Weidmuller WSR-ES1-3O1C-S

Weldmuller WSR-ES1-3O1C-S Safety Relay

Model: WSR-ES1-3O1C-S | Part Number: 2825510000

Manufacturer: Weidmüller Interface GmbH & Co. KG

1. Introduction

The Weldmuller WSR-ES1-3O1C-S is a high-performance safety relay designed for monitoring safety functions in industrial applications. It is certified for safety integrity levels up to SIL3, PL e, and Cat.4 according to ISO 13849, making it suitable for critical safety circuits involving E-Stop buttons and safe gates. This manual provides essential information for the safe and effective installation, operation, and maintenance of the device.

Weldmuller WSR-ES1-3O1C-S Safety Relay in packaging
Figure 1: Weldmuller WSR-ES1-3O1C-S Safety Relay in its original packaging.

2. Setup and Wiring

Proper installation and wiring are crucial for the safe and reliable operation of the WSR-ES1-3O1C-S safety relay. Ensure all power is disconnected before beginning installation.

Wiring diagram and technical specifications for Weldmuller WSR-ES1-3O1C-S Safety Relay
Figure 2: Detailed wiring diagram and technical specifications.

2.1. Power Supply Connection

  • Connect the power supply to terminals A1+ and A2-.
  • The relay operates with a supply voltage of 24V DC/AC, with a tolerance of -15% to +10%.

2.2. Input Device Connection

The safety relay is designed to monitor input devices such as E-Stop buttons and safe gates.

  • Connect input devices to terminals S11, S12, S21, S22, S34, S52 as per the application's safety circuit design. Refer to Figure 2 for the internal circuit representation.
  • Ensure that the input devices are correctly wired to provide the necessary feedback for the safety function.

2.3. Output Connection

The relay provides multiple output contacts for controlling machinery or signaling status.

  • Safety Outputs: Connect safety-related loads to terminals 13-14, 23-24, 33-34. These are Normally Open (NO) contacts.
  • Auxiliary Output: Connect auxiliary loads or signaling devices to terminals 41-42. This is a Normally Closed (NC) contact.
  • The output contacts have a drive capability of AC-15, 5A/230V and DC-13, 6A/24V. The maximum output is 250VAC/24VDC@5A.

2.4. Reset Function

The relay supports both automatic and manual reset modes. The specific configuration depends on the wiring of the reset circuit (RST terminals S34, S21, S22, S11).

  • For Auto Reset, ensure the reset circuit is configured to automatically clear faults.
  • For Manual Reset, a momentary push-button connected to the reset circuit is typically used to acknowledge and clear faults after the safety circuit is restored.

3. Operating Instructions

Once correctly installed and wired, the WSR-ES1-3O1C-S safety relay operates by monitoring the state of connected safety input devices and controlling its output contacts accordingly.

3.1. Normal Operation

  • When all safety input conditions are met (e.g., E-Stop not pressed, safe gate closed), the safety outputs (13-14, 23-24, 33-34) will close, allowing power to flow to connected machinery.
  • The auxiliary output (41-42) will open, indicating the safe state.

3.2. Safety Event Response

  • If a safety input device is activated (e.g., E-Stop pressed, safe gate opened), the relay will de-energize its safety outputs within a response time of ≤30ms, bringing the connected machinery to a safe stop.
  • The auxiliary output will return to its closed state.

3.3. Resetting the Relay

  • After a safety event, the cause of the event must be resolved.
  • Depending on the configured reset mode (Auto/Manual), the relay will either automatically reset or require a manual reset action to re-energize the safety outputs.
  • Switch ON delay: ≤300ms after reset.
  • Switch OFF delay: ≤30ms upon activation of a safety input.

4. Maintenance

The Weldmuller WSR-ES1-3O1C-S safety relay is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended to ensure continued safety and performance.

  • Visual Inspection: Regularly inspect the relay and its wiring for any signs of damage, loose connections, or corrosion.
  • Functional Testing: Periodically test the safety function by activating the connected E-Stop buttons or safe gates to ensure the relay responds correctly and de-energizes the outputs.
  • Cleaning: Keep the device free from dust and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
  • Environmental Conditions: Ensure the operating environment remains within the specified temperature range of -20°C to +60°C and free from excessive humidity or corrosive atmospheres.

Any maintenance or repair work should only be performed by qualified personnel.

5. Troubleshooting

If the safety relay does not function as expected, consider the following troubleshooting steps:

Problem Possible Cause Solution
Relay does not energize outputs
  • No power supply
  • Safety input not met (e.g., E-Stop active)
  • Incorrect wiring
  • Faulty input device
  • Check 24V DC/AC supply to A1+/A2-.
  • Verify all safety inputs are in a safe state.
  • Review wiring diagram (Figure 2) for correct connections.
  • Test input devices for proper function.
Relay does not reset
  • Safety input still active
  • Manual reset button not pressed (if configured)
  • Fault in reset circuit
  • Ensure all safety inputs are clear.
  • Press the manual reset button (if applicable).
  • Check wiring of the reset circuit.
Outputs de-energize unexpectedly
  • Intermittent fault in safety input
  • Loose wiring connection
  • External interference
  • Inspect safety input devices and wiring for intermittent issues.
  • Check all terminal connections for tightness.
  • Ensure proper grounding and shielding if interference is suspected.

If problems persist after following these steps, contact technical support.

6. Specifications

Parameter Value
Model WSR-ES1-3O1C-S
Part Number 2825510000
Input Voltage (Supply A1+, A2-) 24V DC/AC (-15% ~ +10%)
Input Devices E-Stop Button, Safe Gate
Safety Outputs 3 NO (Normally Open)
Auxiliary Output 1 NC (Normally Closed)
Output Drive Capability (AC) AC-15, 5A/230V
Output Drive Capability (DC) DC-13, 6A/24V
Max Output 250VAC/24VDC@5A
Response Time ≤30ms
Switch ON Delay ≤300ms
Switch OFF Delay ≤30ms
Reset Type Auto/Manual reset
Operating Temperature -20°C to +60°C
Certifications TÜV Rheinland, SIL3 SC3, PL e, Cat.4, ISO 13849, CE
Dimensions (L x W x H) 10 cm x 5 cm x 5 cm (approximate package dimensions)
Weight 0.2 kg (approximate package weight)

7. User Tips

  • Always double-check wiring against the provided diagram before applying power to prevent damage or unsafe conditions.
  • Regularly test the entire safety circuit, including the relay and connected input devices, to ensure proper functionality and compliance with safety standards.
  • Keep the relay's ventilation clear to ensure optimal operating temperature and longevity.

8. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the official Weidmuller documentation or contact your authorized distributor. Ensure you have the model number (WSR-ES1-3O1C-S) and part number (2825510000) available when seeking support.

Related Documents - WSR-ES1-3O1C-S

Preview Weidmüller STARTERKIT-UC20-WL2000-IOT Справочный листок технических данных
Технические данные, информация о заказе и загрузки для комплекта Weidmüller STARTERKIT-UC20-WL2000-IOT, включая вес, соответствие REACH и RoHS, а также ссылки на CAD-данные, руководства и программное обеспечение.
Preview Weidmüller POCON Operating Instructions
Comprehensive operating instructions for the Weidmüller POCON system, detailing its use in network monitoring, installation, configuration, and safety precautions for electrical interface applications.
Preview Weidmüller SAK 4 Modular Terminal Blocks: Installation Instructions and Safe Use Conditions
Comprehensive installation instructions and safety conditions for Weidmüller SAK 4 series modular terminal blocks, compliant with ATEX, IECEx, and UKCA standards for use in hazardous environments.
Preview Weidmüller UC20-SL2000-OLAC-EC Quick Start Guide for Node-RED
A comprehensive quick start guide for setting up and using Node-RED on the Weidmüller UC20-SL2000-OLAC-EC controller, covering installation and basic configuration steps.
Preview Weidmüller Industrial Connectivity Core Portfolio: Australian & New Zealand Catalogue
Explore Weidmüller's comprehensive Industrial Connectivity Core Portfolio, featuring terminals, connectors, enclosures, tools, and marking systems for Australian and New Zealand markets. Issue #1.
Preview Weidmüller IE-CS-MBGW-2TX-1COM Hardware Installation Guide
This guide provides detailed instructions for the installation and setup of the Weidmüller IE-CS-MBGW-2TX-1COM Serial/Ethernet Converter and Modbus Gateway. It covers safety notices, package contents, panel layouts, mounting dimensions, wiring, communication connections, device access, LED indicators, disposal information, and technical specifications.