JIKONG V19 JKBMS

Contents

JIKONG V19 JKBMS Lithium Battery Active Balance Protection Board User Manual

Model: V19 JKBMS

1. Product Overview

The JIKONG V19 JKBMS is an intelligent protection board designed for large-capacity series lithium battery packs. It integrates essential functions such as voltage acquisition, high-current active balancing, overcharge, over-discharge, overcurrent, over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. This system is suitable for various battery types, including lithium iron phosphate, ternary lithium, and lithium titanate batteries.

The protection board utilizes energy transfer active balancing technology to achieve a maximum continuous 1A or 2A balance current, depending on the model. This high-current active equalization technology ensures battery consistency, extends battery range, and delays battery aging. It features a mobile APP compatible with Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. Its compact size, simple operation, and comprehensive functions make it ideal for high-power energy storage, base station backup power, and solar power station battery packs.

2. Specifications

2.1. General Parameters

ParameterValueUnit
Supply Voltage20-70V
Standby Power Consumption12mW
Operating Power Consumption1100mW
Operating Temperature-30 to 70°C
Max. Number of Collection Strings16S
Max. Balancing Current1 or 2A
Max. Internal Loop Resistance0.25 - 1mΩ
Protective Plate Size300 x 100 x 24mm
Finished Weight1000g

2.2. Model-Specific Current Ratings

ModelBalance CurrentContinuous Discharge CurrentMax. Charging Current (ADJ)
JK-PB1A16S10P1A100A200A
JK-PB1A16S15P1A150A300A
JK-PB2A16S15P2A150A300A
JK-PB2A16S20P2A200A350A
JK-PB2A16S30P2A300A600A

2.3. Supported Battery Types and String Counts

Battery TypeAdaptive Battery Strings
Ternary Lithium Battery8-16S
Lithium Iron Battery (LiFePO4)7-16S
Lithium Titanate Battery (LTO)14-16S

2.4. Default Protection Parameters (Example for LiFePO4)

ParameterValueUnit
Balancing Initial Voltage3V
Unit Overcharge Voltage3.6V
Single Overcharge Protection Recovery3.54V
Monomer Undervoltage Protection2.6V
Single Undervoltage Protection Recovery2.65V
Automatic Shutdown Voltage2.5V
SOC-0% Voltage2.6V
SOC-100% Voltage3.5V
Trigger Balancing Differential Pressure0.01V
Charging Overcurrent Protection Delay3S
Charging Overcurrent Protection Release Time60S
Discharge Overcurrent Protection Delay300S
Discharge Overcurrent Protection Release Time60S
Short-circuit Protection Delay5µS
Short-circuit Protection Release Time30S
Charging Overtemperature Protection70°C
Charging Overtemperature Recovery60°C
Discharge Overtemperature Protection70°C
Discharge Overtemperature Recovery60°C
Charging Low Temperature Protection-20°C
Charging Low Temperature Recovery-10°C
MOS Overtemperature Protection100°C
MOS Overtemperature Recovery80°C

3. Setup

3.1. Packing List

Ensure all components are present before proceeding with installation.

Packing list for JIKONG V19 JKBMS showing BMS, interface board, adapter cables, network cable, sampling lines, switch, and heating adapter cable.

Packing List includes:

  1. BMS x 1
  2. Interface board x 1
  3. Adapter cable B x 1 (long 30cm)
  4. Adapter cable A x 1 (long 30cm)
  5. RS485 Network cable x 1 (long 40cm)
  6. Cells total B+ Cable x 1 (long 50cm)
  7. Sampling line A x 2 (long 90cm)
  8. Sampling line B x 1 (long 90cm)
  9. Sampling line C x 1 (long 90cm)
  10. Switch x 1 (long 50cm)
  11. Adapter cable C x 1 (long 30cm)
  12. Heating Adapter cable x 1 (long 17cm)
  13. Adapter x 1

3.2. Wiring and Installation

The JIKONG V19 JKBMS is suitable for 7-16 series lithium battery packs. The specific wiring method depends on the number of cells in your battery pack. Always ensure correct connections to prevent damage.

Wiring diagram for 16-string and 8-string cells for JIKONG V19 JKBMS.

Wiring Steps:

  1. Connect all the cables to their respective ports on the BMS.
  2. Insert the balance cable into the BMS.
  3. Connect the B- line and the P- line to the battery.
  4. If there are two B8 cables, only the first B8 line needs to be connected. The second B8 cable is not required.

Refer to the detailed connector definitions and interface board diagrams for precise connections.

Diagram showing the internal components and flexible wiring terminals of the JIKONG V19 JKBMS.

Image: Internal components and flexible wiring terminals.

Diagram illustrating the four communication modes and mainstream interfaces of the JIKONG V19 JKBMS, including CAN, RS485, UART, RS232, Parallel Module, Interface Board, Active Equalizer, and NTC.

Image: Four communication modes and mainstream interfaces.

3.3. Device Activation

Before powering on the protection board, double-check that the balance cables are correctly connected and that the P- and B- terminals are properly wired. Ensure the protection board is securely fixed to the battery cells. Incorrect connections can lead to abnormal operation or damage.

The protection board does not have a power-on control switch. It is designed for charging activation mode, meaning the charger voltage must be 2V higher than the battery voltage. After assembling the battery, connect the charger to activate the protection board.

Alternatively, the protection board supports key activation and display activation. If you have an optional display screen and button, simply insert the cable into the display interface and press the button to activate.

3.4. Mobile APP Installation

The mobile APP for the JIKONG V19 JKBMS allows for convenient monitoring and parameter adjustments. An Android device with version 7 or higher is required.

QR code for JIKONG mobile APP download.

Scan the QR code above to download the JIKONG mobile APP.

4. Operating Instructions

4.1. Active Equalization

The BMS uses active equalization to transfer energy from high-voltage cells to low-voltage cells, maintaining battery consistency. Before using this function, set basic battery parameters in the APP, including cell count, battery capacity, trigger equalization differential pressure (default can be retained), voltage calibration, and current calibration.

You can set the balance trigger pressure difference (mV) in the APP. When balancing is enabled, it automatically activates if the voltage difference between any two battery strings exceeds the set value, and deactivates when the difference falls below the set value. The default balance current is 1A/2A. Adjust this current based on your battery capacity, ensuring it does not exceed 0.2C of the battery capacity. If not needed, disable balancing in the APP's BMS control page.

4.2. Display Interface

The protection board includes a reserved display interface. You can connect an optional JIKONG display to conveniently view battery information such as voltage, current, temperature, and state of charge.

JIKONG V19 4.3 inch display showing battery voltage, current, temperature, and state of charge.

Image: JIKONG V19 4.3 inch display.

Video: V19 BMS + V19 4.3 inch Touch screen PB series user show.

4.3. Heating Function

The BMS comes standard with a heating function. In low-temperature conditions, a resistance heater or heating film can be used to warm the battery, preventing reduced activity and charging/discharging issues. The designed heating current is 10A. Control this function via the APP's BMS control page. It is recommended to install a normally closed temperature switch (45-65°C) in series with the heating circuit as a secondary safety measure.4.4. Dry Contact Function

Two dry contacts are provided to control external devices like alarms and fans. When the BMS detects conditions such as over-temperature, overcharge, or over-discharge, the alarm interface can switch the dry contact status to trigger a buzzer or activate a fan for cooling. You can select two trigger conditions in the APP based on your needs.

4.5. Intelligent Sleep

The intelligent sleep function, enabled or disabled via the APP, conserves battery energy. If the BMS is in standby (charging/discharging current less than 1A for 26 consecutive hours), it will enter sleep mode. To reactivate, press the button or connect a charger.

4.6. Communication Functions (CAN, RS485, UART)

The BMS supports CAN and RS485 communications. CAN communication defaults to 250K. Users can select inverter communication protocols in the APP. Two RS485 interfaces are available: RS485-1 for inverter communication and RS485-2 for parallel battery pack monitoring and communication with a host computer. The default baud rate for RS485-2 is 115200. The BMS address can be set using DIP switches (0-15).

Mobile app interface for JIKONG V19 JKBMS showing basic settings and protocol selection for inverter communication.

Image: Mobile APP interface for protocol selection.

Host computer interface for JIKONG V19 JKBMS showing real-time data, settings, control, logging, and fault information, including supported CAN protocols.

Image: Host computer interface for monitoring and settings.

4.7. Charge Current Limiting

This function limits the charging current to approximately 10A when an overcurrent condition is detected during charging, protecting the battery. Users can set continuous charging current, overcurrent delay, and release time in the APP.4.8. Parallel Function

The parallel function allows simultaneous monitoring of multiple BMS units via an RS485 bus using a host computer. This requires a USB to RS485 serial port cable and the JIKONG host computer software. Up to 16 BMS units can be connected, with addresses 0-15 set via DIP switches (address 0 is the host, 1-15 are slaves).

Diagram showing multiple JIKONG BMS units connected in parallel for monitoring.

Image: JIKONG energy storage series protection board parallel monitoring diagram.

5. Maintenance and Protection Features

The JIKONG V19 JKBMS includes various protection mechanisms to ensure the longevity and safety of your battery system. These features automatically activate and recover under specific conditions.

5.1. Overcharge Protection and Recovery

The BMS protects against overcharging. If any cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the overcharge recovery voltage. Users can set these voltage thresholds in the APP.

5.2. Undervoltage Protection and Recovery

To prevent over-discharge, the BMS monitors cell voltages. If any cell's voltage falls below the undervoltage protection voltage during discharge, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the undervoltage recovery voltage. An automatic shutdown voltage is also set, below which the BMS will shut down to protect the battery. These parameters are configurable via the APP.

5.3. Overcurrent Protection and Recovery (Charge & Discharge)

The BMS features overcurrent protection for both charging and discharging. If the current exceeds the set continuous current for a specified delay, the BMS will trigger protection and stop the respective operation. It will resume after the overcurrent release time has passed. Continuous current, delay, and release times are adjustable in the APP.

5.4. Over/Low Temperature Protection and Recovery

The BMS monitors battery temperature. If the temperature exceeds the over-temperature protection value during charging or discharging, the BMS will stop the operation. It will resume when the temperature falls below the recovery value. Similarly, if the temperature drops below the low-temperature protection value during charging, the BMS will stop charging and resume when the temperature rises above the recovery value. All temperature thresholds are configurable in the APP.

5.5. Short Circuit Protection and Recovery

The BMS includes short-circuit protection. While the trigger current is not user-settable, the short-circuit protection delay and recovery time can be adjusted in the APP. This helps prevent damage from sudden current spikes, especially during initial connection of chargers or loads. If a short circuit occurs, the BMS will stop operation and resume after the recovery time.5.6. Emergency Switch

In case of issues like over-temperature, over-discharge, overcharge, or cell string drops, activating the emergency switch in the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides a temporary operational window, even if cell voltages have reached the automatic shutdown threshold, to prevent critical situations.

6. Troubleshooting

Many issues can be resolved by checking connections, APP settings, and observing LED indicators.

6.1. LED Indicators

The interface board features LED indicators to help diagnose the BMS status:

  • Bluetooth Status: Steady ON when connected, blinking when disconnected.
  • Power LED (L1-L5): Indicates battery capacity (0-100%) and charging/discharging status.
  • L6 LED: Blinks if device address is set to 0 (host), OFF if set to other values (slave). Blinks after successful communication between slave and host.
  • RUN LED: Indicates normal operation.
  • ALM LED: Indicates an alarm or protection event.

6.2. Common Issues and Solutions

  • BMS not activating: Ensure all balance cables and P-/B- connections are correct. Verify the charger voltage is at least 2V higher than the battery voltage for charging activation. If using a display, ensure it's connected and the activation button is pressed.
  • Balancing not occurring: Check APP settings for active equalization. Ensure the trigger differential pressure is met. Verify battery parameters (cell count, capacity) are correctly set.
  • Overcurrent/Overvoltage/Overtemperature protection triggering frequently: Review and adjust the protection parameters (current limits, voltage thresholds, temperature limits, delays, and recovery times) in the APP to match your battery and load characteristics.
  • Communication issues (CAN/RS485): Verify cable connections. Check DIP switch settings for correct addresses in parallel configurations. Ensure the correct inverter protocol is selected in the APP.
  • Display not showing data: Ensure the display is properly connected to the interface board. Check for power to the display.

7. User Tips

  • Optional Display: The 4.3-inch display is an optional accessory. If you wish to have a physical screen for monitoring, it needs to be acquired separately. The BMS can still be fully managed via the mobile APP without the physical display.
  • Parallel System Setup: When connecting multiple 48V battery packs with individual BMS units to a hybrid inverter, utilize the RS485 parallel function. Each BMS needs a unique address set via its DIP switches (0 for host, 1-15 for slaves). Connect them in sequence using RJ45 Ethernet cables to the host computer for monitoring.
  • Parameter Adjustment: Always refer to the detailed parameter setting instructions in the full user manual (PDF) before making changes in the APP. Incorrect settings can affect performance and safety.
  • Low Temperature Operation: For extremely cold environments, consider utilizing the heating function to maintain optimal battery performance and prevent low-temperature protection from triggering.

8. Warranty and Support

This product is manufactured by Chengdu Jikong Technology Co. LTD. For detailed warranty information, technical support, or service inquiries, please refer to the official documentation or contact JIKONG customer service.

A comprehensive user manual in PDF format is available for download, providing in-depth information on all aspects of the JIKONG V19 JKBMS. You can find the PDF at: JIKONG V19 JKBMS User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.