TTNergy TTN-MAX

Contents

TTN-MAX Series Solar Inverter User Manual

Models: TTN-MAX 6500W, TTN-MAX 7200W, TTN-MAX 8000W, TTN-MAX 11000W

1. Introduction

This manual provides essential information for the safe and efficient operation of your TTN-MAX series solar inverter. The TTN-MAX is a multi-function inverter/charger that combines the capabilities of an inverter, solar charger, and battery charger to provide uninterruptible power support. It features a comprehensive LCD display for user-configurable settings and easy operation.

The TTN-MAX series is designed for higher yields, safe and reliable performance, smart functionality, and user-friendliness. It is adaptable to modern energy trends and supports various configurations for optimal energy management.

2. Safety Information

WARNING: Before installing or using the inverter, please read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.

  • Installation must be performed by qualified personnel.
  • Ensure all wiring is correctly sized and properly connected.
  • Do not disassemble the inverter. There are no user-serviceable parts inside.
  • Keep the inverter away from flammable materials and moisture.
  • Ensure adequate ventilation around the inverter to prevent overheating.
  • Always disconnect all power sources (PV, AC, and battery) before performing any maintenance or wiring.

3. Package Contents

Upon unpacking, please ensure all items listed below are included and undamaged. If anything is missing or damaged, contact your supplier immediately.

Inverter packaging with accessories
The inverter is securely packaged with foam inserts and includes necessary accessories such as communication cables and connectors.
  • TTN-MAX Solar Inverter Unit
  • User Manual
  • Communication Cable (USB/RS232)
  • Parallel Communication Cable (if applicable)
  • Battery Cables
  • PV Connectors
  • Mounting Hardware
  • Anti-dust kit (pre-installed or separate)

4. Product Overview

The TTN-MAX series inverter is designed to integrate solar power, utility grid, generator, and battery storage to power home appliances. It features a robust design with various communication and connection ports.

System diagram showing solar power, generator, utility grid, battery packs connected to the inverter, powering home appliances.
System diagram illustrating how the TTN-MAX inverter integrates various power sources to supply home appliances.

4.1 Key Features

  • Pure Sine Wave output with power factor 1.0.
  • Parallel operation capability up to 6 units.
  • High PV input power (Max 8000W for 8KW model, 11000W for 11KW model) with dual MPPT trackers (each 4000W or 5500W).
  • Built-in integrated MPPT module (120A or 150A depending on model).
  • Battery independent design.
  • Built-in anti-dust kit for increased reliability in harsh environments.
  • Built-in Wi-Fi for mobile monitoring (Android/iOS apps available).
  • Supports USB On-the-Go function.
  • Lithium battery BMS support (Pylontech, Weco, Soltaro).
  • Replaceable fan design for ease of maintenance.
  • Batteryless operation (single unit mode only).
  • Configurable AC/PV output usage timer and prioritization.
  • Selectable high power charging current.
  • Selectable input voltage range for home appliances and personal computers.
  • Compatible with utility mains or generator input.
  • Optional DC output for DC fan, LED bulb, router, etc.
  • Detachable LCD remote display.
  • High PV input design, 500V (Voc) max input.
Diagram highlighting inverter features: RGB light, communication for remote panel, parallel connectors, USB On-the-Go, dry contact, BMS communication, anti-dust filter, and DC output connectors.
Detailed diagram showcasing the various features and connectivity options of the TTN-MAX inverter.

4.2 Inverter Components and Ports

Diagram of the inverter's rear panel with numbered components and ports.
Rear panel layout of the inverter with labeled connection points.
  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input connectors
  8. AC output connectors (Load connection)
  9. PV connectors
  10. Battery connectors
  11. Remote LCD module communication Port
  12. Current sharing port
  13. Parallel communication port
  14. Dry contact
  15. USB port as USB communication port and USB function port
  16. BMS communication port: CAN, RS-485 or RS-232
  17. Output source indicators (refer to OPERATION/Operation and Display Panel section for details) and USB function setting reminder (refer to OPERATION/Function Setting for the details)
  18. RS-232 communication port
  19. RGB LED bar (refer to LCD Setting section for the details)
  20. 12V DC output connectors (option)
  21. Power switch for DC output (option)
Close-up view of the inverter's bottom ports including Remote LCD, Dry Contact, BMS, RS232, Battery Input, AC Output, AC Input, and PV Input.
Detailed view of the inverter's input/output and communication ports.

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your inverter. Please follow these guidelines carefully.

5.1 Site Selection

  • Mount the inverter vertically on a wall or suitable sturdy surface.
  • Ensure the installation area is well-ventilated and free from direct sunlight, heat sources, and moisture.
  • Maintain adequate clearance around the inverter for proper airflow.

5.2 Wiring Connections

CAUTION: All wiring must comply with local and national electrical codes. Ensure all power sources are disconnected before making any connections.

  1. Battery Connection: Connect the battery bank to the Battery Connectors (10) on the inverter. Ensure correct polarity (+ to + and - to -).
  2. PV Connection: Connect your solar panels to the PV Connectors (9). The inverter supports a high PV input voltage range of 90-450 VDC.
  3. AC Input Connection: Connect the utility grid or generator AC input to the AC Input Connectors (7).
  4. AC Output Connection: Connect your home appliances (load) to the AC Output Connectors (8).
  5. Communication Connections:
    • Remote LCD Module: Connect the remote LCD module to the Remote LCD module communication Port (11).
    • Parallel Communication: For parallel operation, connect the Parallel communication port (13) and Current sharing port (12) between multiple inverters.
    • USB/RS232/RS485/WiFi: Use the respective ports (15, 16, 18) for monitoring and communication.
    • Dry Contact: The Dry contact (14) can be used for generator starting.

5.3 Parallel Operation

The TTN-MAX series supports parallel operation of up to 6 units to increase overall power capacity. Refer to the diagrams below for power and communication connections in parallel configurations.

Wiring diagrams for 2, 3, 4, 5, and 6 inverters in parallel, showing power and communication connections.
Parallel connection diagrams for power and communication for 2 to 6 inverters.
Parallel connection diagrams for two inverters in each phase, three inverters in one phase and two inverters for the remaining phases, and four inverters in one phase and one for the other two phases.
Advanced parallel connection diagrams for single-phase and three-phase systems.

6. Operating the Inverter

6.1 Display Panel and Indicators

The inverter features an LCD display and various LED indicators to show its status and operational parameters.

Inverter display panel with LED display, status indicators, charging indicator, fault indicator, function buttons, and power on/off switch. Includes a table of LED indicator messages.
Inverter display panel and LED indicator meanings.
LED IndicatorColorSolid/FlashingMessages
Setting LED 1GreenSolid OnOutput powered by utility
Solid OnOutput powered by PV
Solid OnOutput powered by battery
Status indicators ACGreenSolid OnOutput is available in line mode
FlashingOutput is powered by battery in battery mode
Status indicators CHGGreenSolid OnBattery is fully charged
FlashingBattery is charging.

6.2 Initial Startup

  1. After all connections are made, turn on the battery breaker.
  2. Press the Power On/Off switch (6) to power on the inverter.
  3. The LCD display will light up, and the inverter will perform a self-test.
  4. Configure settings such as battery type, charging current, and AC/solar charger priority via the function buttons (5) and LCD display.

6.3 Mobile Monitoring

The inverter includes built-in Wi-Fi for mobile monitoring. Download the dedicated app (available for Android and iOS) to monitor system performance, adjust settings, and receive alerts remotely.

This video demonstrates the features and connectivity of the TTN-MAX solar inverter, including its parallel operation capabilities and various input/output ports.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Periodically clean the exterior of the inverter with a dry cloth. Ensure ventilation openings are free from dust and debris. The built-in anti-dust kit helps, but occasional cleaning is still recommended.
  • Fan Replacement: The inverter features a replaceable fan design for ease of maintenance. If the fan becomes noisy or stops working, it can be replaced by a qualified technician.
  • Connections Check: Annually, check all electrical connections for tightness and corrosion.
  • Battery Health: Monitor battery voltage and health regularly, especially if using lead-acid batteries. Follow battery manufacturer guidelines for maintenance.
  • Firmware Updates: Check for available firmware updates via the mobile app or manufacturer's website to ensure optimal performance and access to new features.

8. Troubleshooting

This section covers common issues and their potential solutions. For more complex problems, contact technical support.

  • Inverter not turning on: Check battery connections, battery voltage, and the power on/off switch. Ensure the battery breaker is closed.
  • No AC output: Verify AC input (utility/generator) is present. Check for fault indicators on the display. Ensure the load is properly connected.
  • Battery not charging: Check PV connections and solar panel output. Verify AC input if AC charging is enabled. Check charging settings on the LCD.
  • Fault indicator active: Refer to the LED indicator table in Section 6.1 for specific fault messages and consult the full manual for detailed troubleshooting steps.
  • Overheating: Ensure adequate ventilation around the inverter. Clean any dust from the vents. Reduce load if consistently overheating.

9. Specifications

Technical specifications for the TTN-MAX series solar inverters.

FeatureTTN-Max 11000TTN-Max 8000TTN-Max 7200TTN-Max 6500
Capacity11000VA/11000W8000VA/8000W7200VA/7200W6500VA/6500W
Parallel OperationYes, up to 6 units
INPUT
Selectable Voltage Range230 VAC120 VAC
Frequency Range170-280 VAC (PC); 90-280 VAC (Home Appliances)90-140 VAC (PC); 80-140 VAC (Home Appliances)
OUTPUT
AC Voltage Regulation (Batt. Mode)230 VAC ± 5%120 VAC ± 5%
Surge Power22000VA15000VA15000VA13000VA
Efficiency (Peak)90%~93%
Transfer Time15ms (PC); 20ms (Home Appliances)
WaveformPure sine wave
No Load Power Consumption<70W
BATTERY
Battery Voltage48 VDC
Floating Charge Voltage54 VDC
Overcharge Protection66 VDC
SOLAR CHARGER & AC CHARGER
Solar Charger TypeMPPT
Max. PV Array Open Circuit Voltage500VDC250VDC
MPP Range @ Operating Voltage90~450VDC90~230VDC
Max. PV Array Power11000W (5500W×2)8000W (4000W x2)
Max. Solar Charge Current150 A80 A120A
Max. AC Charge Current150 A80 A120A
Max. Charge Current150 A120 A80 A120A
PHYSICAL
Dimension, DxWxH (mm)147.4×432.5×553.6
Net Weight (kgs)18.4
Communication InterfaceUSB/RS232/RS485/WiFi/Dry-contact
ENVIRONMENT
Humidity5% to 95% Relative Humidity (Non-condensing)
Operating Temperature-10°C to 50°C-10°C to 40°C
Storage Temperature-15°C to 60°C

Note:

The correct matching of battery capacity for the system is determined by the specific usage requirements of the load and application scenarios. Incorrect matching can lead to insufficient battery capacity or excessive waste of power generation. For detailed recommendations, please refer to the full manual or consult technical support.

10. User Tips

  • Battery Compatibility: The TTN-MAX inverter is compatible with various battery types including Flooded (FLD), Gel (GEL), AGM, Lithium (LI), Sealed (SLD), and user-customizable battery settings. Ensure your battery type is correctly configured in the inverter settings for optimal charging and discharge cycles.
  • Parallel Operation Planning: When planning for parallel operation, carefully review the power and communication connection diagrams to ensure proper setup and synchronization of multiple units.
  • Remote Monitoring: Utilize the built-in Wi-Fi and mobile app for convenient remote monitoring of your system's performance and status. This allows for proactive management and troubleshooting.
Diagram of the 8000W MPPT Hybrid Inverter showing dimensions and compatible battery types.
Inverter dimensions and supported battery types.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your authorized dealer or the manufacturer directly. Ensure you have your product model number and serial number available when contacting support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.