1. Product Overview
The JIKONG V19 Smart Battery Management System (BMS) is designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, and over-temperature protection, along with coulomb metering, Bluetooth communication, and host computer monitoring capabilities. This BMS is suitable for lithium iron phosphate (LiFePO4), ternary lithium (Li-ion), and lithium titanate (LTO) battery types.
The protection board utilizes energy transfer active balancing technology, achieving a maximum continuous balance current of 1A/2A. This high-current active equalization technology ensures battery consistency, extends battery range, and delays battery aging. It features a mobile APP for Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. The compact design, ease of operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.
2. Key Features
- LED Bluetooth status indicator
- APP Bluetooth remote operation
- Battery capacity calculation
- Supports PC operations
- High precision voltage acquisition (±3mV)
- High precision current acquisition
- Support information screen display
- Accurate time logging
- Support RS485 communication
- Support CAN communication
- Support heating function
- Alarm dry contact function
- Discharge precharge function
- Charge overcurrent protection
- Charge overvoltage protection
- Charge over temperature protection
- Low temperature protection during charge
- Discharge overcurrent protection
- Discharge undervoltage protection
- Discharge over temperature protection
- Short circuit protection
- Battery parallel current limiting function

Image description: JIKONG V19 JK-PB2A16S20P Smart BMS highlighting key specifications like 8S-16S, 200A charge/discharge, 2A balancing current, and support for Li-ion/Lifepo4/LTO battery types.
3. Specifications
3.1. General Parameters
| Serial Number | Project | Argument | Unit |
|---|---|---|---|
| 1 | Supply voltage | 20-70 | V |
| 2 | Standby power consumption | 12 | mW |
| 3 | Operating power consumption | 1100 | mW |
| 4 | Operating temperature | -30-70 | °C |
| 5 | Maximum number of collection strings | 16 | S |
| 6 | Maximum balancing current | 2 | A |
| 7 | Maximum charging current | 10P: 100, 15P: 150, 20P: 200 | A |
| 8 | Maximum discharge current | 10P: 100, 15P: 150, 20P: 200 | A |
| 9 | Maximum instantaneous current | 10P: 200, 15P: 300, 20P: 400 | A |
| 10 | Maximum internal loop resistance | 10P: 1, 15P: 0.45, 20P: 0.35 | mΩ |
| 11 | Protective plate size | 300*100*24 | mm |
| 12 | Finished weight | 1000 | g |
3.2. Default Parameters
| Parameter | Li-ion Default | LiFePO4 Default | LTO Default | Unit |
|---|---|---|---|---|
| Balancing initial voltage | 3 | 3 | 2 | V |
| Maximum balancing current | 2 | 2 | 2 | A |
| Unit overcharge voltage | 4.2 | 3.6 | 2.7 | V |
| Single overcharge protection recovery | 4.17 | 3.54 | 2.64 | V |
| Monomer undervoltage protection | 2.82 | 2.6 | 1.8 | V |
| Single undervoltage protection recovery | 2.85 | 2.65 | 1.85 | V |
| Automatic shutdown voltage | 2.8 | 2.5 | 1.7 | V |
| SOC-0% voltage | 2.9 | 2.6 | 1.85 | V |
| SOC-100% voltage | 4.18 | 3.5 | 2.65 | V |
| Trigger balancing differential pressure | 0.01 | 0.01 | 0.01 | V |
| Charging overcurrent protection delay | 3 | 3 | 3 | S |
| Charge overcurrent protection release time | 60 | 60 | 60 | S |
| Discharge overcurrent protection delay | 300 | 300 | 300 | S |
| Discharge overcurrent protection release time | 60 | 60 | 60 | S |
| Short-circuit protection delay | 5 | 5 | 5 | uS |
| Short circuit protection release time | 30 | 30 | 30 | S |
| Charging overtemperature protection temperature | 70 | 70 | 70 | °C |
| Charge overtemperature restore temperature | 60 | 60 | 60 | °C |
| Discharge overtemperature protection temperature | 70 | 70 | 70 | °C |
| Discharge overtemperature recovery temperature | 60 | 60 | 60 | °C |
| Charging low temperature protection temperature | -20 | -20 | -20 | °C |
| Charge low temperature to restore temperature | -10 | -10 | -10 | °C |
| MOS Overtemperature protection temperature | 100 | 100 | 100 | °C |
| MOS Overtemperature protection recovery temperature | 80 | 80 | 80 | °C |
| Device address | 0 | 0 | 0 | / |
| Discharge precharge time | 5 | 5 | 5 | S |
3.3. Product Dimensions
The dimensions of the JK-PB1/2A16S-10/15/20P series protection board are 300mm × 100mm × 24mm. Refer to the diagram below for detailed measurements.

Image description: Diagram showing the dimensions of the JK-PB1/2A16S-10/15/20P series protection board, measuring 300mm x 100mm x 24mm.
4. Installation and Wiring
4.1. Safety Precautions
- Ensure all connections are secure and correct before powering on the BMS.
- Verify that the balance cables are properly connected.
- Confirm that the P- and B- connections are correct.
- Securely fix the protection board to the battery pack to prevent movement or damage.
- Incorrect wiring or loose connections can lead to abnormal operation or severe damage.
4.2. Wiring Method
The JK-PB1/2A16S-10/15/20P series protection board is suitable for 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in the battery pack. Always refer to the detailed wiring diagrams provided.

Image description: Wiring diagram for the JIKONG BMS, showing connections for 16-string and 8-string cells, including B+, P-, charger, inverter, and display/switch connections. Note: There are two B8 cables; only the first B8 line needs to be connected. The second B8 cable does not need to be connected.
4.3. Interface Definitions
The BMS features various connectors for different functionalities. Understanding these interfaces is crucial for proper installation and operation.
Main Board Connectors (P1-P11)
| Connector | Interface Name | Pin Number | Name | Definition |
|---|---|---|---|---|
| P1 | Interface board interface | Connects to the interface board | ||
| P4 | URAT display interface | 1 | K- | Activation signal negative electrode |
| 2 | K+ | Activate the positive signal | ||
| 3 | GND | Negative terminal | ||
| 4 | RX | UART RX, 5V | ||
| 5 | TX | UART TX, 5V | ||
| 6 | VCC | Display power output | ||
| P5 | Display interface | 1 | VCC | Display power output |
| 2 | A | Display RS485-A (negative signal) | ||
| 3 | B | Display RS485-B (positive signal) | ||
| 4 | GND | Negative terminal | ||
| 5 | K+ | Activation signal positive electrode | ||
| 6 | K- | Activation signal negative electrode | ||
| P6 | Acquisition interface | 1 | NT1 | Connect NTC1 temperature probe |
| 2 | GND | Connect NTC1 temperature probe | ||
| 3 | B0 | Total negative battery | ||
| 4 | B1 | The first battery positive | ||
| 5 | B2 | The second battery positive | ||
| 6 | B3 | The third battery positive | ||
| 7 | B4 | The fourth battery positive | ||
| P7 | Acquisition interface (Blue) | 1 | NTC2 | Connect NTC2 temperature probe |
| 2 | GND | Connect NTC2 temperature probe | ||
| P8 | Acquisition interface (Red) | 1 | NT3 | Connect NTC3 temperature probe |
| 2 | GND | Connect NTC3 temperature probe | ||
| 3 | B8 | Reserved pin | ||
| 4 | B9 | The ninth battery positive | ||
| 5 | B10 | The tenth battery positive | ||
| 6 | B11 | The eleventh battery positive | ||
| 7 | B12 | The twelfth battery positive | ||
| P9 | Acquisition interface (Yellow) | 1 | NT4 | Connect NTC4 temperature probe |
| 2 | GND | Connect NTC4 temperature probe | ||
| 3 | B13 | The thirteenth battery positive | ||
| 4 | B14 | The fourteenth battery positive | ||
| 5 | B15 | The fifteenth battery positive | ||
| 6 | B16 | The sixteenth battery positive | ||
| P10 | Heating interface (M3 screw) | 1 | HT- | Heater element negative electrode |
| P11 | Power input (M3 screw) | 1 | B+ | The power input is positive |
| D1 | Bluetooth connection indicator | Steady on when connected, blinking when disconnected. | ||
| P- | Connect to external load or negative terminal of charger (M6 screw) | |||
| B- | Connect to the negative battery terminal (M6 screw) |
Interface Board Connectors
The interface board provides additional connectivity for communication and control.

Image description: Detailed diagram of the BMS interface board, showing various ports like RS485, CAN, UART, RS232, and the dial switch for address setting.
| Interface | Pin Number | Pin Definition | Remark |
|---|---|---|---|
| Dry Contact | 1 | COM1 | |
| 2 | S1 | ||
| 3 | COM2 | ||
| 4 | S2 | ||
| CAN and RS485-1 | 1, 8 | RS485-B1 | |
| 2, 7 | RS485-A1 | ||
| 3, 6 | GND | ||
| 4 | CANH | ||
| 5 | CANL | ||
| 7 | GND | ||
| RS485-2 | 1 | RS485-B2 | |
| 2 | RS485-A2 | ||
| 3 | GND | ||
| 4 | NC |
5. Operation
5.1. Device Activation
The BMS does not have a power-on control switch. It is designed for charging activation. After the battery assembly is complete, connect a charger (with voltage 2V higher than battery voltage) to activate the BMS. Alternatively, if you have a display screen or button, simply insert the cable into the display interface and press the button to activate.
5.2. Active Equalization
The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells. Users can set the balance trigger pressure difference (mV) in the APP. When the difference between any two battery strings exceeds this value, balancing automatically activates. The default balance current is 1A/2A, adjustable via the APP based on battery capacity. The balancing function can be disabled via the APP if not needed.
5.3. Heating Function
The BMS includes a heating function to warm the battery at low temperatures, preventing charging/discharging issues due to reduced battery activity. The heating current is 10A. Users can control this function via the APP. It is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection against thermal runaway.
5.4. Dry Contact Function
Two dry contacts are provided to control external devices like alarms or fans. When the BMS detects over-temperature, overcharge, or over-discharge, the dry contact can trigger an alarm or activate cooling fans. Users can select two trigger conditions via the APP and configure them as needed.

Image description: Diagram illustrating the wiring principle for connecting a dry contact to external alarm equipment, showing a buzzer and DC power supply.
5.5. Discharge Precharge Function
The BMS includes a discharge pre-charging function with a default time of 5 seconds. This function can be enabled or disabled via the APP. Setting the precharge time to 0 disables the function.
5.6. Communication Function (Parallel Operation)
The BMS supports CAN and RS485 communications. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications. Two RS485 communication interfaces are available: RS485-1 for communication with inverters and other settings, and RS485-2 for connecting battery packs in parallel and communicating with a host computer. The default baud rate for RS485-2 is 115200. The BMS address (0-15) can be set using a DIP switch for parallel operation, with address 0 typically being the host.

Image description: Diagram showing multiple JIKONG BMS units connected in parallel for monitoring via a host computer, illustrating the RS485-2 daisy-chain connection.
5.7. APP and PC Software Operation
The JIKONG BMS can be monitored and configured using a mobile application (Android 7+ and iOS) or PC software. Download the mobile APP by scanning the QR code below. The APP and PC software provide multi-screen displays for real-time data, settings, and fault logging.

Image description: QR code for downloading the JIKONG BMS mobile application, compatible with Android (version 7 minimum) and iOS.

Image description: Screenshots of the JIKONG BMS mobile app and PC software, demonstrating multi-screen display and data connection for monitoring battery parameters like voltage, current, temperature, and SOC.
6. Protection Functions and Troubleshooting
The JIKONG BMS is equipped with multiple protection mechanisms to ensure battery safety and longevity. These protections are configurable via the APP or PC software.
6.1. Overcharge Protection
The BMS protects against overcharging by monitoring individual cell voltages. If any cell voltage exceeds the set overcharge protection voltage, the BMS will stop charging. Charging resumes when all cell voltages drop below the overcharge recovery voltage.
6.2. Undervoltage Protection
To prevent over-discharge, the BMS monitors cell voltages during discharge. If any cell voltage falls below the undervoltage protection threshold, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the undervoltage recovery voltage. The BMS also features an automatic shutdown voltage, below which it will shut down completely to protect the cells.
6.3. Overcurrent Protection (Charge/Discharge)
The BMS provides protection against excessive charging and discharging currents. Users can set continuous current limits, overcurrent delay times, and recovery times via the APP. If the current exceeds the set limit for the specified delay, the BMS will interrupt the operation. It will resume after the recovery time.
6.4. Overtemperature Protection
The BMS monitors battery temperature during both charging and discharging. If the temperature exceeds the set over-temperature protection value, the BMS will stop the respective operation. It will resume when the temperature drops below the recovery threshold.
6.5. Low Temperature Protection
During charging, the BMS protects against low temperatures. If the battery temperature falls below the set low-temperature protection value, charging will stop. Charging resumes when the temperature rises above the recovery threshold. For extremely cold environments, using the heating function is recommended.
6.6. Short Circuit Protection
The BMS includes short-circuit protection. While the trigger current is not user-configurable, users can adjust the short-circuit protection delay and recovery time via the APP. If a short circuit occurs, the BMS will interrupt the circuit and resume operation after the recovery time. Adjusting the delay can help prevent false triggers from high inrush currents during initial connection to loads or chargers.
6.7. Emergency Switch
An emergency switch function is available. If issues like over-temperature, over-discharge, over-charge, or cell string drops occur during normal use, activating the emergency switch via the APP will enable charge and discharge for 30 minutes. This provides a temporary operational window, even if a single cell reaches automatic shutdown voltage, to prevent critical situations.
6.8. Intelligent Sleep
The intelligent sleep function allows the BMS to enter a low-power state when idle (charging/discharging current less than 1A for 26 consecutive hours) to reduce self-consumption. The BMS can be reactivated by pressing a button or connecting a charger.6.9. Charge Current Limiting
The BMS features a charge current limiting function. If the battery is overcurrent during charging, this function activates, limiting the charging current to approximately 10A to protect the battery.
6.10. LED Indicators
The interface board includes LED indicators to provide visual feedback on the BMS status and remaining battery power.
| Status | Normal, Alarm, or Protection | ON/OFF Indicator | RUN | ALM | L1 | L2 | L3 | L4 | L5 | L6 | Instructions |
|---|---|---|---|---|---|---|---|---|---|---|---|
| Power Off | Normal | OFF | |||||||||
| Balance | Normal | ON | Flicker | OFF | Based on battery display | ||||||
| Charging | Normal | ON | Flicker | OFF | Based on battery display | ||||||
| Charging | Overcurrent, over temperature, over voltage, charging failure | ON | Flicker | Flicker | Based on battery display | ||||||
| Discharge | Normal | ON | Flicker | OFF | Based on battery display | ||||||
| Discharge | Overcurrent, over temperature, under voltage, discharge failure | ON | Flicker | Flicker | Based on battery display | ||||||
| Other alarm | Password not changed, short circuit, temperature | ON | Flicker | Flicker | Based on battery display |
7. Maintenance
- Regularly check all wiring connections for tightness and corrosion.
- Keep the BMS clean and free from dust and moisture.
- Monitor battery parameters via the APP or PC software for any unusual readings.
- Ensure proper ventilation around the BMS to prevent overheating.
- If the heating function is used, periodically inspect the heating elements and temperature switch.
- Refer to the APP for parameter settings and adjust as needed based on battery health and environmental conditions.
8. User Tips
- For optimal performance, ensure your battery pack is well-matched to the BMS's string count and current capabilities.
- Utilize the mobile APP for real-time monitoring and fine-tuning of protection parameters to suit your specific battery chemistry and usage patterns.
- When setting up parallel BMS systems, carefully configure the address dial switches to ensure proper communication between units and the host computer.
- In cold climates, enable the heating function to maintain battery efficiency and prevent damage.
9. Packing List
The following items are included in your JIKONG V19 JK-PB2A16S20P Smart BMS package:

Image description: Visual representation of the JIKONG BMS packing list, including the BMS unit, interface board, various adapter cables, network cable, sampling lines, switch, and heating adapter cable.
| No. | Name | Model | Quantity |
|---|---|---|---|
| 1 | Interface board | JK-CN-Link | 1 |
| 2 | M6 screw | M6*10 | 4 |
| 3 | Interface adapter cable | HY2.0-XH2.54-22AWG-30CM | 1 |
| 4 | Interface adapter cable | 2XH2.54-22AWG-30CM | 1 |
| 5 | Interface adapter cable | IDC2.54mm-20P-30CM | 1 |
| 6 | Dry contact terminal | WJ15EDGK-3.81-4P | 1 |
| 7 | RJ45 network cable | CAT5E-8P twisted pair-40CM | 1 |
| 8 | Balance sampling cable | HY2.0-7P-22AWG-90CM-1 | 1 |
| 9 | Balance sampling cable | HY2.0-6P-Blue casing-22AWG-90CM-2 | 1 |
| 10 | Balance sampling cable | HY2.0-7P-Red casing-22AWG-90CM-3 | 1 |
| 11 | Balance sampling cable | HY2.0-6P-Yellow casing-22AWG-90CM-4 | 1 |
| 12 | Device activation switch | GH1.25-6P-50CM terminal wire | 1 |
| 13 | Energy storage board power cable | 18AWG-Red-50CM +M3 copper nose | 1 |
| 14 | Heating wire | OT2.5-3-14AWG-150MM-Double head | 1 |
10. Support and Documentation
For detailed technical support, advanced troubleshooting guides, and the complete product specification, please refer to the official user manual PDF: JIKONG BMS User Manual (PDF).
For further assistance, please contact JIKONG customer service.