1. Introduction
The ATORCH GR2PWSL is a smart Din Rail energy meter designed for real-time monitoring of electrical parameters such as voltage, current, power, and energy consumption (kWh). It integrates WiFi connectivity for remote control and data access via the Tuya or Smart Life mobile applications. This device also features advanced protection functions including leakage cutoff, over-voltage, under-voltage, over-current, and over-power protection, with an automatic power supply restoration feature after transient faults. This manual provides detailed instructions for the safe installation, setup, and operation of your GR2PWSL energy meter.

2. Safety Information
- This product is designed for unidirectional current measurement only. It is not suitable for applications involving bidirectional current, such as solar power generation systems, as it will not accurately measure negative current.
- Installation should be performed by a qualified electrician to ensure compliance with local electrical codes and safety standards.
- Always disconnect power before installing or servicing the device.
- Do not operate the device in environments exceeding its specified operating temperature range (-10°C to +60°C).
- Ensure all wiring connections are secure and correct according to the provided wiring diagram to prevent electrical hazards.
3. Product Overview
3.1 Key Features
- Real-time Monitoring: Displays voltage (V), current (A), active power (W), energy consumption (kWh), frequency (Hz), and power factor (PF).
- Leakage Protection: Integrated leakage cutoff with mutual inductance coil.
- Multi-level Protection: Over-voltage (OVP), Under-voltage (LVP), Over-current (OCP), and Over-power (OPP) protection with configurable thresholds.
- Automatic Recovery: Configurable delay for automatic power supply restoration after over-voltage or under-voltage events.
- WiFi Connectivity: Remote control and monitoring via Tuya or Smart Life mobile applications (2.4GHz WiFi only).
- Energy Statistics: Daily, monthly, and annual electricity consumption reports.
- Prepaid Function: Set an energy balance, with automatic power shutdown if the balance is insufficient.
- Flexible Pricing: Supports single rate, tiered, and peak-valley electricity pricing models.
- Firmware Upgrades: Lifetime free firmware updates via WiFi remote.
- Multiple Display Modes: Four standby display styles: Original, Large Font, Time Calendar, and Screen Off.
- 13-in-1 Function Test Interface: Comprehensive display of various parameters and protection statuses.
3.2 Package Contents
- GR2PWSL Smart Din Rail Energy Meter (with WiFi module and built-in relay) x 1
- Mutual Inductance Coil x 1
- User Manual x 1

4. Specifications
| Attribute | Specification |
|---|---|
| Model Number | GR2PWSL |
| Dimensions | 90.80 x 69.80 x 36.00 mm |
| Installation | 35mm Din rail |
| Operating Temperature | -10°C ~ +60°C |
| Rated Voltage | 220V AC |
| Output Voltage Range | AC50-320V |
| Max Operating Current | 100A |
| Accuracy Class | 1% |
| Measuring Energy Range | 0-999999KWH |
| Power Range | Max 32.0KW |
| Phase | Single phase |
| Power Supply | AC |
| Display Type | 1.50 inches TFT-LCD HD Display Panel Graphic 240x320 RGB Dot-matrix |
| Wireless Type | 2.4GHz 802.11b/g/n |
| Leakage Protection | Yes, >10mA leakage protection current |
| Battery Included | No (Built-in standby battery for time/calendar) |
| Certification | CE, RoHS |

5. Installation
5.1 Mounting
The GR2PWSL meter is designed for installation on a standard 35mm Din rail. No screws or snap fasteners are required for mounting, making installation convenient and easy.

5.2 Wiring Diagram
Follow the diagram below for correct wiring. Ensure the N-IN (Neutral Input), L-IN (Live Input), N-OUT (Neutral Output), and L-OUT (Live Output) terminals are connected properly. The mutual inductance coil is essential for leakage protection and current measurement.

5.3 Leakage Protection Coil Installation
The leakage protection function requires an external transformer induction coil to be effective. Ensure the coil is correctly installed around the live wire (L-IN or L-OUT) as indicated in the diagram. The coil has dimensions of 28mm inner diameter and 40mm outer diameter.

6. Setup
6.1 Mobile App Download
Download the "Tuya" or "Smart Life" app from your mobile app store (Google Play for Android, Apple App Store for iOS).
6.2 WiFi Network Connection
To connect the meter to your WiFi network:
- Ensure Bluetooth and location permissions are enabled on your smartphone.
- Power on the device. The red light will flash and remain on, indicating it's in distribution network mode, waiting for WiFi connection.
- Open the Smart Life or Tuya app. It should automatically detect the new device. Click "Add" to proceed.
- Select your working WiFi network and enter the password. Click "Next".
- After successful pairing, click "Next" again. The app will connect to the device.

6.3 Initial Settings (BenFang Sys Settings)
To access the backend settings, long-press the "M" key button on the device. Use the "+" and "-" buttons to navigate and select parameters. Long-press "M" again to enter the selected setting.
- Language: Select English or Chinese.
- Display Brightness: Adjust screen brightness (0-9).
- Standby Brightness: Adjust brightness during standby (0-9).
- System Sound Switch: Turn system sounds ON/OFF.
- Cost Mode Setting: Configure electricity pricing (Price-A, Price-B, Price-C for Peak-Valley).
- Zero All Data: Reset all accumulated data.
- WiFi Reset: Reset WiFi connection.
- Default Setting: Restore factory defaults.
- Over Protect Delay: Set delay for over-protection (e.g., 0.3s to prevent surge misjudgment).
- Over Protect Enable: Enable/Disable over-protection.
- Low Voltage Protect: Set low voltage protection threshold (e.g., 65.0V).
- Calibrate Time Date: Set current time and date.
- Voltage/Current/Power Calibrate Ref: For advanced calibration.
- Switch Mode Setting: Configure relay switch behavior (Mode-A, Mode-B).
- Screen Flip Setting: Rotate display (0°, 90°, 180°, 270°).
- Standby Style Setting: Choose from Default, Large Font, Calendar Time, or Screen OFF.
- Over_Recover Time: Set the delay for automatic power recovery after protection events (1-99 minutes).
- PowerOn Switch Status: Set initial relay status (Open, Close, Memory).
- Start-up Info Switch: Enable/Disable startup information display.


7. Operation
7.1 Real-time Monitoring
The meter's TFT-LCD display provides real-time data. The mobile app also offers a comprehensive interface for monitoring and control.


7.2 Power ON/OFF
Long-press the "+" or "-" buttons on the device to manually turn the power ON or OFF. The display will show the current status.

7.3 Protection Functions
The device offers five major protection functions to ensure electrical safety:
- Over Voltage Protection (OVP): Disconnects power if voltage exceeds a set threshold.
- Under Voltage Protection (LVP): Disconnects power if voltage drops below a set threshold.
- Over Current Protection (OCP): Disconnects power if current exceeds a set threshold.
- Over Power Protection (OPP): Disconnects power if total power exceeds a set threshold.
- Leakage Protection: Disconnects power if a leakage current is detected.
If a protection event occurs, the device will disconnect power. For OVP and LVP, if the voltage returns to normal within the set "Over_Recover Time" (1-99 minutes), power supply will be automatically restored.

Setting Leakage Protection Threshold
To set the leakage current threshold, long-press the "M" key to enter the settings, then press "+" and "-" simultaneously to enter the current threshold setting interface. The range is 10mA to 200mA.

7.4 Electricity Statistics and Pricing
The device provides daily, monthly, and annual electricity consumption reports. You can also configure electricity pricing models:
- Single Rate: A single price for all electricity consumption.
- Tiered Pricing: Set different prices based on consumption tiers (e.g., price changes after 1000kWh).
- Peak-Valley Pricing: Set different prices for specific time periods (e.g., 00-07H, 07-11H, 11-19H, 19-00H).


7.5 Prepaid Function
The prepaid function allows you to set an electricity balance. If the remaining balance is insufficient, the power will automatically shut down. This is useful for managing electricity expenses.

7.6 Alarm Event Notifications
You can configure the mobile app to receive notifications for various fault events, such as over-voltage alarms.
- In the Smart Life/Tuya app, go to the "Smart" tab and click the "+" icon to create a new scene.
- Select "When device status changes".
- Choose your GR2PWSL device.
- Select "Fault" and then choose the specific fault type, e.g., "over voltage alarm".
- Under "Then", add a task to "Send notification" and select "Message Center" for receiving alerts.



8. Maintenance
8.1 Firmware Upgrades
The device supports lifetime free firmware updates via WiFi remote. To upgrade, open the mobile app, navigate to the device settings (usually by clicking the upper right corner), select "device upgrade," and then "update."

9. Troubleshooting (FAQ)
- Q: Are there any charges for data cloud services?
- A: No, data cloud services are free.
- Q: What mobile applications are supported?
- A: The device supports Tuya APP and Smart Life APP, available on Google Play (Android) and Apple App Store (iOS).
- Q: Does this device support a computer application?
- A: The WiFi version does not support a computer application. A Bluetooth version (if available) might support it.
- Q: What types of mobile phones are supported?
- A: Currently, Android phones and Apple (iOS) phones are supported.
- Q: What is the size of the built-in shunt?
- A: The device has a built-in 100A shunt, so no external CT is required for current measurement up to 100A.
- Q: Is this a single-phase or three-phase meter?
- A: This is a single-phase electricity meter.
- Q: Does this product use a 2.4G or 5G network?
- A: This WiFi version supports 2.4G networks and does not currently support 5G networks.
- Q: Does the product have power-off memory?
- A: Data has power-off memory, meaning accumulated energy readings are retained. However, the switch mode (relay status) does not have power-off memory; once power is restored, the relay will close, and the screen will display normally.
10. User Tips
- When adding the device to the Smart Life or Tuya app, ensure your phone's Bluetooth and location permissions are enabled for a smoother pairing process.
- Utilize the automatic power supply restoration feature by setting an appropriate "Over_Recover Time" in the device's backend settings. This can prevent prolonged outages due to temporary voltage fluctuations.
- Regularly check for firmware updates via the mobile app to ensure you have the latest features and improvements.
11. Warranty and Support
The ATORCH GR2PWSL energy meter is certified with CE and RoHS, indicating compliance with European safety, health, and environmental protection standards.
For any questions, technical assistance, or issues encountered during the use of this product, please contact the seller directly. Provide your product model (GR2PWSL) and a detailed description of the issue for efficient support.