1. Introduction
This meter is a portable smart meter that intelligently recognizes DC voltage, AC voltage, resistance, on-off buzzer, and automatically switches to the corresponding range. Ordinary users can easily measure various electrical parameters without professional knowledge of physics.
The large-screen LCD display and 4000-count display make readings more accurate. It meets the safety standards of IEC 61010 for 600V CAT III and pollution degree 2.

2. Safety Information
When using this meter, the user must comply with all standard safety regulations regarding protection against electric shocks and preventing the misuse of the instrument's safety procedures. To ensure personal safety, always use the provided test leads, check them before use, and ensure they are intact.
Safety Symbols
| Symbol | Description |
|---|---|
| ⚠ | Warning |
| ~ | AC (alternating current) |
| ⎓ | DC (direct current) |
| ⏚ | Ground |
| ⎔ | Double insulation |
| CE | European Union Standard |
| ⌁ | High voltage warning |
| CAT III | Category III overvoltage protection |
Safety Notices:
- The use of meter instruments near devices with large electromagnetic disturbances may be unstable and may even cause large errors.
- Do not use when the appearance of the meter or the test pen is broken.
- If the meter is not used correctly, the safety functions provided by the meter may fail.
- Care must be taken when working around bare conductors or buses.
- Do not use this instrument near explosive gas vapor or dust.
- The correct input function must be used to measure the range.
- The input value must not exceed the limit of the input value specified for each range to prevent damage to the instrument.
- Do not touch the unused input when the instrument is connected to the circuit under test.
- When the measured voltage exceeds 60 VDC or 30 VAC, use caution to prevent electric shock.
- When measuring with a test pen, place your finger behind the guard ring of the test.
- Before converting the range, it must be ensured that the test pens have left the circuit under test.
- When measuring voltages, do not exceed 600 V. Do not use the instrument if the instrument case or part of the case has been removed.
3. Specifications
| Function | Range | Resolution | Accuracy | Note |
|---|---|---|---|---|
| DC Voltage (DCV) | 0.8V-600V | 0.001V | ± (0.8%+5) | Min Input Voltage: 0.8V, Max Input Voltage: 600V, Resistor Impedance: 10M |
| AC Voltage (ACV) | 1V-600V | 0.001V | ± (1.0%+5) | Min Input Voltage: 1V, Max Input Voltage: 600V, Resistor Impedance: 10M |
| Resistance | 0Ω-40MΩ | 1Ω | ± (1.0%+10) | Protection: 600V AC/DC |
| Max Display | 4000 counts | |||
| Auto Power-off | ✔ | No operation for 5 minutes | ||
| Backlight | ✔ | Turns off after 30 seconds | ||
| Illumination (Flashlight) | ✔ | Turns off after 30 seconds | ||
| Buzzer | ✔ | Protection: 600V AC/DC | ||
| Buzzer Indicator | ✔ | |||
| NCV (Non-Contact Voltage) | ✔ | "----" refers to change from strong to weak | ||
| NCV Indicator | ✔ | |||
| True RMS | ✔ | 45Hz-2KHz | ||
| Low Battery Indicator | ✔ |
General Specifications:
- Operating Temperature: 0 - 40 ℃ (< 80% RH)
- Storage Temperature: -10 - 60 ℃ (< 70% RH, remove battery)
- Test/Calibrate Surrounding Temperature: 20 ℃ ± 2 ℃
- Max Voltage between Measurement End and Ground: 600V
- Conversion Rate: About 3s/second
- Overload: 'OL' displayed
- Input Polarity Indicator: '-' shown automatically
- Battery: 2 x AAA 1.5V (not included)
- Dimensions: 123mm (L) x 61mm (W) x 24mm (H)
- Weight: About 78g (battery excluded)
4. Setup
4.1. Battery Installation
The instrument uses two AAA 1.5V batteries as the power supply. The battery must be properly installed in the battery compartment of the meter.
To replace the battery:
- Turn off the instrument and pull all test leads out of the input sockets.
- Use a screwdriver to loosen the screws fixing the battery cover.
- Remove the battery cover and take out the old batteries.
- Replace with new 2 x AAA 1.5V batteries.
- Install the battery cover and close the screws.
When the low voltage symbol (⎕) appears, replace the battery immediately. Insufficient battery power can cause incorrect readings, potentially leading to electric shock or personal injury.

5. Operating Instructions
5.1. Power On/Off
Press the red power button (⏻) to turn the multimeter on. The display will show 'Auto'. To turn off, long press the power button again. The device will automatically power off if there is no operation within 5 minutes.
5.2. Backlight and Flashlight
The meter has backlight and illumination functions for convenient reading in dark situations. To operate:
- Backlight: Short press the */⌂ key to turn on the backlight. Short press again to turn it off. It turns off automatically if there is no operation for 30 seconds.
- Flashlight: Long press the */⌂ key to turn on both the flashlight and backlight. Short press the key again to turn off the flashlight. It turns off automatically if there is no operation for 30 seconds.

5.3. AC/DC Voltage and Resistance Measurement
- Connect the black test lead to the COM jack and the red test lead to the V/Ω jack.
- Turn on the meter by pressing the power key.
- Connect the test leads to the circuit to be tested. The meter will automatically judge ACV, DCV, or resistance.
- For resistance, if the circuit under test is not greater than about 50 ohms, the indicator light will turn on and the buzzer will sound continuously.
- The screen also shows the polarity of the red test lead as well as the surrounding temperature when DCV is measured.


5.4. NCV (Non-Contact Voltage) Detection
The NCV function allows for non-contact voltage detection, minimizing unnecessary injuries.
- Turn on the meter by pressing the power key.
- Press the HOLD NCV button constantly and test when "EF" is shown on the screen.
- The NCV indicator flashes with a buzzer when there is voltage on the live wire. The screen shows the strength of the magnetic field, indicated by "----" changing from strong to weak, according to the signal strength.

5.5. Voice Broadcast Function (C1 Model Only)
The NJTY C1 model features a voice announcement function. When the measured value stabilizes, the instrument will audibly read out the data, making it convenient to work without constantly looking at the screen, especially in bright light conditions.

5.6. Data Hold
The 'HOLD' function is available in valid mode. Press the HOLD NCV button briefly to hold the current reading on the display. Press it again to release.
5.7. Auto Power Off
After about 5 minutes of inactivity, the multimeter will give audible voice prompts and automatically power off to conserve battery life.

6. Maintenance
- When opening the instrument case or removing the battery cover, always pull out the test leads first.
- Only specified replacement parts must be used to service the meter.
- Before opening the meter, all relevant power must be disconnected. Ensure no static electricity is present to avoid damage.
- Instrument components, calibration, and maintenance operations should only be performed by professionals.
- When opening the instrument housing, be aware that some capacitance within the instrument may retain dangerous voltages even after the instrument is turned off.
- If any abnormality is observed, stop use immediately and send for repair. Do not use until inspected and qualified.
- When not in use for a long time, remove the battery and avoid storing in high temperature and humidity.
7. Troubleshooting
- No display/Power issues: Ensure batteries are correctly installed and have sufficient charge. Replace if the low battery indicator is on.
- Inaccurate readings: Check test leads for damage. Ensure correct measurement function is selected (though auto-ranging helps). Avoid strong electromagnetic interference.
- NCV not working: Ensure the device is powered on and the NCV function is activated. Note that external factors like flashlights or radar can cause NCV flashes.
- No voice broadcast (C1 model): Ensure the value is stable for the voice function to activate.
8. User Tips
- Always prioritize safety. Double-check connections and ensure circuits are de-energized before testing resistance or continuity.
- Utilize the backlight and flashlight in dimly lit areas for clear readings and improved safety.
- For the C1 model, listen for the voice broadcast function when working in awkward positions or when the display is hard to see.
- The auto-ranging feature simplifies operation, but always be aware of the maximum input limits for each function.
- Keep the multimeter clean and dry to ensure its longevity and accurate performance.
9. Warranty and Support
For detailed warranty information or technical support, please refer to the official documentation provided with your purchase. A user manual in PDF format is available for download: User manual (PDF).