SUOER VMS-V-2.2K

Contents

SUOER VMS-V-2.2K 2.2kW 12V MPPT Off-Grid Hybrid Solar Inverter

Instruction Manual

1. Introduction

This manual provides essential information for the safe and efficient operation of your SUOER VMS-V-2.2K 2.2kW 12V MPPT Off-Grid Hybrid Solar Power Inverter. Please read this manual thoroughly before installation and use, and keep it for future reference.

The SUOER VMS-V-2.2K is a pure sine wave hybrid solar inverter designed for off-grid solar systems. It integrates a solar charge controller (MPPT 80A), an AC inverter, and a battery charger into one unit, providing a comprehensive solution for energy storage and power conversion.

SUOER 2.2kW 12V Hybrid Solar Inverter, part of an energy storage system.

Figure 1: SUOER 2.2kW 12V Hybrid Solar Inverter

2. Safety Information

Please observe the following safety precautions during installation, operation, and maintenance of the inverter:

  • Installation must be performed by qualified personnel.
  • Ensure all wiring is correctly sized and properly insulated.
  • Disconnect all power sources (solar, battery, AC) before performing any maintenance or wiring.
  • Do not operate the inverter in wet conditions or near flammable materials.
  • Ensure proper ventilation around the inverter to prevent overheating.
  • The inverter has over-current and short-circuit protection functions.
  • Built-in lightning protection equipment for power grid and photovoltaic input (optional).
  • Built-in insulation testing equipment (optional).

3. Product Features

The SUOER VMS-V-2.2K Hybrid Solar Inverter offers the following key features:

  • Pure sine wave output.
  • Cold start function.
  • Selectable input voltage range for various applications (home appliances and personal computers).
  • Selectable charging current based on application needs.
  • Configurable AC/Solar input priority via LCD setting.
  • Compatible with mains voltage or generator power.
  • Auto restart function when AC power recovers.
  • Overload and short circuit protection.
  • Smart battery charger design for optimized battery performance.
  • Built-in MPPT solar charger controller (80A).
  • Wi-Fi monitoring capability via a dedicated app.
  • Single AC output.
  • Operating temperature range: -10°C to 50°C.
  • High conversion efficiency (DC/AC): 98%.
  • Grid pass-through efficiency: ≥98%.
  • Compatible with AGM/SLA, Gel, LiFePO4/Lithium, and Flooded Batteries.
Diagram showing 8 product features of the hybrid solar inverter, including AC Input 70-280V, Rated Power 2.2kW, Max Efficiency 94%, Battery Voltage 12VDC, WiFi Remote Monitoring, Single AC output, 80A MPPT Controller, and Operating Temperature -10°C~50°C.

Figure 2: Key Product Features

Product Advantage diagram highlighting Safety, Intellect, Efficient, and Environmental protection features.

Figure 3: Product Advantages

4. Specifications

SUOER 2.2KW Hybrid Solar Inverter Specifications
ParameterValue
Model Name2.2KW Hybrid Solar Inverter
Model NumberVMS-V-2.2K-12-H
ColorWhite
Operating Temperature-10°C to 50°C
Rated Power1600W
Maximum Solar Charging Current80A
Nominal Output Voltage (GRID/AC)220/230/240Vac
Feed-in Grid Voltage Range195~253Vac
Maximum Conversion Efficiency (DC/AC)98%
Nominal Operating Frequency50/60Hz
Nominal Operating Voltage (AC Input)230Vac
Maximum Input Current (AC)30A
Surge Power3000VA
Maximum AC Charging Current60A
Battery Voltage Range20~33VDC
Maximum Battery Current200A
DIY SuppliesElectrical
OriginMainland China, Guangdong
Size348x270x95mm
Weight4kg
WaveformPure sine waveform
Maximum PV Array Power2200W
Warranty1 year
Diagram showing the inverter's temperature tolerance, operating stably across a broad range from -10°C to 50°C.

Figure 4: Temperature Tolerance

5. Setup and Installation

Proper installation is crucial for the safe and efficient operation of your hybrid solar inverter. Refer to the diagrams below for typical connection setups.

5.1 Home Connection Diagram

This diagram illustrates a typical home solar system setup, connecting solar panels, the inverter, a lithium battery, and household AC loads.

Home Connection Diagram showing 6 solar panels connected to the inverter, which is connected to a lithium battery and various household loads like an AC unit, washing machine, and TV.

Figure 5: Home Connection Diagram

5.2 System Connection Diagram

This diagram provides a broader view of the system, including utility electricity, an AC/DC General Distribution Box, solar panels, a battery cabinet, and connectivity options like WLAN and 4G for cloud monitoring.

System Connection Diagram showing the hybrid inverter connected to utility electricity, an AC/DC distribution box, solar panels, and a battery cabinet. It also illustrates WLAN and 4G connectivity to a cloud platform for monitoring.

Figure 6: System Connection Diagram

5.3 Battery Compatibility

The inverter is compatible with a wide range of battery types:

  • AGM/SLA Batteries
  • Gel Batteries
  • LiFePO4/Lithium Batteries
  • Flooded Batteries
Inverter Details showing battery compatibility with AGM/SLA, Gel, LiFePO4/Lithium, Flooded Batteries, use with generators (Max AC charging current 0-63A, Input Voltage Range 90-140Vac), and Wi-Fi Monitoring via app.

Figure 7: Inverter Details - Battery Compatibility, Generator Use, and Wi-Fi Monitoring

6. Operating Instructions

6.1 Initial Power-Up

  1. Ensure all connections (solar panels, battery, AC loads, utility/generator) are secure and correct according to the installation diagrams.
  2. Turn on the battery breaker.
  3. Turn on the solar panel breaker.
  4. Turn on the AC output breaker to power your loads.
  5. If connected to utility or a generator, turn on the AC input breaker.

6.2 LCD Display and Settings

The inverter features an LCD display for monitoring system status and configuring settings. Refer to the on-site man-machine interface setting function for detailed navigation.

  • Input Voltage Range: Select between 'home appliances' or 'personal computers' mode based on your load requirements.
  • Charging Current: Adjust the charging current to optimize battery charging based on battery type and capacity.
  • AC/Solar Input Priority: Configure whether the inverter prioritizes solar power or AC utility/generator power for charging and powering loads.

6.3 Wi-Fi Monitoring

The built-in Wi-Fi transmitters allow you to monitor your hybrid inverter remotely via a dedicated Wi-Fi APP. Follow the app's instructions to connect and view system performance, battery status, and energy flow from anywhere.

7. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter.

  • Cleaning: Keep the inverter's exterior clean and free from dust. Ensure ventilation openings are not blocked. Use a dry cloth for cleaning.
  • Connections: Periodically check all electrical connections for tightness and signs of corrosion.
  • Battery Inspection: Inspect batteries regularly for any signs of damage, leakage, or swelling. Ensure battery terminals are clean.
  • Environment: Ensure the inverter is operating within its specified temperature range (-10°C to 50°C) and in a dry, well-ventilated area.
Images depicting a quality control system, including various testing equipment and personnel working in a factory setting.

Figure 8: Quality Control System

8. Troubleshooting

This section provides solutions to common issues you might encounter.

8.1 Common Issues and Solutions

  • Inverter not turning on: Check battery connections and voltage. Ensure the battery breaker is on. Verify solar input if operating in solar-priority mode.
  • No AC output: Check AC output breaker. Verify if the inverter is in fault mode (check LCD display for error codes). Ensure battery voltage is sufficient.
  • Overload warning: Reduce the connected load. The inverter has overload protection and may shut down to prevent damage.
  • Short circuit protection activated: Disconnect all loads and check for any short circuits in the wiring. Reconnect loads one by one to identify the faulty device.
  • Battery not charging: Check solar panel connections and ensure they are receiving sunlight. Verify AC input if charging from utility/generator. Check charging current settings.
  • Wi-Fi monitoring issues: Ensure the inverter's Wi-Fi module is enabled and within range of your router. Check your network connection and app settings.

9. User Tips

  • Product Selection: If you are unsure about the specific inverter model or configuration for your needs, it is recommended to consult with the seller or a qualified solar professional. Provide details about your power requirements and existing setup for accurate recommendations.
  • Battery Management: Utilize the smart battery charger design and configurable settings to optimize your battery's performance and lifespan. Regularly monitor battery health via the LCD or Wi-Fi app.

10. Warranty and Support

The SUOER VMS-V-2.2K Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase.

Quality Assurance: The manufacturer ensures quality through a rigorous process including pre-production samples before mass production and a final inspection before packing.

For technical support, warranty claims, or any inquiries, please contact your point of purchase or the manufacturer directly. Ensure you have your model number and purchase details available when contacting support.

Certificates of Conformity for various standards, including CE and RoHS, indicating product compliance.

Figure 9: Product Certifications

© 2025 SUOER. All rights reserved.