1. Introduction
This manual provides essential information for the safe and efficient operation of your TTNergy 48V MPPT 150A 11KW Solar Inverter. This multi-function inverter/charger combines the capabilities of an inverter, solar charger, and battery charger to deliver uninterrupted power. It features a comprehensive LCD display for user-configurable settings and easy operation.
The TTNergy solar inverter is designed for high performance, reliability, and user-friendliness, supporting both on-grid and off-grid applications. It is adaptable to various power needs, including compensating for weak or intermittent grids.

2. Setup and Installation
2.1 Unboxing and Inspection
Upon receiving your inverter, carefully open the packaging and inspect the contents for any damage. Ensure all components are present as listed in the packing list.

2.2 Physical Installation
The inverter should be installed in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Ensure sufficient clearance around the unit for proper airflow. The unit is designed for wall mounting.
2.3 Connections
Refer to the diagrams below for proper connection of solar panels, batteries, utility grid, and loads. Always ensure all connections are secure and follow local electrical codes.


Key Connection Points:
- Remote LCD Port: For connecting an optional remote LCD module.
- Dry Contact (Genset Starter): For generator auto-start functionality.
- BMS Port: For Battery Management System communication (CAN, RS-485, or RS-232).
- RS232 Port: For serial communication.
- Battery Input: Connect to your 48V battery bank.
- AC Output (Load): Connect to your household loads.
- AC Input: Connect to the utility grid or generator.
- PV Input: Connect to your solar panel array (PV1 and PV2).
- Parallel Communication Port: For connecting multiple inverters in parallel.
- USB Port: For USB On-the-Go function and communication.
- RGB LED Bar: Indicates output source and charge status.
- 12V DC Output Connectors (Option): For low-power DC devices like fans or routers.
2.4 Parallel Connection
The TTN-MAX series supports parallel operation of up to 6 units to increase overall system capacity. Refer to the diagram below for power and communication connections in parallel configurations.

3. Operating Instructions
3.1 Control Panel and Indicators
The inverter features an intuitive control panel with an LCD display, status indicators, and function buttons for easy monitoring and configuration.

LED Indicators:
| LED Indicator | Color | Solid/Flashing | Messages |
|---|---|---|---|
| Setting LED 1 | Green | Solid On | Output powered by utility |
| Setting LED 2 | Green | Solid On | Output powered by PV |
| Setting LED 3 | Green | Solid On | Output powered by battery |
| Status indicators (AC) | Green | Solid On | Output is available in line mode |
| Status indicators (INV) | Green | Flashing | Output is powered by battery in battery mode |
| Status indicators (CHG) | Green | Solid On | Battery is fully charged |
| Status indicators (CHG) | Green | Flashing | Battery is charging |
3.2 Mobile Monitoring (WiFi)
The inverter includes built-in WiFi for mobile monitoring. Android and iOS applications are available to track performance and status remotely.
4. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.
- Cleaning: Keep the inverter's exterior clean and free from dust. The unit features a built-in anti-dust kit for increased reliability in harsh environments.
- Fan Replacement: The inverter has a replaceable fan design for ease of maintenance. Refer to the detailed instructions in the full manual for fan replacement procedures.
- Connections Check: Periodically check all electrical connections (PV, battery, AC input/output) to ensure they are tight and free from corrosion.
- Software Updates: Keep the mobile monitoring application and inverter firmware updated for the best performance and features.
5. Troubleshooting
If you encounter issues with your inverter, refer to the following common problems and solutions. For more complex issues, consult a qualified technician.
| Problem | Possible Cause | Solution |
|---|---|---|
| Inverter not turning on | No battery connection or low battery voltage; AC input not present; Power switch off. | Check battery connections and voltage; Verify AC input; Ensure power switch is ON. |
| No AC output | Overload; Short circuit; Inverter fault. | Reduce load; Check for short circuits; Refer to fault indicator messages. |
| Battery not charging | PV input too low or absent; AC input absent; Charger settings incorrect. | Check solar panel connections and sunlight; Verify AC input; Adjust charger settings via LCD. |
| Inverter making unusual noises | Overload; Fan obstruction; Internal component issue. | Reduce load; Check for fan obstructions; Contact support if noise persists. |
6. Specifications
Below are the detailed specifications for the TTNergy TTN-MAX 11000 model. Specifications for other models (TTN-Max 8000, 7200, 6500) are also provided for comparison.
| Feature | TTN-Max 11000 | TTN-Max 8000 | TTN-Max 7200 | TTN-Max 6500 |
|---|---|---|---|---|
| Capacity | 11000VA/11000W | 8000VA/8000W | 7200VA/7200W | 6500VA/6500W |
| Parallel Operation | Yes, up to 6 units | |||
| INPUT | ||||
| Selectable Voltage Range | 230 VAC | 120 VAC | ||
| Frequency Range (230V) | 170-280 VAC (PC); 90-280 VAC (Home Appliances) | 90-140 VAC (PC); 80-140 VAC (Home Appliances) | ||
| OUTPUT | ||||
| AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% | 120 VAC ± 5% | ||
| Surge Power | 22000VA | 15000VA | 15000VA | 13000VA |
| Efficiency (Peak) | 90%~93% | |||
| Transfer Time | 15ms (PC); 20ms (Home Appliances) | |||
| Waveform | Pure sine wave | |||
| No Load Power Consumption | <70W | |||
| BATTERY | ||||
| Battery Voltage | 48 VDC | |||
| Floating Charge Voltage | 54 VDC | |||
| Overcharge Protection | 66 VDC | |||
| SOLAR CHARGER & AC CHARGER | ||||
| Solar Charger Type | MPPT | |||
| Max. PV Array Open Circuit Voltage | 500VDC | 250VDC | ||
| MPP Range @ Operating Voltage | 90~450VDC | 90~230VDC | ||
| Max. PV Array Power | 11000W (5500W×2) | 8000W (4000W x2) | ||
| Max. Solar Charge Current | 150 A | 80 A | 120A | |
| Max. AC Charge Current | 150 A | 80 A | 120A | |
| Max. Charge Current | 150 A | 120 A | 80 A | 120A |
| PHYSICAL | ||||
| Dimension, DxWxH (mm) | 147.4 × 432.5 × 553.6 | |||
| Net Weight (kgs) | 18.4 | |||
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact | |||
| ENVIRONMENT | ||||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |||
| Operating Temperature | -10°C to 50°C | -10°C to 40°C | ||
| Storage Temperature | -15°C to 60°C | |||
Note: The correct matching of battery capacity for the system depends on specific load requirements and application scenarios. Incorrect matching can lead to insufficient battery capacity or wasted power generation. Refer to the full manual recommendation or consult customer service for detailed guidance.
7. User Tips
- For optimal performance, ensure your solar panel array voltage is within the MPPT operating voltage range (90-450 VDC for TTN-Max 11000).
- Utilize the built-in WiFi for mobile monitoring to keep track of your system's performance and status from anywhere.
- When connecting multiple inverters in parallel, ensure all power and communication connections are correctly established as per the provided diagrams to prevent system malfunctions.
- Regularly check the anti-dust filter and clean it to maintain product reliability, especially in harsh environments.
- Consider using the optional DC output for low-power devices to maximize efficiency and reduce AC-DC conversion losses.
8. Warranty and Support
The TTNergy Solar Inverter comes with a 2-year warranty. For warranty claims, technical support, or service inquiries, please contact your authorized dealer or TTNergy customer service. Ensure you have your product model and serial number available when contacting support.
For further assistance, you may contact:
- Email: 1620972590@qq.com
- WhatsApp: +86 18900786512
- WeChat: +8618900786512