PowMr 3.2V LiFePO4 Battery Cells (50Ah, 100Ah, 280Ah variants)

Contents

PowMr LiFePO4 Battery Cell Instruction Manual

For 3.2V Lithium Iron Phosphate Deep Cycle Battery Cells (50Ah, 100Ah, 280Ah)

1. Introduction

This manual provides essential information for the safe and efficient use of your PowMr 3.2V LiFePO4 (Lithium Iron Phosphate) battery cells. These high-quality, Grade A cells are designed for various deep cycle applications, including DIY 12V, 24V, 36V, and 48V solar energy storage systems. Each cell is brand new with 0 cycles and offers a long cycle life of over 4000 times (at 80% DOD). Please read this manual thoroughly before installation and operation.

Four PowMr 3.2V LiFePO4 battery cells with connectors, highlighting 50Ah, 100Ah, 280Ah options and 4000+ cycle life.
Figure 1: PowMr 3.2V LiFePO4 Battery Cells (various capacities)

2. Safety Information

Lithium Iron Phosphate batteries are generally safe, but improper handling can lead to hazards. Always follow these safety guidelines:

  • Do not short-circuit the battery terminals.
  • Do not expose batteries to fire or extreme heat.
  • Do not immerse batteries in water or other liquids.
  • Do not puncture, damage, or disassemble the battery cells.
  • Use appropriate personal protective equipment (PPE) such as gloves and eye protection during handling and installation.
  • Ensure proper ventilation when charging or discharging batteries.
  • Keep batteries out of reach of children and pets.
  • Only use chargers specifically designed for LiFePO4 batteries with the correct voltage and current settings.
  • In case of leakage, contact with skin or eyes, rinse immediately with plenty of water and seek medical attention.

3. Specifications

The following table details the general specifications for the PowMr 3.2V LiFePO4 battery cells. Note that weight and size may vary slightly depending on the specific capacity (50Ah, 100Ah, or 280Ah).

Feature Specification
Product Name Lithium Iron Phosphate Battery Cell
Grade Grade A
Material Aluminum Housing
Nominal Voltage 3.2V
Rated Capacity Options 50Ah, 100Ah, 280Ah
Minimum Capacity 50Ah/100Ah/280Ah (corresponding to rated)
Internal Resistance < 1.5mΩ
Suggested Constant Charging Current 15A (0.5C)
Recommended Constant Discharging Current 30A (1C)
Maximum Continuous Discharge Current 30A (1C)
Maximum Charging Voltage 3.65V
Discharge Cut-off Voltage 2.5V
Charging Method CC / CV (Constant Current / Constant Voltage)
Cycle Life ≥4000 times (80% DOD)
Charging Temperature -10°C to 45°C
Discharge Temperature -35°C to 65°C
Battery Included Yes
High-concerned chemical None
Certification CE

Dimensions and Weight (Approximate for 50Ah cell)

  • Weight: 0.6kg ± 0.1kg
  • Size: 20mm (Thickness) x 110mm (Width) x 140mm (Height)
Side profile of a single LiFePO4 battery cell. Side profile of a single LiFePO4 battery cell showing terminals.
Figure 2: Side views of a single LiFePO4 battery cell.

4. Setup and Installation

These battery cells are designed for DIY assembly into larger battery banks (e.g., 12V, 24V, 36V, 48V). Proper connection is crucial for safety and performance. Always use a Battery Management System (BMS) for safety and balancing when assembling a multi-cell battery pack.

4.1 Unpacking and Inspection

  • Carefully unpack the battery cells and included accessories (metal connectors, nuts, flat washers).
  • Inspect each cell for any visible damage (e.g., dents, leaks, swollen casing). Do not use damaged cells.
  • Verify that the nominal voltage of each cell is approximately 3.2V.

4.2 Connecting Cells in Series/Parallel

To build a battery bank with higher voltage or capacity, you will connect multiple 3.2V cells in series or parallel:

  1. **Series Connection (for higher voltage):** Connect the positive terminal of one cell to the negative terminal of the next cell. For example, four 3.2V cells in series will create a 12.8V battery bank.
  2. **Parallel Connection (for higher capacity):** Connect positive terminals together and negative terminals together. This increases the overall capacity while maintaining the 3.2V nominal voltage.
  3. **Series-Parallel Combination:** For higher voltage and capacity (e.g., 48V 280Ah), you will combine series and parallel connections.
Close-up view of a single LiFePO4 battery cell's terminals, showing the positive and negative posts with screws.
Figure 3: Battery cell terminals for connection. Each cell includes 1 metal connector, 2 metal nuts, and 2 flat washers.

4.3 Terminal Connection Procedure

  1. Identify the positive (+) and negative (-) terminals on each cell.
  2. Place a flat washer onto the terminal post.
  3. Position the metal connector (bus bar) over the terminal post.
  4. Place another flat washer on top of the connector.
  5. Secure the connection with a metal nut.
  6. Tighten the nut firmly but do not overtighten to avoid damaging the terminal.
  7. Ensure all connections are clean and secure to minimize resistance and prevent overheating.
Four 3.2V 50Ah LiFePO4 battery cells with included metal connectors and nuts, ready for assembly.
Figure 4: Example of 50Ah cells with connectors for assembly.

5. Operating Instructions

Once your battery bank is assembled and connected to a suitable BMS and charging/discharging system, follow these guidelines for operation.

5.1 Charging

  • Always use a dedicated LiFePO4 charger or charge controller that supports CC/CV (Constant Current/Constant Voltage) charging.
  • Ensure the charger's voltage matches your battery bank's nominal voltage (e.g., 12.8V for a 4-cell series bank).
  • The maximum charging voltage for a single cell is 3.65V. For a 12.8V bank, this means a maximum of 14.6V (3.65V x 4 cells).
  • The suggested constant charging current is 15A (0.5C). Avoid charging at currents higher than 1C (e.g., 50A for a 50Ah cell) unless specified by your BMS.
  • Charge within the recommended temperature range of -10°C to 45°C.

5.2 Discharging

  • The discharge cut-off voltage for a single cell is 2.5V. Your BMS should prevent discharge below this level to protect the cells.
  • The recommended constant discharging current is 30A (1C).
  • The maximum continuous discharge current is 30A (1C). Exceeding this can lead to overheating and damage.
  • Discharge within the recommended temperature range of -35°C to 65°C.

6. Maintenance

Proper maintenance will extend the lifespan and ensure the optimal performance of your LiFePO4 battery cells.

  • **Regular Inspection:** Periodically check the battery cells and connections for any signs of damage, corrosion, or loose terminals.
  • **Cleanliness:** Keep the battery terminals and surfaces clean and free from dust and debris. Use a dry cloth for cleaning.
  • **Temperature Control:** Operate and store batteries within the specified temperature ranges. Extreme temperatures can degrade performance and lifespan.
  • **BMS Monitoring:** If using a BMS, regularly monitor cell voltages and temperatures to ensure proper balancing and operation.
  • **Storage:** For long-term storage, charge the cells to approximately 50% of their capacity (around 3.3V-3.4V per cell) and store them in a cool, dry place. Avoid storing fully charged or fully discharged.

7. Troubleshooting

This section addresses common issues you might encounter with your LiFePO4 battery cells.

Problem Possible Cause Solution
Battery not charging
  • Charger not connected or faulty.
  • BMS in protection mode (over-discharge, over-voltage, temperature).
  • Incorrect charger settings.
  • Loose connections.
  • Check charger connection and functionality.
  • Inspect BMS status; address the protection trigger (e.g., warm up cold cells, reduce load).
  • Verify charger voltage and current settings are correct for LiFePO4.
  • Tighten all terminal connections.
Battery not discharging/low power output
  • BMS in protection mode (over-discharge, over-current, temperature).
  • Battery is fully discharged.
  • Loose or corroded connections.
  • Load exceeds battery's continuous discharge current.
  • Inspect BMS status; address the protection trigger.
  • Charge the battery.
  • Clean and tighten all terminal connections.
  • Reduce the load or ensure it's within the battery's specifications.
Battery overheating
  • Overcharging or over-discharging.
  • High ambient temperature.
  • Internal short circuit (rare for new cells).
  • Poor ventilation.
  • Stop charging/discharging immediately. Allow to cool. Review charging/discharging parameters.
  • Move battery to a cooler environment or improve ventilation.
  • If overheating persists, discontinue use and contact support.

8. Warranty and Support

Your PowMr LiFePO4 battery cells come with a warranty to ensure your satisfaction and product reliability.

  • **Warranty Period:** 60 months (5 years) from the date of purchase.
  • This warranty covers defects in materials and workmanship under normal use.
  • It does not cover damage caused by misuse, abuse, improper installation, unauthorized modifications, or natural disasters.
  • For warranty claims or technical support, please contact PowMr customer service through your purchase platform or the official PowMr website.
Warranty and service information graphic, indicating 1-year warranty and customer support.
Figure 5: General Warranty and Service Information.

Ask a question about this manual