1. Introduction

The FNIRSI GD-02 is a high-performance combustible gas detector designed for accurate detection of methane, propane, and isobutane concentrations in various environments. Featuring a color screen, flexible probe, and multiple alarm types, it provides reliable safety monitoring for both home and industrial applications. This manual provides detailed instructions for the proper use and maintenance of your GD-02 detector.

FNIRSI GD-02 Combustible Gas Detector with 50000PPM range, showing 3 types of alarms, curve recording, and data record.
FNIRSI GD-02 Combustible Gas Detector overview.

2. Key Features

  • High Precision Detection: Accurately detects methane, propane, and isobutane with a measurement range of 0~50000ppm (Methane) or 0~100%LEL.
  • 2.0-inch IPS Color Screen: Provides clear display of gas concentration, temperature, and humidity readings.
  • Flexible Probe: Equipped with a 36cm flexible probe for reaching confined spaces.
  • Multiple Alarm Types: Features visual, audible, and vibration alarms for immediate alert.
  • Curve Recording & Data Storage: Allows for easy visualization of gas concentration trends and logging of alarm data for review.
  • Fast Response Time: Warm-up time of approximately 15-16 seconds, response time (T90) less than 5 seconds.
  • Temperature Unit Switching: Easily switch between Celsius (°C) and Fahrenheit (°F).
  • Built-in Flashlight & Backlight: Ensures clear visibility in dark environments.
  • Rechargeable Lithium Battery: Integrated 1500mAh battery with auto-shutdown function for extended usage.
  • Firmware Upgrades: Supports easy firmware updates via computer connection.
Nine advantages of the GD-02 detector: 0-50000PPM detect, 36cm flexible probe, 3 types alarms, curve recording, data record & hold, 2 IPS color screen, rechargeable lithium battery, °F & °C switching, flashlight & backlight.
Overview of GD-02 key features.

3. Specifications

ParameterSpecification
Model ParametersGD-02
Screen Material2.0-inch Color Screen
Detectable GasesMethane, Propane, Isobutane
Measurement Range (PPM)0~50000ppm (Methane)
Measurement Range (%LEL)0~100 (A%LEL)
Resolution1ppm/1%LEL
Operating Temperature-10~55°C
Warm-up TimeAround 15-16 seconds
Response Time (T90)<5s
Recovery Time (T10)<10s
Service Life>3 years
Sampling Time≈0.5s
Size≈63×28×139 (+360)mm (with probe)
Product Weight≈296g
Battery IncludedYes (1500mAh Lithium Battery)
Is Smart DeviceNo
DIY SuppliesElectrical
OriginMainland China
CertificationCE, WEEE
Table of product parameters for the GD-02 gas detector.
Detailed product parameters.

4. Package Contents

Ensure all items are present upon unboxing:

  • GD-02 Combustible Gas Leak Detector (x1)
  • Storage Bag (x1)
  • Data Cable (x1)
  • User Guide (x1)
  • Packing Box (x1)
Image showing the GD-02 detector, storage bag, data cable, user guide, and packing box.
Contents included in the GD-02 package.

5. Setup

  1. Unboxing: Carefully remove all components from the packing box.
  2. Initial Charge: Connect the GD-02 to a power source using the provided data cable. The device has a built-in 1500mAh rechargeable lithium battery. Ensure it is fully charged before first use.
  3. Power On: Press and hold the power button (usually indicated by a power symbol) to turn on the device.
  4. Warm-up: Allow approximately 15-16 seconds for the device to warm up and stabilize before taking measurements.

6. Operating Instructions

6.1 Basic Operation

  • Power On/Off: Press and hold the power button to turn the device on or off.
  • Gas Detection: Once powered on and warmed up, the device will automatically begin detecting combustible gases. Position the 36cm flexible probe near the suspected leak source.
  • Reading Display: Gas concentration will be displayed on the 2.0-inch IPS color screen in PPM or %LEL, along with environmental temperature and humidity.
GD-02 detector with 36cm flexible probe, showing <0.5s response time and 1ppm/1%LEL resolution.
Utilizing the flexible probe for swift gas detection.

6.2 Alarm System

The GD-02 features three types of alarms to alert users to gas leaks:

  • Visual Alarm: The screen will display a warning indicator.
  • Audible Alarm: A buzzer will sound.
  • Vibration Alarm: The device will vibrate.

These alarms can be configured in the general settings.

Image showing visual, audible, and vibration alarm indicators on the GD-02 screen.
Visual, audible, and vibration alarm types.

6.3 Data Visualization and Recording

  • Curve Recording: The device can display gas concentration trends over time in a curve graph on the screen, allowing for easy visualization of changes.
  • Data Record: The GD-02 logs alarm data, storing over 30 sets of records for later review and analysis.
Smart Curve Data Visualization on the GD-02 screen, showing gas concentration trends.
Smart Curve Data Visualization for trend analysis.

6.4 Settings and Customization

The GD-02 offers various settings to customize its operation:

  • General Settings:
    • Alarm Settings: Enable/disable indicator, vibrator, and buzzer.
    • Threshold Settings: Adjust high and low alarm thresholds numerically.
    • Language Switching: Select between Chinese and English.
    • Style Switching: Choose between dark and light display modes.
    • Unit Switching: Toggle between PPM and %LEL for gas concentration, and °C and °F for temperature.
  • System Settings:
    • Date and Time Adjustment: Set the current date and time.
    • Sleep Settings: Configure auto-sleep duration to conserve battery.
    • Brightness Settings: Adjust screen brightness.
    • Factory Reset: Restore default settings.
    • Volume Settings: Adjust alarm volume.
GD-02 screen showing 2-inch IPS color display with temperature in Celsius and Fahrenheit, and gas concentration in PPM and %LEL.
2-inch IPS Color Screen for accurate readings and unit switching.

7. Maintenance

  • Cleaning: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Battery Care: Recharge the device regularly to maintain battery health. Avoid fully discharging the battery for extended periods.
  • Storage: Store the GD-02 in its provided storage bag in a cool, dry place when not in use.
  • Firmware Updates: Periodically check for and apply firmware updates to ensure optimal performance and new features. Connect the device to a computer using the data cable for updates.
Image showing the internal 1500mAh battery of the GD-02 and highlighting the auto-shutdown feature.
1500mAh battery with auto-shutdown for energy conservation.
GD-02 connected to a computer for firmware upgrade.
Easy firmware upgrades via computer.

8. Troubleshooting

If you encounter issues with your GD-02 detector, consider the following:

  • Device Not Powering On:
    • Ensure the battery is charged. Connect to a power source and allow it to charge for at least 30 minutes.
    • Verify the power button is pressed and held correctly.
  • Inaccurate Readings/No Detection:
    • Ensure the device has completed its warm-up period (approx. 15-16 seconds).
    • Check if the probe is positioned correctly near the suspected gas source.
    • Ensure the sensor is clean and unobstructed.
    • Perform a factory reset if readings seem consistently off (refer to System Settings).
  • Alarms Not Functioning:
    • Check alarm settings in the General Settings menu to ensure visual, audible, and vibration alarms are enabled.
    • Verify alarm thresholds are set appropriately for your detection needs.
  • Screen Issues:
    • Adjust screen brightness in System Settings.
    • If the screen is unresponsive or frozen, try a soft reset by holding the power button until it turns off, then restart.

9. User Tips

  • Environmental Adaptation: The GD-02 has excellent anti-interference ability and is designed to adapt to most environments. However, for critical measurements, ensure the area is well-ventilated and free from other strong odors or chemicals that might interfere with gas detection.
  • Threshold Customization: Utilize the flexible gas concentration threshold settings to tailor the alarm sensitivity to your specific application, whether for home safety or industrial monitoring.
  • Regular Data Review: Regularly review the stored alarm records and curve recordings to identify patterns or potential intermittent leak issues that might not be immediately obvious.
  • Probe Handling: The 36cm flexible probe is designed for versatility. Handle it with care to avoid damage, especially when maneuvering into tight spaces.
Image showing wide application areas for the GD-02: Gas Pipeline, Car Repair, Industrial Leak Detection, Household Appliances.
Wide application of the GD-02 detector.

10. Warranty and Support

FNIRSI products undergo strict quality inspection. For any questions, assistance, or support regarding your GD-02 detector, please refer to the contact information provided in the original packaging or on the official FNIRSI website. Keep your purchase receipt for warranty purposes.

Product warranty and quality assurance information, stating strict quality inspection and contact for help.
FNIRSI product quality assurance.

FNIRSI GD-02 Portable Combustible Gas Detector: Unboxing & Feature Demo

FNIRSI GD-02 Portable Combustible Gas Detector: Unboxing & Feature Demo

0:45 • 606×1080 • feature_demo
FNIRSI GD-02 Portable Combustible Gas Detector: Unboxing & Feature Demo

FNIRSI GD-02 Portable Combustible Gas Detector: Unboxing & Feature Demo

0:45 • 404×720 • feature_demo

Related Documents - GD-02

Preview FNIRSI GD-02 Color Screen Combustible Gas Detector User Manual
Comprehensive user manual for the FNIRSI GD-02 color screen combustible gas detector, covering safety, product overview, technical specifications, operation, troubleshooting, maintenance, and warranty information.
Preview FNIRSI WD-02 Wall Detector Instruction Manual | Find Studs, Wires, Pipes
Comprehensive instruction manual for the FNIRSI WD-02 Wall Detector. Learn how to detect metal studs, live AC wires, and foreign objects in walls, ceilings, and floors with detailed operating instructions, specifications, and troubleshooting tips.
Preview FNIRSI WD-02 Wall Detector Instruction Manual: Detect Studs, Wires, and Metal
This FNIRSI WD-02 Wall Detector instruction manual provides comprehensive guidance on detecting metal objects, foreign objects (like wooden studs), and live AC cables. Includes detailed operating instructions, specifications, and safety precautions for accurate wall scanning.
Preview FNIRSI WD-01 Wall Detector User Manual
User manual for the FNIRSI WD-01 Wall Detector, providing detailed instructions on its functions, specifications, detection types (metal, wood, live cables), operation, and maintenance.
Preview FNIRSI WD-02 Wall Detector Instruction Manual - Detect Studs, Metal, and Wires
Comprehensive instruction manual for the FNIRSI WD-02 Wall Detector. Learn how to efficiently detect studs, metal objects, and live wires within walls, ceilings, and floors. Features multi-language support.
Preview FNIRSI WD-02 墙体探测仪使用说明书 - Wall Detector Instruction Manual
FNIRSI WD-02 墙体探测仪用户手册,提供在墙壁、天花板和地板中探测金属物体、异物(如木梁)和带电电缆的详细说明。包含产品规格、操作指南、界面解析及维护信息,支持中文、英文、俄文和葡萄牙文。