The SUMRY EP-4200H is a pure sine wave solar inverter designed for off-grid applications, offering flexible power solutions with dual voltage compatibility. It can operate at either 12VDC or 24VDC, providing rated output power of 2300W at 12VDC and 4200W at 24VDC. This inverter features a 100A MPPT solar charger, ensuring efficient power conversion from solar panels. It is suitable for a wide range of household appliances and can integrate with solar energy, utility grids, and generators simultaneously.

SUMRY EP-4200H Solar Inverter with key specifications
Figure 1: SUMRY EP-4200H Solar Inverter highlighting 230VAC output, 100A Max PV Charge Current, 55-500VDC MPPT range, and 50/60Hz frequency.

2. Safety Information

CAUTION: Before connecting the PV module, always install a separate DC circuit breaker between the inverter and the PV module.

WARNING: All wiring must be performed by qualified personnel to ensure system safety and efficient operation. Using appropriate cable sizes for PV module connections is crucial to reduce the risk of injury. Refer to the recommended cable size table in the setup section.

This device handles high voltages and currents. Improper installation or operation can lead to serious injury or damage to equipment. Always follow local electrical codes and safety standards.

3. Product Features

  • Dual Voltage Operation: Works at 12VDC (2300W rated power) or 24VDC (4200W rated power) to meet diverse load requirements.
  • Pure Sine Wave Output: Provides clean and stable power suitable for sensitive electronics.
  • Integrated MPPT Solar Charger: Built-in 100A MPPT controller with an operating voltage range of 55V-500VDC and open circuit voltage up to 500VDC for maximum solar energy harvesting.
  • Flexible Power Source: Can power loads using solar energy and the utility grid simultaneously.
  • Battery Compatibility: Compatible with various battery types including GEL, LI (Lithium-ion), AGM, and FLD (Flooded), with user-configurable settings.
  • Smart Device Integration: Features an RS485 port for communication with Battery Management Systems (BMS) and optional Wi-Fi/GPRS for remote monitoring via the Sun House App.
  • Protection Features: Includes overload, over-temperature, and short-circuit protection.
  • Automatic Restart: Automatic restart function when mains power is restored.
  • Intelligent Charging: Designed for optimized battery utilization.
  • Durable Design: Built-in anti-dust kit and dustproof construction.
  • User Interface: LCD display and RGB lights for status indication.
List of features for the SUMRY solar inverter
Figure 2: Key features of the SUMRY EP-4200H inverter.

4. Product Appearance and Components

The SUMRY EP-4200H inverter features a sleek, wall-mountable design. Below are diagrams illustrating the product's dimensions and key components.

Dimensions of the SUMRY EP-4200H inverter
Figure 3: Inverter dimensions (Height: 405mm, Width: 305mm, Depth: 108mm).
System diagram and component overview of the SUMRY EP-4200H inverter
Figure 4: System Diagram and Product Overview with labeled components.

Component Identification:

  1. LCD screen
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function keys (ESC, UP, DOWN, ENTER)
  6. Power on/off switch
  7. AC input terminal
  8. AC output terminal
  9. PV input terminal
  10. Battery input terminal
  11. Circuit breaker
  12. Ground wire terminal
  13. BMS communication port
  14. RS232 communication port

5. Specifications

General Specifications:

AttributeSpecification
Model NumberEP-4200H
Output TypeSINGLE (Pure Sine Wave)
Output Voltage230VAC ±5%
Output Frequency50/60Hz auto sensing
Output Current20A
Max. PV Array Power4000W
MPPT Voltage Range55-500VDC
Max. PV Open Circuit Voltage500VDC
Max. Charge Current100A
Weight8kg
Dimensions (H x W x D)405mm x 305mm x 108mm
Is Smart DeviceYes
CertificationCE

Performance by Battery Voltage:

Battery VoltageRated Output PowerSurge Power
12VDC2300W4600W
24VDC4200W8400W
Detailed specifications table for 2.3KW and 4.2KW models
Figure 5: Detailed specifications for 12VDC (2.3KW) and 24VDC (4.2KW) operation.

6. Setup and Installation

Proper installation is critical for the safe and efficient operation of your SUMRY EP-4200H inverter. Ensure all wiring is done by qualified personnel.

6.1 PV Connection

Before connecting the PV module, install a DC circuit breaker between the inverter and the PV module. Use appropriate cable sizes as recommended below:

ModelWire GaugeTorque Value
12V/24V1 * 16 AWG1.2-1.6 Nm

PV Module Selection:

When selecting proper PV modules, consider the following parameters:

  • Open circuit Voltage (Voc) of PV modules should not exceed the max. PV array open circuit voltage of the inverter (500VDC).
  • Open circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
ParameterValue
Max. PV Array Power4000W
I Max. PV18A
Nominal PV Voltage240V
PV Array MPPT Voltage Range55V-500V
Max. PV Open Circuit Voltage500V

Example PV Module Configuration (250Wp module):

Solar Panel Parameters - 250WpRange (Min in serial: 6 pcs, Max in serial: 11 pcs)Q'ty of PanelsTotal Input
-Vmp: 30.1Vdc3 pcs in serial3750W
-Imp: 8.3A6 pcs in serial61500W
-Voc: 37.7Vdc8 pcs in serial82000W
-Isc: 8.4A12 pcs in serial123000W
-Cells: 6013 pcs in serial133250W
8 pcs in serial and 2 sets in paralleled164000W

6.2 Battery Connection

The inverter supports both 12VDC and 24VDC battery configurations. Ensure correct polarity and secure connections.

  • For 12V/2300W operation: Connect 12V batteries in parallel.
  • For 24V/4200W operation: Connect two 12V batteries in series to achieve 24V.
Diagram showing parallel and series battery connections for 12V and 24V operation
Figure 6: Battery connection diagrams for 12V (parallel) and 24V (series) configurations.

6.3 BMS Communication (for Lithium Batteries)

Connect the RJ45 communication cable between the inverter and the battery's BMS port. Confirm that the lithium battery BMS port's PIN definition corresponds with the inverter BMS communication port. The inverter BMS port's PIN definition is as follows:

Pin NumberPort Definitions
1RS485B
2RS485A
3NG
4NG
5NG
6NG
7RS485A
8RS485B

6.4 System Connection Diagram

The inverter can be integrated into a comprehensive power system including solar panels, batteries, a generator, and the utility grid, supplying power to various household appliances.

Diagram showing how the inverter connects to solar panels, battery, generator, utility grid, and household appliances
Figure 7: Link instructions showing the inverter's role in a complete power system.

7. Operating Instructions

7.1 LCD Display and Function Keys

The front panel of the inverter features an LCD screen (1) for displaying operational status and settings, along with status (2), charging (3), and fault (4) indicators. Navigation and configuration are performed using the function keys (5): ESC, UP, DOWN, and ENTER.

7.2 Monitoring and Control

The inverter can be monitored and controlled remotely via the 'Sun House App'. This requires an optional Wi-Fi distribution network module, which connects to the inverter's communication port.

Image showing remote monitoring via Sun House App with optional Wi-Fi module
Figure 8: Remote monitoring and control via the Sun House App with an optional Wi-Fi module.

8. Maintenance

To ensure the longevity and optimal performance of your SUMRY EP-4200H inverter, regular maintenance is recommended:

  • Cleaning: Keep the inverter's exterior clean and free from dust. The built-in anti-dust kit helps, but periodic external cleaning is still beneficial.
  • Ventilation: Ensure that the inverter's ventilation openings are not blocked to prevent overheating.
  • Connections: Periodically check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Environment: Operate the inverter within its specified environmental conditions (temperature, humidity) to prevent damage.

9. Troubleshooting

This section provides guidance on common issues you might encounter with your inverter.

  • Inverter not turning on: Check the power on/off switch (6), battery connections, and the circuit breaker (11). Ensure the battery voltage is within the operational range.
  • No output power: Verify AC input (7) and output (8) connections. Check for fault indicators (4) on the LCD.
  • Fault Indicator lit: Refer to the LCD display for specific error codes or messages. Common faults include overload, over-temperature, or short circuit. Reduce load, ensure proper ventilation, or check for wiring issues.
  • No solar charging: Check PV input (9) connections and ensure solar panels are receiving adequate sunlight. Verify PV module selection parameters are correct.
  • Inverter not working without battery: This inverter requires a battery to function. It does not operate solely on solar panels without a battery connected.

10. User Tips

  • Battery Selection: Ensure your battery system (12V or 24V) matches the inverter's configuration for optimal performance.
  • Cable Sizing: Always use appropriately sized cables for all connections (PV, battery, AC) to prevent power loss and ensure safety.
  • Monitoring App: Utilize the 'Sun House App' with the optional Wi-Fi module for convenient remote monitoring of your system's performance and status.
  • Noise during Charging: Some users have reported operational sounds during battery charging. Ensure the inverter is installed in a well-ventilated area and consider its placement to minimize any potential noise impact.

11. Warranty and Support

For warranty information, technical support, or service inquiries, please contact your original seller or the manufacturer directly. Keep your purchase receipt and product serial number handy for faster service.

© 2025 SUMRY. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.