1. Introduction and Overview
The ZOYI ZT-703S is a versatile 3-in-1 electrical testing device, integrating a digital oscilloscope, a true RMS multimeter, and a signal generator into a single, compact unit. Designed for high-precision measurements, it features a 3.5-inch IPS color screen, dual-channel input, and a 50MHz bandwidth oscilloscope. This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your ZT-703S device.


2. Setup
2.1 Battery Installation and Charging
The ZT-703S comes with a rechargeable lithium-ion battery (3400mAh) included. Ensure the battery is properly installed before first use. To charge the device, connect it to a 5V/2A Type-C charger. A full charge ensures optimal performance and portability.

2.2 Connecting Probes
Depending on the function (oscilloscope or multimeter), connect the appropriate probes to the input terminals. For oscilloscope measurements, use the BNC connectors. For multimeter functions, use the standard banana plug inputs (10A, mA, COM, VΩHz). Ensure all connections are secure before taking measurements.
2.3 Powering On/Off
Press and hold the power button (usually marked with a circle and line) to turn the device on or off. The 3.5-inch IPS color screen will illuminate upon startup.

3. Operating Instructions
3.1 Mode Selection
Use the 'MODE' button to switch between the Oscilloscope, Multimeter, and Signal Generator functions. The current mode will be indicated on the screen.
3.2 Oscilloscope Operation
The ZT-703S features a 50MHz bandwidth oscilloscope with dual-channel synchronous input. It supports real-time sampling and various trigger modes.
- Dual-Channel Input: Connect two probes to simultaneously view and compare two different waveforms.
- Waveform Display: The device can display various waveforms, including sine, square, and triangle waves.
- Trigger Modes: Utilize multiple trigger modes (Automatic, Normal, Single) and trigger edges (Rising edge, Falling edge) to stabilize and capture specific waveform events.
- Post-Glow Mode: This feature allows for the display of waveform persistence, useful for observing transient signals or signal variations over time.
- Automatic Measurement: The device can automatically measure parameters such as Period, Frequency, Max value, Min value, Peak-to-peak value, Effective value, Duty cycle, and Coefficient.




3.3 Multimeter Operation
The ZT-703S functions as a 25000 counts True RMS multimeter, capable of measuring a wide range of electrical parameters with automatic ranging.
- Measurements: Supports measurement of DC/AC Voltage, DC/AC Current, Resistance, Capacitance, Frequency, Diode, and Continuity.
- Automatic Ranging: The 'AUTO RANGE' button allows the device to automatically select the appropriate measurement range for convenience.
- Data Hold: Use the 'HOLD SAVE' button to freeze the current reading on the display.

3.4 Signal Generator Operation
The integrated signal generator can output various waveforms for testing and calibration purposes.
- Waveform Output: Generate sine wave, square wave, triangle wave, and sawtooth wave signals.
- Parameter Adjustment: Adjust parameters such as voltage peak-to-peak (VPP) and frequency (FREQ) as needed.

3.5 Data Management
- Data Saving: The 'HOLD SAVE' button can also be used to save measurement data or waveforms.
- PC Connection: Connect the device to a computer via USB for data transfer and further analysis.

3.6 General Controls
- REL (Relative Measurement): Used for relative measurements.
- AUTO RANGE: Toggles automatic ranging on/off.
- HOLD SAVE: Holds the current reading or saves data.
- MODE: Switches between main functions (Oscilloscope, Multimeter, Signal Generator).
- MENU: Accesses device settings and options.
- Navigation Buttons: Used to navigate menus and adjust parameters.
- Language Switching: The device supports switching between different languages.
4. Features
The ZOYI ZT-703S offers a comprehensive set of features for electrical testing:
- Integrated Oscilloscope, Signal Generator, and Multimeter functions.
- Voltage Measurement capabilities.
- Upgradable firmware.
- 3.5-inch IPS color screen with full viewing angle.
- Diode and Continuity testing.
- Measurement of multiple waveform types.
- Waveform saving and data saving functions.
- Intelligent overheat protection.
- Automatic adjustment (Auto Range).
- Data transfer to PC.
- Language switching.
- True RMS measurement.

5. Specifications
5.1 General Characteristics
| Feature | Specification |
|---|---|
| Display | 25000 counts |
| Measurement Range | Automatic / Manual |
| Charge | Type-C (5V / 2A) |
| Battery Capacity | 3400 mAh |
| Supported Functions | Multimeter, Oscilloscope, Signal Generator |
| Material | ABS / TPE |
| Dimensions | 177 * 89 * 40 mm |
| Weight | 380g |
5.2 Oscilloscope Parameters
| Parameter | Specification |
|---|---|
| Bandwidth | 50 MHz, two channels |
| Sampling Method | Real-time sampling |
| Sampling Rate | 200 MSa/s |
| Input Coupling | DC, AC |
| Input Impedance | 1 MΩ, @16pF |
| Attenuation | X1, X10 |
| Record Length | Minimum 500, 15s, 10s, infinite |
| Time Base Range | 10ns/div - 20s/div |
| Time Base Accuracy | 20 ppm |
| Record Depth | Up to 128 Kbit |
| Sensitivity | 20mV/div - 10V/div |
| Offset Range | 4 grids |
| Analog Bandwidth | 50 MHz |
| Trigger Frequency | Less than 10Hz |
| Automatic Measurement | Period, Frequency, Max value, Min value, Peak-to-peak value, Effective value, Duty cycle, Coefficient |
| Trigger Mode | Automatic, Normal, Single |
| Trigger Edge | Rising edge, Falling edge |
| Signal Generator Output | Sine wave, Square wave, Triangle wave, Sawtooth wave |
| Operating Modes | YT, XY, Roll mode |
5.3 Multimeter Parameters
| Measurement | Range | Accuracy |
|---|---|---|
| DC Voltage | 1000.0V / 250.00V / 25.000V / 2.5000V | ±(0.5%+3) |
| 250.00mV | ±(0.5%+3) | |
| AC Voltage | 750.0V / 250.00V / 25.000V / 2.5000V | ±(0.5%+3) |
| 250.00mV | ±(0.5%+3) | |
| DC Current | 10.000A / 2.5000A | ±(0.5%+3) |
| 250.00mA / 25.000mA | ±(0.5%+3) | |
| AC Current | 10.000A / 2.5000A | ±(0.5%+3) |
| 250.00mA / 25.000mA | ±(0.5%+3) | |
| Resistance | 250.00KΩ / 2.5000KΩ / 2.5000Ω | ±(0.2%+3) |
| 250.00MΩ / 2.5000MΩ | ±(1%+3) | |
| 250.0MΩ | ±(5.0%+5) | |
| Capacitance | 999.9μF / 99.99μF / 9.999μF | ±(5.0%+20) |
| 999.9nF / 99.99nF | ±(5.0%+5) | |
| Frequency | 999.9Hz / 99.99Hz / 9.999kHz / 99.99kHz / 999.9kHz | ±(0.1%+2) |
| 9.999MHz | ±(0.1%+2) | |
| Diode | Yes | N/A |
| Continuity | Yes | N/A |
| DC Current Accuracy | N/A | ±3% |

6. Maintenance
6.1 Cleaning
Regularly clean the device with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off before cleaning.
6.2 Battery Care
To prolong battery life, avoid fully discharging the device frequently. Recharge the 3400mAh lithium-ion battery when the low battery indicator appears. If storing the device for an extended period, ensure it is partially charged (around 50%) and recharge it periodically.
6.3 Fuse Information
The ZT-703S is equipped with intelligent overheat protection, which includes internal fuses to safeguard the device. If the device malfunctions due to an overload, the fuses may need inspection or replacement. Refer to a qualified technician for fuse replacement to ensure proper protection and functionality.

7. Troubleshooting
If you encounter issues with your ZOYI ZT-703S, consider the following general troubleshooting steps:
- Device not powering on: Ensure the battery is charged. Connect the device to a Type-C charger and try again.
- Incorrect readings: Check probe connections. Ensure the correct mode (Oscilloscope, Multimeter) is selected for the measurement. Verify that the measurement range is appropriate (use AUTO RANGE if unsure).
- No waveform display: In oscilloscope mode, check probe connections, input coupling (AC/DC), and trigger settings. Adjust the time base and sensitivity settings.
- Signal generator not outputting: Verify the signal generator mode is active and output parameters are correctly set.
- Device unresponsive: Try performing a soft reset by holding down the power button for an extended period (e.g., 10-15 seconds) until the device restarts or powers off.
For persistent issues, please refer to the support section or contact the seller for assistance.
8. Warranty and Support
Your ZOYI ZT-703S device is backed by certain guarantees and support options:
- Free Returns: Enjoy free returns within 90 days of purchase.
- Fast Delivery Guarantee: In case of delayed delivery, a $1.00 coupon code may be provided. Refunds are available if the package is lost or items are damaged during transit, or if there is no delivery within 30 days.
- Technical Support: For any technical queries, operational difficulties not covered in this manual, or warranty claims, please contact the seller directly. Provide your purchase details and a clear description of the issue for prompt assistance.