JUNCTEK KH-F Series

Contents

JUNCTEK KH-F Series Battery Monitor User Manual

Models: KH110F, KH140F, KH160F

1. Product Overview

The JUNCTEK KH-F series is a multi-function voltage and current meter designed for comprehensive battery monitoring. It is compatible with various battery types, including lead-acid, ternary lithium, and lithium iron phosphate batteries, provided the battery voltage is within the measuring range.

The system consists of a display module, a measuring module, and a current sampler (shunt).

JUNCTEK KH-F Series Battery Monitor components

Figure 1: Overview of Display Module, Measuring Module, and Samplers (100A, 400A, 600A)

Key Features:

  • High-definition color screen display
  • Bidirectional monitoring of charging and discharging current
  • Real-time capacity monitoring
  • Voltage/Current (V/A) curves
  • Automatic alarm functions
  • Mobile APP control via Bluetooth
  • Intelligent brightness adjustment
  • Firmware update capabilities
Key features of the KH-F Battery Monitor

Figure 2: Visual representation of key features

2. Package Contents

Please verify that all items listed below are included in your package:

Shipping list for JUNCTEK KH-F Battery Monitor

Figure 3: Detailed view of all included components

  1. Display Module *1
  2. Measuring Module *1
  3. Sampler *1 (Current rating depends on model: 100A, 400A, or 600A)
  4. Temperature Sensor *1
  5. 3P Terminal *1
  6. 5m Communication Cable *1
  7. 3P Connection Cable *1
  8. 4P Connection Cable *1

3. Setup and Wiring

Proper wiring is essential for accurate measurement and safe operation. Refer to the diagrams below for connection instructions.

3.1 Sampler Installation

The sampler (current sensor) features a newly designed case for convenient fixing and good insulation protection. The shunt and screws are made of pure copper for good conductivity, low heating, and low power consumption.

Exploded view of the sampler with new case

Figure 4: Sampler (Current Sensor) with new case design

Pure copper screw shunt components

Figure 5: Components of the Pure Copper Screw Shunt

3.2 Wiring Diagrams

There are two primary wiring methods: self-powered and external power supply. An external power supply with relay control is also possible for protection functions.

Self-Powered and External Power Supply Wiring Diagrams

Figure 6: Self-Powered and External Power Supply Wiring Diagrams

Self-Powered Wiring Diagram:

  • Connect the measuring module directly to the battery and load/charger as shown.
  • The display module connects to the measuring module via the RS-485 Link.

External Power Supply Wiring Diagram:

  • An external DC 10-80V power supply is used to power the measuring module.
  • Connect the measuring module to the battery and load/charger as shown.
  • The display module connects to the measuring module via the RS-485 Link.

External Power Supply Wiring Diagram (Relay Control):

External Power Supply Wiring Diagram with Relay Control

Figure 7: External Power Supply Wiring Diagram with Relay Control

  • This setup allows the instrument to disconnect the circuit via a relay when protection limits are exceeded.
  • The external power supply voltage for the relay should match its working voltage (e.g., 12V or 24V).
  • The relay needs to be purchased separately.

4. Operating Instructions

4.1 Display Interface

The display module provides real-time monitoring of various battery parameters:

Display module showing various parameters

Figure 8: Main display interface

  • Voltage (V): Current battery voltage.
  • Current (A): Current charging/discharging current.
  • Power (W): Real-time power consumption/generation.
  • Capacity (Ah): Remaining battery capacity.
  • Percentage (%): State of charge.
  • Temperature (°C): Battery temperature (requires temperature sensor).
  • Time Left: Estimated remaining time for charging/discharging.
  • Record: Data recording status.

4.2 Button Functions

The display module features several buttons for navigation and settings:

  • SET: Enters the settings menu.
  • Up Arrow: Navigates up or increases values in settings.
  • Down Arrow: Navigates down or decreases values in settings.
  • OK: Confirms selections or exits menus.

4.3 Settings Interface

The new settings interface is designed for ease of use, allowing configuration of various parameters.

New settings interface screens

Figure 9: Examples of the new settings interface

4.4 Mobile APP Control

The device supports Bluetooth connection for mobile APP control, offering enhanced functionality:

Mobile APP interface for settings, main view, and curves

Figure 10: Mobile APP Control interface

  • Real-time Data: View all relevant data on your mobile device.
  • Curve Function: Display real-time and historical curves of voltage and current.
  • Settings: Adjust all functions and parameters remotely.
  • Data Export: Supports exporting historical data for analysis.
  • Firmware Upgrade: The APP provides capabilities for firmware upgrades.

5. Protection Functions and Alarms

The instrument can be configured with various protection settings to prevent damage to electrical equipment.

Comprehensive protection shields

Figure 11: Visual representation of comprehensive protection features

When a parameter value exceeds the preset protection limit, the instrument will activate the protection function:

  1. An alarm sound will activate, accompanied by a pop-up reminder on the display.
  2. The circuit will be disconnected through a relay (if connected) to protect the instrument and connected equipment from damage.
Alarm reminder pop-up on display

Figure 12: Alarm reminder for Over Voltage Protection (OVP)

The following protection types can be set:

AbbreviationDescription
OVPOver Voltage Protection
OTPOver Temperature Protection
LVPLow Voltage Protection
OPPOver Power Protection
OCPOvercurrent Protection for Discharging
NCPOvercurrent Protection for Charging

The protection recovery time and delay protection time can also be configured to suit various applications.

6. Specifications

The JUNCTEK KH-F series offers different models based on current rating.

General Specifications:

  • Voltage Measurement Range: 0-120V DC
  • Battery Compatibility: Lead-acid, Ternary Lithium, Lithium Iron Phosphate, and other battery types within the voltage range.
  • DIY Supplies: Electrical
  • Battery Included: No
  • High-concerned chemical: None
  • Origin: Mainland China

Model-Specific Current Ratings and Shunts:

Model NumberMax Current MeasurementActual Shunt Rating
KH110F100A200A
KH140F400A500A
KH160F600A750A
Note on shunt ratings for KH-F models

Figure 13: Shunt rating details for different models

Dimensions:

Dimensions of display module and measuring module

Figure 14: Dimensions of Display Module and Measuring Module

Dimensions of KH110F, KH140F, KH160F samplers

Figure 15: Dimensions of KH110F, KH140F, and KH160F Samplers

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the display and modules. Avoid using harsh chemicals or abrasive materials.
  • Storage: Store the device in a dry, cool environment away from direct sunlight and extreme temperatures.
  • Firmware Updates: Regularly check for and apply firmware updates via the mobile APP to ensure optimal performance and access to new features.

8. Troubleshooting

If you encounter issues with your JUNCTEK KH-F Battery Monitor, consider the following:

  • No Display/Power: Ensure all power connections are secure and the external power supply (if used) is providing the correct voltage.
  • Inaccurate Readings: Double-check all wiring according to the diagrams. Ensure the shunt is correctly installed and the communication cable is properly connected. Verify that the correct shunt rating is selected in the device settings if applicable.
  • Alarm Triggered: Identify the type of alarm (e.g., OVP, LVP) from the display. Check the battery voltage, current, or temperature against the set protection limits. Address the underlying issue (e.g., overcharging, excessive discharge, overheating).
  • APP Connectivity Issues: Ensure Bluetooth is enabled on your mobile device and the monitor. Try restarting both the monitor and your mobile device. Ensure the APP is up to date.
  • Relay Not Disconnecting: Verify the relay is correctly wired and its working voltage matches the external power supply. Ensure the protection settings are enabled and configured correctly in the monitor.

9. Warranty and Support

For warranty information and technical support, please refer to the documentation provided by your seller or contact the seller directly. Keep your purchase receipt for any warranty claims.