1. Introduction
This manual provides essential information for the safe and efficient operation of your TTN-MAX series solar inverter. The TTN-MAX is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings and easy operation.
The TTN-MAX series is designed for higher yields, safe and reliable performance, smart functionality, and user-friendliness. It is adaptable to modern energy trends and supports various configurations for optimal energy management.
2. Safety Information
WARNING: Before installing or using the inverter, please read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- Installation must be performed by qualified personnel.
- Ensure all wiring is correctly sized and properly connected.
- Do not disassemble the inverter. There are no user-serviceable parts inside.
- Keep the inverter away from flammable materials and moisture.
- Ensure adequate ventilation around the inverter to prevent overheating.
- Always disconnect all power sources (PV, AC, and battery) before performing any maintenance or wiring.
3. Package Contents
Upon unpacking, please ensure all items listed below are included and undamaged. If anything is missing or damaged, contact your supplier immediately.

- TTN-MAX Solar Inverter Unit
- User Manual
- Communication Cable (USB/RS232)
- Parallel Communication Cable (if applicable)
- Battery Cables
- PV Connectors
- Mounting Hardware
- Anti-dust kit (pre-installed or separate)
4. Product Overview
The TTN-MAX series inverter is designed to integrate solar power, utility grid, generator, and battery storage to power home appliances. It features a robust design with various communication and connection ports.

4.1 Key Features
- Pure Sine Wave output with power factor 1.0.
- Parallel operation capability up to 6 units.
- High PV input power (Max 8000W for 8KW model, 11000W for 11KW model) with dual MPPT trackers (each 4000W or 5500W).
- Built-in integrated MPPT module (120A or 150A depending on model).
- Battery independent design.
- Built-in anti-dust kit for increased reliability in harsh environments.
- Built-in Wi-Fi for mobile monitoring (Android/iOS apps available).
- Supports USB On-the-Go function.
- Lithium battery BMS support (Pylontech, Weco, Soltaro).
- Replaceable fan design for ease of maintenance.
- Batteryless operation (single unit mode only).
- Configurable AC/PV output usage timer and prioritization.
- Selectable high power charging current.
- Selectable input voltage range for home appliances and personal computers.
- Compatible with utility mains or generator input.
- Optional DC output for DC fan, LED bulb, router, etc.
- Detachable LCD remote display.
- High PV input design, 500V (Voc) max input.

4.2 Inverter Components and Ports

- LCD display
- Status indicator
- Charging indicator
- Fault indicator
- Function buttons
- Power on/off switch
- AC input connectors
- AC output connectors (Load connection)
- PV connectors
- Battery connectors
- Remote LCD module communication Port
- Current sharing port
- Parallel communication port
- Dry contact
- USB port as USB communication port and USB function port
- BMS communication port: CAN, RS-485 or RS-232
- Output source indicators (refer to OPERATION/Operation and Display Panel section for details) and USB function setting reminder (refer to OPERATION/Function Setting for the details)
- RS-232 communication port
- RGB LED bar (refer to LCD Setting section for the details)
- 12V DC output connectors (option)
- Power switch for DC output (option)

5. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.
5.1 Site Selection
- Mount the inverter vertically on a wall or suitable sturdy surface.
- Ensure the installation area is well-ventilated and free from direct sunlight, heat sources, and moisture.
- Maintain adequate clearance around the inverter for proper airflow.
5.2 Wiring Connections
CAUTION: All wiring must comply with local and national electrical codes. Ensure all power sources are disconnected before making any connections.
- Battery Connection: Connect the battery bank to the Battery Connectors (10) on the inverter. Ensure correct polarity (+ to + and - to -).
- PV Connection: Connect your solar panels to the PV Connectors (9). The inverter supports a high PV input voltage range of 90-450 VDC.
- AC Input Connection: Connect the utility grid or generator AC input to the AC Input Connectors (7).
- AC Output Connection: Connect your home appliances (load) to the AC Output Connectors (8).
- Communication Connections:
- Remote LCD Module: Connect the remote LCD module to the Remote LCD module communication Port (11).
- Parallel Communication: For parallel operation, connect the Parallel communication port (13) and Current sharing port (12) between multiple inverters.
- USB/RS232/RS485/WiFi: Use the respective ports (15, 16, 18) for monitoring and communication.
- Dry Contact: The Dry contact (14) can be used for generator starting.
5.3 Parallel Operation
The TTN-MAX series supports parallel operation of up to 6 units to increase overall power capacity. Refer to the diagrams below for power and communication connections in parallel configurations.


6. Operating the Inverter
6.1 Display Panel and Indicators
The inverter features an LCD display and various LED indicators to show its status and operational parameters.

| LED Indicator | Color | Solid/Flashing | Messages |
|---|---|---|---|
| Setting LED 1 | Green | Solid On | Output powered by utility |
| Solid On | Output powered by PV | ||
| Solid On | Output powered by battery | ||
| Status indicators AC | Green | Solid On | Output is available in line mode |
| Flashing | Output is powered by battery in battery mode | ||
| Status indicators CHG | Green | Solid On | Battery is fully charged |
| Flashing | Battery is charging. |
6.2 Initial Startup
- After all connections are made, turn on the battery breaker.
- Press the Power On/Off switch (6) to power on the inverter.
- The LCD display will light up, and the inverter will perform a self-test.
- Configure settings such as battery type, charging current, and AC/solar charger priority via the function buttons (5) and LCD display.
6.3 Mobile Monitoring
The inverter includes built-in Wi-Fi for mobile monitoring. Download the dedicated app (available for Android and iOS) to monitor system performance, adjust settings, and receive alerts remotely.
This video demonstrates the features and connectivity of the TTN-MAX solar inverter, including its parallel operation capabilities and various input/output ports.
7. Maintenance
Regular maintenance ensures the longevity and optimal performance of your inverter.
- Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but occasional cleaning is still recommended.
- Fan Replacement: The inverter features a replaceable fan design for ease of maintenance. If the fan becomes noisy or stops working, it can be replaced by a qualified technician.
- Connections Check: Annually, check all electrical connections for tightness and corrosion.
- Battery Health: Monitor battery voltage and health regularly, especially if using lead-acid batteries. Follow battery manufacturer guidelines for maintenance.
- Firmware Updates: Check for available firmware updates via the mobile app or manufacturer's website to ensure optimal performance and access to new features.
8. Troubleshooting
This section covers common issues and their potential solutions. For more complex problems, contact technical support.
- Inverter not turning on: Check battery connections, battery voltage, and the power on/off switch. Ensure the battery breaker is closed.
- No AC output: Verify AC input (utility/generator) is present. Check for fault indicators on the display. Ensure the load is properly connected.
- Battery not charging: Check PV connections and solar panel output. Verify AC input if AC charging is enabled. Check charging settings on the LCD.
- Fault indicator active: Refer to the LED indicator table in Section 6.1 for specific fault messages and consult the full manual for detailed troubleshooting steps.
- Overheating: Ensure adequate ventilation around the inverter. Clean any dust from the vents. Reduce load if consistently overheating.
9. Specifications
Technical specifications for the TTN-MAX series solar inverters.
| Feature | TTN-Max 11000 | TTN-Max 8000 | TTN-Max 7200 | TTN-Max 6500 |
|---|---|---|---|---|
| Capacity | 11000VA/11000W | 8000VA/8000W | 7200VA/7200W | 6500VA/6500W |
| Parallel Operation | Yes, up to 6 units | |||
| INPUT | ||||
| Selectable Voltage Range | 230 VAC | 120 VAC | ||
| Frequency Range | 170-280 VAC (PC); 90-280 VAC (Home Appliances) | 90-140 VAC (PC); 80-140 VAC (Home Appliances) | ||
| OUTPUT | ||||
| AC Voltage Regulation (Batt. Mode) | 230 VAC ± 5% | 120 VAC ± 5% | ||
| Surge Power | 22000VA | 15000VA | 15000VA | 13000VA |
| Efficiency (Peak) | 90%~93% | |||
| Transfer Time | 15ms (PC); 20ms (Home Appliances) | |||
| Waveform | Pure sine wave | |||
| No Load Power Consumption | <70W | |||
| BATTERY | ||||
| Battery Voltage | 48 VDC | |||
| Floating Charge Voltage | 54 VDC | |||
| Overcharge Protection | 66 VDC | |||
| SOLAR CHARGER & AC CHARGER | ||||
| Solar Charger Type | MPPT | |||
| Max. PV Array Open Circuit Voltage | 500VDC | 250VDC | ||
| MPP Range @ Operating Voltage | 90~450VDC | 90~230VDC | ||
| Max. PV Array Power | 11000W (5500W×2) | 8000W (4000W x2) | ||
| Max. Solar Charge Current | 150 A | 80 A | 120A | |
| Max. AC Charge Current | 150 A | 80 A | 120A | |
| Max. Charge Current | 150 A | 120 A | 80 A | 120A |
| PHYSICAL | ||||
| Dimension, DxWxH (mm) | 147.4×432.5×553.6 | |||
| Net Weight (kgs) | 18.4 | |||
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact | |||
| ENVIRONMENT | ||||
| Humidity | 5% to 95% Relative Humidity (Non-condensing) | |||
| Operating Temperature | -10°C to 50°C | -10°C to 40°C | ||
| Storage Temperature | -15°C to 60°C | |||
Note:
The correct matching of battery capacity for the system is determined by the specific usage requirements of the load and application scenarios. Incorrect matching can lead to insufficient battery capacity or excessive waste of power generation. For detailed recommendations, please refer to the full manual or consult technical support.
10. User Tips
- Battery Compatibility: The TTN-MAX inverter is compatible with various battery types including Flooded (FLD), Gel (GEL), AGM, Lithium (LI), Sealed (SLD), and user-customizable battery settings. Ensure your battery type is correctly configured in the inverter settings for optimal charging and discharge cycles.
- Parallel Operation Planning: When planning for parallel operation, carefully review the power and communication connection diagrams to ensure proper setup and synchronization of multiple units.
- Remote Monitoring: Utilize the built-in Wi-Fi and mobile app for convenient remote monitoring of your system's performance and status. This allows for proactive management and troubleshooting.

11. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Ensure you have your product model number and serial number available when contacting support.