it is normal for the controller to generate heat during operation.
  • Place the controller in an environment that is protected from direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • Do not place any objects on top of the controller.

Battery Installation and Charging Safety

  • Install and charge batteries in well-ventilated or exhaust-ventilated environments.
  • Ensure there are no open flames in the vicinity of the batteries, as batteries emit explosive gases.
  • Battery acid is corrosive; if battery acid comes into contact with the skin, rinse immediately with clean water.

3. Features

  • Integrated Charging Presets: Adaptive charging logic suitable for most battery types (flooded lead-acid, gel-sealed lead-acid, lithium). Specific charging parameters are detailed in Section 3.7.
  • Versatile Application: Compatible with 12V/24V/36V/48V system voltages.
  • Multi-Stage Charging Algorithm: Optimizes each charging cycle with bulk, absorption, and float stages to maintain battery capacity and extend lifespan.
  • Maximum Power Point Tracking (MPPT) Technology: Tracks the maximum power point voltage (Vmp) of the array to ensure maximum power collection throughout the day.
  • High-Efficiency Charging: Innovative MPPT technology with tracking efficiency up to 99.9% and peak conversion efficiency up to 98.1%, reducing power consumption and heat generation.
  • Customizable Charging Current Limit: Configurable charging current limit from 2 to 60A to prevent excessive charging rates and extend battery lifespan.
  • Supports Up to 12 Units in Parallel: Allows easy expansion of solar panel configuration and energy storage capacity. Refer to Section 7 for parallel operation guidelines.
  • Adaptive Boost Charging: Monitors battery response to determine boost stage duration, ensuring full charge without overcharging.
  • Durable and Secure: Features photovoltaic input overcurrent, photovoltaic array short circuit, reversed photovoltaic polarity, overvoltage protection for batteries, overdischarge protection for batteries, and over-temperature protection.
  • External Temperature Probe Configuration: Precisely monitors battery temperature. Charging stops if battery temperature exceeds 65°C and resumes below 55°C.
  • Forced Air Cooling & Heat Dissipation Backplate: Internal cooling fan and external heat dissipation plate enhance efficiency.
  • One-Click Factory Reset: Long-press the "SET" button to revert all configurable settings to factory defaults.
  • Lithium Battery Activation: Compatible with lithium batteries. The controller activates protected lithium batteries using solar panel energy, within protection voltage and current limits.

4. Product Appearance

PowMr MPPT Solar Charge Controller front view
Front view of the PowMr MPPT Solar Charge Controller.
PowMr MPPT Solar Charge Controller top view with buttons and screen
Top view of the controller showing the LCD display and function keys.
PowMr MPPT Solar Charge Controller bottom view with heatsink
Bottom view of the controller highlighting the heatsink for efficient heat dissipation.

Component Identification

No.Component
1LCD display
2Function key
3PV input port
4Battery port
5Load port
6Temperature probe port
7Parallel communication port
8Heat sink

5. Setup (Installation and Wiring)

5.1 Unpacking and Inspection

Before unpacking, inspect the packaging for any signs of damage. After unpacking, check the contents to ensure nothing is damaged or missing. Inside the package, you will find the following items:

  • Controller
  • User Manual
  • Installation Guide card
  • Installation screws
  • Parallel Communication Cable
  • Parallel Communication Terminal
  • External temperature sensor

5.2 Choosing the Installation Location

Before installation, several aspects should be considered to determine or provide a suitable and safe installation location:

  • Install the controller in a space with good natural ventilation/exhaust.
  • Avoid direct sunlight.
  • Ensure there is ample clearance around the controller. The minimum clearance at the top, bottom, and both sides of the controller is 75mm.
  • Install the controller on a non-combustible wall and ensure there are no flammable materials nearby; an increase in temperature during controller operation is a normal occurrence.
  • Install the controller in an environment that avoids direct sunlight, rain, humidity, and dust, and keep it away from any flammable liquids or gases. The controller is for indoor use only.
  • Do not install or operate the controller on top of, directly above, or in an enclosed space above batteries, as batteries emit explosive gases.
  • When running multiple controllers in parallel, ensure they are installed at the same horizontal height, with a minimum spacing of 75mm between controllers.

5.3 Wiring Precautions

  1. Installation and wiring work should be carried out by a certified electrician.
  2. Wiring should follow the sequence of Battery > PV Input > Load.
  3. To avoid short-circuits and polarity reversal, pay attention to connecting the positive (+) cable to the device's positive (+) terminal and the negative (-) cable to the device's negative (-) terminal.
  4. Loose and/or incomplete connections can lead to cable or terminal overheating. Therefore, tighten all cables to minimize transition resistance, using cable sizes appropriate for the specific circuit's current rating.
  5. Do not connect the inverter to the load terminal of the controller, as doing so may result in irreversible damage to the equipment. If it is necessary to connect the inverter, please follow the battery connection steps outlined in Section 2.4, as indicated in the wiring diagram.

5.4 Installation and Wiring Guidelines

Please refer to the following steps to complete the installation and wiring of the controller. For parallel connection wiring, please refer to Chapter 7.

Video: Introduction to the PowMr M60 Solar Controller and basic wiring steps for a 12V/24V/36V/48V DC system.
  1. Step 1. Install the controller: Install the controller vertically with its ports facing downward, securing it to the wall through the four mounting holes using screws. For ease of installation, it is recommended to use two upper screws for initial "hanging" of the device, followed by the addition of two lower screws, and then fully tighten all four screws.
  2. Step 2. Battery Wiring: Connect the battery to the controller using cables.
Battery wiring diagram for PowMr MPPT Solar Charge Controller
Diagram showing battery connection to the MPPT Solar Charge Controller.

Attention:

  • Do not connect the inverter to the load terminal of the controller; otherwise, it may cause irreversible damage to the equipment. If it is necessary to connect the inverter, please refer to the diagram below.
Solar Connect Diagram showing PV, Battery, Load, and Inverter connections
Solar Connect Diagram illustrating connections for PV, Battery, Load, and Inverter.

NOTE on DC Battery Connections:

  • All wiring work must be carried out by professionals.
  • For safe operation and proper application, circuit breakers of the appropriate specifications must be installed on the cables connected to the controller, and ensure that the connections are tight.
  • Ensure that all circuit breakers are in the off position before completing all wiring.
  • Connect the positive cable terminal to the positive terminal port, and the negative cable terminal to the negative terminal port.
  • The above notes also apply to the PV ports and DC output ports.
  1. Step 3. PV Wiring: Connect the photovoltaic array to the controller using cables.
Solar Panel Specifications and PV wiring diagram
Solar Panel Specifications and PV wiring diagram for the controller.
  1. Step 4. DC Output Wiring: Connect the load to the controller using cables.
  2. Step 5. Temperature Probe Connection: Connect the temperature probe wire to the controller and securely fix the probe end to the battery using insulation tape.
  3. Step 6. Pre-Startup Check: Refer to the wiring diagram. If all connections are accurate, and all wiring is securely connected, close the circuit breakers in the order of Battery, PV Input, and Load terminals.

WARNING: Risk of Electric Shock!

  • Before wiring, ensure that all power sources are turned off and follow the relevant inspection and operation procedures.

6. Operation Guide

6.1 LCD Screen Icon Display

LCD screen display of PowMr MPPT Solar Charge Controller
The LCD screen displays various system parameters and status icons.
No.Description
①Day/Night Indicator Icon: Indicates whether photovoltaic input is currently present.
②Battery Level Icon: Indicates the remaining battery capacity.
③Operation Mode/Error Code: Displays the current operation mode (see Section 3.3)/error code.
④Load Status Icon: Indicates the periodic operating status and alarm status of the load (see Section 4.2).
⑤PV Input Information: Shows the photovoltaic input voltage/power/total energy generated.
⑥Battery Information: Displays the current battery voltage/charging current/device temperature/battery calibration voltage/parallel communication code/battery type/equalization charging voltage/float charging voltage/DC undervoltage recovery voltage/DC undervoltage cutoff voltage.
⑦Load Operating Mode: Indicates the load operation mode.

6.2 Key Introduction

Function keyDescription
PV / ▲Browse Mode: Switch PV Input Parameters
BAT/▲Browse Mode: Short press to toggle battery information (move to the next option)
Long press to enter battery parameter settings
Set Mode: Increase Value
DC/▼Browse Mode: Short press to toggle battery information (return to the previous option)
Long press to enter load operation mode settings
Set Mode: Decrease Value
SET / ☀Short press: Confirm and Save Settings
Long Press: Restore Factory Settings

6.3 Operating Modes

Interface DisplayCodeDescription
WORK MODE 3.03.0Night Mode, No Charging
WORK MODE 4.04.0MPPT Mode
WORK MODE 7.07.0Boost Charging Mode (Constant Voltage Charging)
WORK MODE 8.08.0Float Charging Mode

Note:

In the event of a fault, the operation mode section will display the fault code. For details, please refer to section 4.2.

6.4 PV Parameters Overview

Press the PV / ▲ button briefly to switch the data displayed on the left side of the screen as follows:

PV parameters overview on LCD screen
Overview of PV input voltage, power, and total energy generation displayed on the LCD.

6.5 Battery Parameters Overview

In browsing mode, use the BAT/▲ and DC/▼ buttons to scroll through the battery parameters. When you reach the parameter you wish to set, press and hold the BAT/▲ button to enter the parameter setting mode. Once in the specific parameter's setting mode, adjust the values or scroll through options using the BAT/▲ and DC/▼ buttons, and press the SET / ☀ button to confirm the settings.

6.6 Battery Parameter Settings

The following are the configurable settings for battery-related parameters:

Battery Calibration Voltage

If there is a discrepancy between the battery voltage detected by the controller and the value measured with a multimeter, this setting can be used to calibrate the battery voltage. Press and hold the BAT/▲ button to enter the setting program, adjust the value using the BAT/▲ and DC/▼ buttons, and press the SET / ☀ button to save and confirm.

Communication Code for Parallel Operation

Note:

  • If parallel operation is not used, this setting does not need to be configured.
Parallel operation schematic with communication codes
Parallel Operation Schematic showing communication between multiple controllers.

After completing the parallel wiring, use this setting to define the master and slave units. The controller with the lowest communication code value will be the master. In a parallel operation, if the master fails, the system will automatically select the controller with the next highest communication code value as the new master. For example, if Master Unit 01 fails, the system will designate Unit 02 as the new master.

Assuming 6 controllers are operating in parallel, assign communication codes from 01 to 06 to each unit (each unit's communication code should be unique).

Possible ScenariosCode
010203040506
Scenario 1: Normal operationMasterSlaveSlaveSlaveSlaveSlave
Scenario 2: 01 failsFailureMasterSlaveSlaveSlaveSlave
Scenario 3: 03 failsMasterSlaveFailureSlaveSlaveSlave
Scenario 4: 01 and 02 failFailureFailureMasterSlaveSlaveSlave

Battery Type Selection

Note:

  • Before setting the battery parameter, please turn off the photovoltaic input to ensure that the battery is not in a charging state.

Please select the battery type according to the connected battery by referring to the table below.

Applicable Battery Type table
Table of applicable battery types and their corresponding display codes.

Press and hold the BAT/▲ button to enter the setting program, use the BAT/▲ and DC/▼ buttons to select the battery type, and press the SET / ☀ button to save and confirm. If "User Defined" is selected, you can set the following battery parameters.

Custom Charging Parameters

  • If "USE" is selected for the battery type, the following 6 charging parameters can be manually set.
  • If "USE" is not selected, manual setting of charging parameters is not required. The controller will charge according to the preset values for the selected battery type. For preset values, see Chapter 3.7.
System Voltage

Available options: 12V / 24V / 36V / 48V.

Maximum Charging Current

The setting range is: 2~60A, with a step size of 1A.

Boost Charging Voltage

The setting range is: 9.0~17.0V, with a step size of 0.1V.

Float Charging Voltage

The setting range is: 9.0~17.0V, with a step size of 0.1V.

Under-Voltage Recovery Voltage

The setting range is: 9.0~17.0V, with a step size of 0.1V.

Under-Voltage Cutoff Voltage

The setting range is: 9.0~17.0V, with a step size of 0.1V.

6.7 Charging Voltage Parameters for Different Battery Types

For Lead-Acid Batteries and User-Defined Batteries:

ParameterFLdGELSELUSE
Boost Charging Voltage14.6V14.2V14.4V9.0~17.0V
Float Charging Voltage13.8V13.8V13.8V9.0~17.0V
Under Voltage Cutoff Voltage11.0V11.0V11.0V9.0~17.0V
Under Voltage Recovery Voltage12.6V12.6V12.6V9.0~17.0V

For Ternary Lithium Batteries:

ParameterN03N06N07N13N14
Boost Charging Voltage12.5V25.0V29.2V54.2V58.3V
Float Charging Voltage12.2V24.4V28.5V52.9V56.9V
Under Voltage Cutoff Voltage8.4V16.8V19.6V36.4V39.2V
Under Voltage Recovery Voltage9.0V18.0V21.0V39.0V42.0V

For Lithium Iron Phosphate (LiFePO4) Batteries:

ParameterL04L07L08L15L16
Boost Charging Voltage14.5V25.4V29.0V54.4V58.0V
Float Charging Voltage13.8V24.1V27.6V51.8V55.2V
Under Voltage Cutoff Voltage11.2V19.6V22.4V42.0V44.8V
Under Voltage Recovery Voltage12.0V21.0V24.0V45.0V48.0V

Note:

  • The charging parameters for lead-acid batteries and user-defined batteries listed in the above table are for a 12V system voltage. For a 24V system voltage, these values should be multiplied by 2. If a lead-acid or user-defined battery with a 24V system voltage is connected, the actual charging voltage will be twice the value displayed on the screen.

6.8 Load Operation Mode Settings

To access the load operation mode settings, press and hold the DC/▼ button. Then use the BAT/▲ and DC/▼ buttons to switch between options, and press the SET / ☀ button to save and confirm.

Mode CodeDescription
00HLight Control Mode (Load output starts after sunset and stops at sunrise).
24HImmediate Load On (Press the SET button to immediately turn off the load output).
01H~23HAdjust the duration of load activation (The value indicates the duration, e.g., 01H for 1 hour, 02H for 2 hours).

7. Protection Functions

ProtectionDescription
Photovoltaic Input OvercurrentThe controller limits the battery charging current to the maximum battery current rating. Consequently, an overcurrent from the photovoltaic array input will not allow it to operate at peak power.
Photovoltaic Array Short CircuitWhen a short circuit occurs in the photovoltaic array, the controller will stop charging, and operation can be restored by eliminating the short circuit fault.
Photovoltaic Polarity ReversalIf the photovoltaic input wiring polarity is reversed, the controller will not operate, and it will not damage the controller. After proper reconnection, the controller will operate normally.
Battery OvervoltageWhen the battery voltage exceeds 15.5/31.0/46.5/62.0V, the controller will stop charging to protect the battery from overcharging damage. Please note that stopping the charging means the charging current is very low.
Battery Over-dischargeWhen the battery voltage drops to the low-voltage disconnect setpoint, the controller will stop discharging to protect the battery from over-discharge damage.
Over-temperature ProtectionWhen the temperature of the controller's heat sink exceeds 65°C, the controller will automatically begin to reduce the charging current. When the temperature exceeds 80°C, the controller will automatically shut down.

8. Troubleshooting

Fault CodeDescriptionResolution
18Photovoltaic input Voltage Too LowIncrease the photovoltaic array voltage by changing the series-parallel connection or adding more solar panels.
60Over-temperature ProtectionIn case of over-temperature, the fan will start automatically to provide efficient forced cooling.
63Battery OvervoltageCharging will automatically stop, and it will resume when the battery voltage returns to normal levels.
65Battery UndervoltageDischarging will automatically stop, and it will resume when the battery voltage rises to normal levels.
71Photovoltaic Input Voltage Too HighReduce the photovoltaic array voltage by changing the series-parallel connection or reducing the number of solar panels.
73Overcharging CurrentReduce the photovoltaic input power by decreasing the number of solar panels.

9. Maintenance

We recommend conducting the following checks and maintenance at least twice a year to ensure optimal performance:

  1. Ensure the controller is securely mounted in a clean and dry environment.
  2. Ensure proper airflow around the controller and clean any dust or debris from the heat sinks.
  3. Inspect all exposed wires for insulation damage, such as severe sun exposure, friction wear, dryness, insect or rodent damage. Repair or replace any damaged wires as necessary.
  4. Tighten all terminals and check for loose, broken, or burnt cable connections.
  5. Confirm that all system components are properly grounded.
  6. Ensure all terminals are free from corrosion, insulation damage, high temperatures, or signs of burning/discoloration, and tighten terminal screws.
  7. Check for dirt, nesting insects, and corrosion. If present, clean promptly.

WARNING: Risk of electric shock!

  • Before performing the above operations, ensure that all power sources are turned off and then follow the relevant check and operation guidelines.

10. Specifications

Solar Input Parameters

ParameterValue
Maximum Input Power (12V System)720W
Maximum Input Power (24V System)1440W
Maximum Input Power (36V System)2100W
Maximum Input Power (48V System)2800W
Input Voltage Range (12V System)20V~80V
Input Voltage Range (24V System)37V~105V
Input Voltage Range (36V System)50V~160V
Input Voltage Range (48V System)72V~160V

Battery Charging Parameters

ParameterValue
Charging TechnologyMPPT
Charging Algorithm3 stages
Battery Voltage Range9~60V
Rated Charging Current60A
Maximum Efficiency≥98.1%
Solar Utilization Rate≥99%
Self-consumption0.7W-1.2W

Load Terminal Output

ParameterValue
Rated Output Current25A
Max. Capacitive Load Capacity10000µF

Environmental Parameters

ParameterValue
Operating Temperature Range-35°C~+45°C
Humidity Range≤95%, non-condensing
Altitude<3000m

General Specification

ParameterValue
Protection LevelIP32
Dimensions221x163x77mm / 8.7x6.42x3.03in
Net Weight1442g / 3.18lb

11. Parallel Operation Guide

Parallel Operation Schematic

Parallel Operation Schematic for multiple solar charge controllers
Detailed schematic for connecting multiple PowMr solar charge controllers in parallel.

Main Modules:

  • Controller: The controller device is capable of standalone operation for individual units and can also support a maximum of 12 units in parallel operation. When operating in parallel, communication between the parallel controllers is achieved through communication lines. The parallel controllers are installed at the same horizontal height.
  • Solar Array: Each controller must be connected to a separate solar array. One solar array cannot be simultaneously connected to more than one controller. The input power connected to each controller should not exceed the rated input power of a single controller.
  • Battery Bank: Parallel controllers are connected to the same battery bank.

Parallel Installation and Wiring

  1. Step 1. Install parallel devices: Install parallel devices at the same height level with a minimum distance of approximately 75mm between devices.
  2. Step 2. Connect communication lines.
  3. Step 3. Connect all parallel controllers to the same battery bank in sequence.
  4. Step 4. Then, individually connect each controller to its respective photovoltaic array.
  5. Step 5. Finally, connect each controller to the DC load.
  6. Step 6. Set the parallel communication code for each controller; refer to the parallel communication code settings described in Section 3.6.

12. User Tips

  • Minimize Fan Noise: The controller has a heatsink and a fan. If installed in a living area, consider its placement to minimize potential resonance noise when the fan activates.
  • Battery Calibration: If you notice discrepancies between the controller's battery voltage reading and a multimeter, use the battery calibration voltage setting (Section 6.6) to ensure accurate readings.
  • Understand Voltage Settings: Familiarize yourself with the Boost Charging Voltage, Float Charging Voltage, Under-Voltage Recovery Voltage, and Under-Voltage Cutoff Voltage settings, especially if using a "User Defined" battery type, to optimize battery performance and longevity.
  • Check PDF Manual: For a detailed, original version of the manual, you can refer to the official PDF document: PowMr Solar Charge Controller User Manual (PDF).

13. Warranty and Support

Warranty Terms:

  • Within 30 days from the date of purchase, a malfunctioning controller will be replaced at no charge, provided that it has been used under normal circumstances and authorized by the company's technical personnel.
  • Within 2 years from the date of purchase, a malfunctioning controller will be repaired at no charge.

NOTE:

  • Unauthorized disassembly voids the warranty.

Declaration:

Under the following circumstances, our company reserves the right not to assume any quality warranty responsibilities:

  • Damage caused by improper transportation.
  • Damage resulting from incorrect storage, installation, or usage.
  • Damage caused by non-professionals or untrained personnel installing and operating the equipment.
  • Damage resulting from non-compliance with the instructions and safety warnings in this document.
  • Damage caused by operation in environments that do not meet the requirements specified in this document.
  • Damage due to operation beyond the parameter ranges specified in applicable technical specifications.
  • Damage resulting from unauthorized disassembly, product alteration, or software code modification.
  • Damage caused by abnormal natural conditions (force majeure), such as lightning, earthquakes, fires, storms, etc.
  • Any damage resulting from failure to adhere to local standards and regulations during the installation and operation processes.
  • Products outside the warranty period.

Contact Information:

SHENZHEN HEHEJIN INDUSTRIAL CO.,LTD

  • Tel/Fax: +86 755-28219903
  • Email: support@powmr.com
  • Web: www.powmr.com
  • Address: Henggang Street, Longgang District, Shenzhen, Guangdong, China

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.