ZTS-421L10 / HTS-521L10 Total Station Survey Instrument User Manual

Model: ZTS-421L10 / HTS-521L10

Brand: Hi-Target

1. Introduction

This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your Hi-Target ZTS-421L10 / HTS-521L10 Total Station Survey Instrument. Please read this manual thoroughly before using the instrument to ensure safe and efficient operation and to maximize its performance and lifespan.

2. Safety Information

Always observe the following safety precautions:

  • Ensure the instrument is stable on a tripod before operation to prevent tipping.
  • Avoid direct exposure of the laser beam to eyes.
  • Operate within the specified temperature range (-20°C to 50°C).
  • Keep the instrument dry and clean. It has an IP66 dust and water protection rating, but extreme conditions should be avoided.
  • Use only the specified rechargeable lithium battery and Type-C charger.

3. Product Overview

The Hi-Target ZTS-421L10 / HTS-521L10 is a high-precision total station designed for surveying applications. It features a 2-inch angle accuracy and a reflectorless range of up to 1000m.

3.1. Components

  • Telescope: For sighting targets.
  • Display: 2.8-inch 240*320 pixel highlight color display.
  • Keypad: 2-sided alphanumeric backlit silicone keyboard with a trigger key.
  • Leveling Screws: For precise leveling of the instrument.
  • Battery Compartment: Houses the rechargeable lithium battery.
  • Interface Ports: Standard RS232, USB for data transfer.
Front view of the ZTS-421L10 / HTS-521L10 Total Station
Figure 1: Front view of the Total Station, showing the main body and display.
Rear view of the ZTS-421L10 / HTS-521L10 Total Station
Figure 2: Rear view of the Total Station, displaying the model number ZTS-421L10.
Side view of the total station with a red dot indicating the laser plummet location
Figure 3: Side view of the Total Station, highlighting the laser plummet location at the base.

4. Setup

Follow these steps to set up your total station:

  1. Mounting: Securely attach the total station to a stable tripod.
  2. Leveling: Use the leveling screws at the base of the instrument to achieve a perfectly level position. The dual-axis liquid tilt sensor assists in precise leveling.
  3. Power On: Ensure the battery is charged and correctly inserted. Press the power button to turn on the instrument.
  4. Initial Settings: The display will show initial measurement data or a main menu.
Close-up of the total station's leveling screws
Figure 4: Close-up view of the leveling screws for instrument adjustment.

5. Operating Instructions

The total station offers various measurement modes and functions. Navigate through the menus using the alphanumeric keypad.

5.1. Basic Angle Measurement

Upon powering on, the instrument typically displays angle measurement data (Vz: Vertical Angle, HR: Horizontal Angle).

Total station display showing angle measurement data
Figure 5: Display showing current vertical and horizontal angle readings.

5.2. Main Menu Navigation

Access the main menu to select different functions such as Surveying, Stakeout, or Program settings.

Total station display showing the main menu with options like Surveying, Stake, F1-man, Program, Options
Figure 6: Main menu interface for selecting operational modes.

5.3. Quick Setup

The Quick Setup menu allows for rapid configuration of measurement parameters like Mode (e.g., Single), Reflectivity (e.g., NP for Non-Prism), and Light settings.

Total station display showing the Quick Setup menu
Figure 7: Quick Setup menu for adjusting measurement parameters.

5.4. Video Demonstration

Watch this video for a visual guide on operating the total station, including screen interaction and rotation.

Play video
Watch video online
Video 1: Demonstration of the total station's physical rotation and display interaction.

6. Maintenance

  • Cleaning: Use a soft, lint-free cloth to clean the display and optical components. Do not use abrasive cleaners.
  • Storage: Store the instrument in its protective case in a dry, temperature-controlled environment when not in use.
  • Battery Care: Fully charge the battery before extended storage and recharge periodically to maintain battery health.
  • Calibration: Regular calibration by qualified personnel is recommended to maintain accuracy.

7. Troubleshooting

7.1. Common Issues

  • Instrument not powering on: Check battery charge and ensure it is properly seated.
  • Inaccurate measurements: Verify instrument leveling and ensure proper calibration. Check for obstructions in the line of sight.
  • Display issues: Ensure the display is clean and free from moisture. Adjust brightness settings if necessary.
  • Data transfer problems: Check USB/RS232 cable connections and Bluetooth pairing. Ensure correct data format (ASCII).

8. Specifications

FeatureSpecification
Angle Measurement
Angle Measuring PrincipleAbsolute Encoding
Minimum Readout1"
Accuracy2"
Distance Measurement (Prism Mode)
Single prism (General/Good Atmosphere)5000m/6000m
Accuracy (Fine/Quick/Tracking)2mm + 2ppm
Measuring Time (Repeat/Tracking)0.5s/0.3s
Distance Measurement (Reflectorless)
Range (Kodak white board with reflect rate of 90%)1000m
Accuracy3mm + 2ppm
Measuring TimeApprox. 1s
Telescope
Magnification30x
Field of View1°30'
Minimum Focusing Distance1.5m
ReticleIlluminated
Tilt Sensor
SystemDual-axis liquid tilt sensor
Working Range±3'
Accuracy1"
Communication
Internal Data MemoryApprox. 80,000 Points
InterfaceStandard RS232, USB
Wireless communicationBluetooth
Data FormatASCII
Power Supply
Battery TypeRechargeable high-energy lithium battery (Type-C for direct charging)
Voltage/Capacity7.4V DC / 3000 mAH
Operating TimeOptimal 36 hours (Continuous angle measurement, Automatic sensor every 30 seconds) / 18 hours (typical)
Measuring TimesApprox. 30000 times
Other
Display2.8 inch 240*320 pixel highlight color display
Keyboard2 sides alphanumeric backlit silicone keyboard. Trigger key.
Plummet TypeLaser point, 4 brightness levels adjustment / Optical plummet (optional)
Environment
Operating Temperature-20°C~50°C
Storage Temperature-40°C~70°C
Temperature and Air Pressure InputAutomatic sensor
Dust&Water Proof (IEC60529 Standard)IP66

9. Warranty and Support

The Hi-Target ZTS-421L10 / HTS-521L10 Total Station Survey Instrument comes with a 1-year warranty. For technical support or warranty claims, please contact your authorized dealer or the manufacturer directly.

10. User Tips

  • Language Settings: The operating language is English. If you require support in other languages, please consult the manufacturer or your local distributor for available options or language packs.
  • Accessories: Ensure all necessary accessories for your specific surveying tasks are acquired, such as prisms, tripods, and data transfer cables.