SUMRY EP4200-H

Contents

SUMRY EP4200-H Dual Voltage Solar Inverter User Manual

Model: EP4200-H | Brand: SUMRY

1. Introduction

This manual provides detailed instructions for the assembly, installation, operation, and troubleshooting of the SUMRY EP4200-H Solar Inverter. Please read this manual carefully before proceeding with installation and operation to ensure safe and efficient use.

The EP4200-H is a multifunctional off-grid solar inverter, integrating an MPPT solar charging controller, a high-frequency pure sine wave inverter, and a UPS function module. It is designed for off-grid backup power supply and self-consumption systems. Its high-frequency transformer design ensures reliable power conversion in a compact size. This inverter can also operate in battery-free mode.

A complete system typically requires additional equipment such as photovoltaic modules, a generator, or a utility grid. A Wi-Fi module is available as a plug-and-play monitoring device, allowing users to monitor the solar system's status via mobile phones or websites.

Key Features:

  • Pure sine wave output inverter.
  • Selectable utility grid input voltage range (for household appliances/personal computers).
  • Adjustable charging current via LCD based on battery requirements.
  • Simultaneous power supply to loads from solar energy and utility grid.
  • AC input compatible with both mains and generators.
  • Automatic restart function upon mains power restoration.
  • Overload, over-temperature, and short-circuit protection.
  • Intelligent charging design for optimal battery utilization.
  • RS485 port for communication with BMS.
  • Cold start function.
  • Built-in MPPT with an operating voltage range of 55-500VDC and an open circuit voltage of 500VDC.
  • WIFI remote monitoring and Bluetooth near-end sampling.
  • Leakage current protection function.
  • 12V/24V battery adaptive: 12V rated voltage supports 2300W, 24V rated voltage supports 4200W.
  • Dual-use functionality.
SUMRY EP4200-H Inverter Features

Figure 1: Key Features of the SUMRY EP4200-H Inverter

Basic System Architecture:

The inverter/charger can be integrated into a system that includes a generator or mains electricity and optional solar modules. It is capable of powering various home and office appliances, including motor-type appliances like tube lights, fans, refrigerators, and air conditioners.

SUMRY EP4200-H System Link Instructions

Figure 2: Basic System Architecture and Link Instructions

2. Safety Regulations

Warning: This article contains important safety and operation instructions. Please read and save this manual for future reference.

  • Always choose the corresponding battery settings (lead-acid or lithium) to ensure normal system operation.
  • Before use, read all instructions and cautions on the unit and understand all battery models and relevant chapters in this manual.
  • Never short-circuit AC output and DC input. Do not connect to mains when DC input is short-circuited.
  • Never attempt to charge non-rechargeable batteries.
  • Do not disassemble the unit. For maintenance or repair, send it to a professional technical service center. Incorrect reassembly can lead to electric shock or fire.
  • To reduce electric shock risk, disconnect all wiring before maintenance or cleaning. Turning off the device alone does not eliminate this risk.
  • Exercise extreme caution when using metal tools near batteries to prevent short circuits or explosions.
  • Use appropriate cable sizes for battery connections as recommended in this manual for system safety and efficient operation.
  • When disconnecting AC or DC terminals, strictly follow the installation procedure.
  • Ensure the off-grid solar inverter is connected to a permanent grounding wiring system, complying with local requirements.
  • Provide a fuse with specified ratings for battery power supply overcurrent protection.
  • Warning: Only professional service personnel can repair this equipment. If errors persist after troubleshooting, return the inverter to a local dealer or service center.

3. Setup

3.1 Unpacking and Inspection

Upon receiving the inverter, carefully unpack it and inspect for any damage. Ensure all items are present:

  • Inverter unit x 1
  • User manual x 1

3.2 Preparation Before Installation

Before connecting any wiring, remove the bottom cover by unscrewing the two screws as shown in the diagram below.

SUMRY EP4200-H Inverter Preparation Before Installation

Figure 3: Removing the Bottom Cover for Wiring Access

3.3 Installation Location

Consider the following points for installation:

  • Do not install the inverter on flammable building materials.
  • Install on a solid, non-combustible surface (e.g., concrete).
  • Position the inverter at eye level for easy readability of the LCD display.
  • Maintain a gap of 20-50 cm around the unit for proper ventilation and heat dissipation.
  • Ensure the operating environment temperature is between 0-55°C.
  • It is best to install the unit vertically against a wall, leaving adequate space from the ground.
SUMRY EP4200-H Inverter Installation Guidelines

Figure 4: Recommended Installation Location and Clearance

Tighten the screws to fix the installation. M4 or M5 screws are recommended.

3.4 Battery Connection

WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.

An independent DC overcurrent protector or disconnect device must be installed between the battery and the inverter. All wiring must be performed by qualified personnel. Use appropriate cable sizes for safety and efficient operation.

ModelWire SpecificationTorque Value
2KVA-12V1 * 4 AWG (22mm²)2-3 Nm
3.5KVA-24V1 * 6 AWG (13mm²)2-3 Nm

Lead-Acid Battery Connection:

The recommended charging current for lead-acid batteries is 0.2C (where C is battery capacity).

  1. Connect the battery using the recommended cable specifications.
  2. Connect all battery packs as required.
  3. Insert the ring terminal of the battery cable flatly into the inverter's battery connector. Tighten bolts to 2-3 Nm. Ensure correct polarity (+ to + and - to -).
  4. Connect all battery packs as shown in the diagram for 2KVA/12V (parallel) or 3.5KVA/24V (series).
SUMRY EP4200-H Inverter Battery Connection Diagram

Figure 5: Battery Connection for 12V (Parallel) and 24V (Series) Configurations

Lithium Battery Connection:

Only lithium batteries with matched BMS communication protocol are allowed.

  1. Connect the battery according to recommended cable specifications.
  2. Insert the ring terminal of the battery cable into the inverter's battery connector and tighten bolts to 2-3 Nm. Ensure correct polarity.
  3. Connect one side of an RJ45 cable to the inverter's BMS communication port.
  4. Insert the other side of the RJ45 cable into the lithium battery's RS485 communication port.

Note:

  • Do not place anything between the inverter terminal and the ring terminal to avoid short circuits or overheating.
  • Do not apply antioxidant to the terminal before connection.
  • Before final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
  • If using a lithium battery, ensure BMS communication cable is connected and select "LIB" mode in the inverter settings.

Communication and Setting of Lithium Battery:

Connect the RJ45 communication cable between the inverter and battery. Confirm the lithium battery BMS port's PIN corresponds with the inverter BMS communication port. The inverter BMS port's PIN definition is as follows:

Pin NumberPort Definitions
1TX
2RX
3VCC
4VCC
5RS485A
6RS485B
7GND
8GND
SUMRY EP4200-H Inverter RJ45 Pin Definitions

Figure 6: RJ45 Communication Port Pin Definition

To enable lithium battery BMS communication, press the "ENTER" button for a long time, set the battery type to "LIB" in program 05, and then select the matching battery protocol in Program 10.

3.5 AC Input/Output Connection

CAUTION: Before connecting to the AC input power source, install a separate AC breaker between the inverter and the AC input power source. This ensures the inverter can be securely disconnected during maintenance and is protected from overcurrent.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes for AC input connection for safety and efficient operation.

Suitable Cable Specifications for AC Wires:

ModelWire GaugeTorque Value
2KVA-12V1 * 12 AWG1.2-1.6 Nm
3.5KVA-24V1 * 10 AWG1.2-1.6 Nm

CAUTION: There are two terminal blocks labeled "IN" and "OUT". Do NOT misconnect input and output connectors.

  1. Before making AC input/output connections, open the DC protector or disconnector first.
  2. Remove 10mm of insulation from the six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to the polarities indicated on the terminal block and tighten the terminal screws. Connect the PE protective conductor (yellow-green) first, then LINE (brown or black), and Neutral (blue).
  4. Insert the AC output conductor according to the polarity identification at the terminal and tighten the screw.
  5. Ensure all wires are firmly connected.

WARNING: Ensure the AC power source is disconnected before attempting to hardwire it to the unit.

CAUTION: Ensure all AC cables are connected correctly according to the corresponding polarity.

CAUTION: Appliances like air conditioners require 2-3 minutes to restart to balance refrigerant gas. A brief power shortage and recovery can damage connected appliances. Check if your air conditioner has a time-delay function. Otherwise, the inverter may trigger an overload fault to protect the appliance, but internal damage can still occur.

3.6 PV Connection

CAUTION: Before connecting the PV module, install a separate DC circuit breaker between the inverter and the PV module.

WARNING: All wiring must be performed by qualified personnel. Use appropriate cable sizes for PV module connection to reduce injury risk.

ModelWire GaugeTorque Value
2KVA-12V1 * 10 AWG1.2-1.6 Nm
3.5KVA-24V1 * 10 AWG1.2-1.6 Nm

PV Module Selection:

When selecting PV modules, consider the following:

  1. The open circuit voltage (Voc) of PV modules must not exceed the inverter's maximum PV array open circuit voltage.
  2. The open circuit voltage (Voc) of PV modules should be higher than the minimum battery voltage.
Parameter2KVA-12V3.5KVA-24V
PV open circuit voltage60Vdc60Vdc
MPPT operating voltage range13Vdc~60Vdc13Vdc~60Vdc
Min. battery voltage for PV charge15Vdc15Vdc

PV Module Connection Steps:

  1. Remove 10mm of insulation from positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).
  3. Ensure wires are securely connected.
SUMRY EP4200-H Inverter PV Connection Instructions

Figure 7: PV Connection Guidelines and Solar Input Table

3.7 Final Assembly

After connecting all wires, replace the bottom cover and secure it with screws.

SUMRY EP4200-H Inverter Final Assembly

Figure 8: Final Assembly of the Inverter

4. Operating Instructions

4.1 Power On/Off

After correct installation and battery connection, simply press the On/Off switch to power on the machine.

4.2 Operation and Display

The front panel of the inverter features an LCD screen, four function keys, and LED indicators to show operation status and input/output power information.

SUMRY EP4200-H Inverter System Diagram

Figure 9: System Diagram with LCD, Function Keys, and LED Indicators

Function Keys:

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm selection or enter setting mode

LED Indicators:

LED IndicatorMessages
AC/INV (Green) Solid OnOutput is powered by utility in Line mode.
AC/INV (Green) FlashingOutput is powered by battery or PV in battery mode.
CHG (Green) Solid OnBattery is fully charged.
CHG (Green) FlashingBattery is charging.
FAULT (Red) Solid OnFault occurs in the inverter.
FAULT (Red) FlashingWarning condition occurs in the inverter.

LCD Display Icons:

The LCD displays various information including input source, configuration, fault information, output information, and battery information. Icons indicate AC input, PV input, input/output voltage, frequency, load percentage, and charging status.

4.3 LCD Settings

Press and hold the "ENTER" button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit.

Settings include: Output source priority (Solar first, Utility first, SBU priority), Maximum charging current, AC input voltage range (Appliances/UPS), Power saving mode, Battery type (AGM, Flooded, User Defined, LIB), Auto restart on overload/over temperature, Output voltage, Output frequency, Lithium battery protocol, Bulk charging voltage, Floating charging voltage, Low DC cut-off voltage, Battery equalization settings, Backlight control, Beeps, Overload bypass, Record fault code, and Auto return to default display screen.

4.4 Operating Mode Description

The inverter supports various operating modes:

  • Standby Mode / Power Saving Mode: In standby, the inverter is off but can still charge the battery. In power saving mode (if enabled), the output turns off when the connected load is very low or not detected.
  • Line Mode: The unit provides output power from the mains and charges the battery.
  • Battery Mode: The unit provides output power from the battery and PV power.

4.5 Dry Contact Signal

A dry contact (3A/250VAC) on the rear panel can signal an external device when battery voltage reaches a warning level. The contact status (NC & C, NO & C) changes based on power status and battery voltage thresholds.

5. Maintenance

5.1 Battery Equalization

The inverter includes a battery equalization function to reverse negative chemical effects like stratification and remove sulfate crystals, which can reduce battery capacity. Equalization should be performed periodically.

How to Apply Equalization:

First, enable battery equalization in monitoring LCD setting program 33. Then, you can apply it by:

  1. Setting the equalization interval in program 37.
  2. Activating equalization immediately in program 39.

When to Equalize:

During the float stage, when the set equalization interval is reached or equalization is actively initiated, the controller will enter the Equalize stage. The controller supplies power to charge the battery until it reaches the equalization voltage, then maintains this voltage. The battery remains in the Equalize stage until the set equalized time is reached. If the battery voltage doesn't reach the equalization voltage by the end of the set time, the controller will extend the time until it does. If it still doesn't reach the voltage, the controller will stop equalization and return to the float stage.

5.2 General Maintenance Tips

  • Regularly check all cable connections for tightness and signs of wear or damage.
  • Keep the inverter's ventilation openings clear of dust and debris to ensure proper airflow and prevent overheating.
  • Periodically inspect the battery terminals for corrosion and clean if necessary.
  • Monitor the LCD display for any fault or warning codes and address them promptly.
  • Ensure the ambient temperature around the inverter remains within the specified operating range.

6. Troubleshooting

This section provides guidance on common issues, fault codes, and warning codes. For persistent issues, contact professional service personnel.

6.1 Fault Codes

Fault codes indicate critical errors that require attention. The inverter will display a specific icon for each fault.

Fault CodeFault Event
01Fan is locked when the inverter is turned off.
02Over temperature
03Battery voltage is too high
04Battery voltage is too low
05Output short circuit or over temperature.
06Output voltage is too high
07Exceeding overload time
08BUS voltage is too high
09BUS soft start failed.
13PV voltage is too high
51Over current and surge
52BUS voltage is too low
53Inverter soft start failed.
55Over DC voltage in AC output
56Battery is disconnected
57Current sensor failed.
58Output voltage is too low
59Leakage current protection

6.2 Warning Codes

Warning codes indicate non-critical conditions that may affect performance but do not immediately stop operation. They are often accompanied by beeps.

Warning CodeWarning EventAutomatic Alarm
01Fan is locked when inverter is on.Beep three times every second
03Battery overchargeBeep once every second
04Battery low voltageBeep once every second
07OverloadBeep once every 0.5 second
10Output power is deratingBeep twice every 3 seconds
15PV energy is weakNo Beep
EQBattery equalizationNo Beep

6.3 Troubleshooting Table

ProblemLCD/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD and buzzer active for 3 seconds then off.Battery voltage is too low1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. Battery voltage is far too low.
2. Battery polarity is connected reversed.
1. Check if batteries and wiring are connected well.
2. Re-charge battery.
3. Replace battery.
Input voltage displayed as 0 on LCD.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but unit works in battery mode.Power-on icon of LCD flashes, status indicator flashes.Insufficient quality of AC power (Shore or Generator)1. Check if AC wires are too thin/long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct (UPS → Appliance).
Fault code 07Overload error. Inverter is overload 110% and time is up.Reduce connected load by switching off some equipment.
Fault code 05Output short circuited.Check if wiring is connected well and remove abnormal load.
Buzzer beeps continuously and status indicator icon is always on.Fault code 02Internal temperature of inverter component are overheated.Check whether air flow is blocked or ambient temperature is too high. Return to repair center.
Fault code 03Battery is over-charged. Battery voltage is too high.Check if spec and quantity of batteries meet requirements.
Fault code 01Fan faultReplace the fan
Fault code 06/58Output abnormal1. Reduce connected load.
2. Return to repair center
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart the unit, if error happens again, return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.

7. Specifications

The SUMRY EP4200-H inverter comes in two main configurations: 2KVA-12V and 3.5KVA-24V. Below are detailed specifications for various operating modes.

7.1 General Product Properties

  • Brand Name: SUMRY
  • Model Number: EP4200-H
  • Output Current: 20A
  • Output Power: 2kw (for 12VDC) / 4kw (for 24VDC)
  • Output Type: SINGLE
  • Weight: 8kg
  • Output Frequency: 50/60Hz auto sensing
  • Is Smart Device: Yes
  • Origin: Mainland China
  • Certification: CE

7.2 Specification of LINE Mode (Table 1)

Parameter2KVA-12V3.5KVA-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionBattery mode: Electronic Circuits
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

7.3 Specification of Inverter Mode (Table 2)

Parameter2KVA-12V3.5KVA-24V
Rated Output Power2000VA/2000W3500VA/3500W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency60Hz or 50Hz
Peak Efficiency94%
Overload Protection5s@≥150% load; 10s@110%~150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage12 Vdc24Vdc
Cold Start Voltage11.5 Vdc23.0Vdc
Low DC Warning Voltage
@ Load < 50%11.0Vdc22.0Vdc
@ Load ≥ 50%10.5Vdc21.0Vdc
Low DC Warning Return Voltage
@ Load < 50%11.5Vdc23.0Vdc
@ Load ≥ 50%11.0Vdc22.0Vdc
Low DC Cut-off Voltage
@ Load < 50%10.5Vdc21.0Vdc
@ Load ≥ 50%10Vdc20.0Vdc
High DC Cut-off Voltage16 Vdc31Vdc
No Load Power Consumption<35W
Saving Mode Power Consumption<10W<15W

7.4 Specification of Charging Mode (Table 4)

Parameter2KVA-12V3.5KVA-24V
Charging Current (UPS) @Nominal Input Voltage100A
Bulk Charging Voltage (Flooded Battery)14.629.2
Bulk Charging Voltage (AGM / Gel Battery)14.128.2
Floating Charging Voltage13.5Vdc27Vdc
Charging Algorithm3-Step

7.5 General Specifications (Table 5)

Parameter2KVA-12V3.5KVA-24V
Operating Temperature Range-20°C to 55°C
Storage temperature-25°C~60°C
Dimension (D*W*H), mm390*323*115
Net Weight, kg6.7
SUMRY EP4200-H Inverter Detailed Specifications

Figure 10: Detailed Specifications Table for 2300W and 4200W Models

8. User Tips

  • Battery-Free Operation: The SUMRY EP4200-H inverter can function without a connected battery. However, for optimal performance, backup power, and system stability, connecting a battery is highly recommended.
  • Remote Monitoring: Utilize the optional Wi-Fi module and the "Sun house" App to monitor and control your inverter remotely. This allows you to check system status, adjust settings, and receive alerts from anywhere.
  • Proper Ventilation: Always ensure adequate clearance (20-50 cm) around the inverter for proper heat dissipation. Blocked vents can lead to overheating and reduced performance or damage.
  • Correct Battery Type Selection: When setting up, carefully select the correct battery type (Lead-Acid, Lithium, AGM, GEL, etc.) in the LCD settings. Incorrect selection can lead to improper charging and potential battery damage.
SUMRY EP4200-H Inverter Monitoring via Sun house App

Figure 11: Monitor and Control via Sun house App

9. Warranty and Support

For detailed warranty information and specific terms of service, please refer to the official user manual PDF provided by SUMRY. A comprehensive user manual (PDF) is available for download at this link.

In case of any malfunctions or issues that cannot be resolved using the troubleshooting guide, it is crucial to contact qualified service personnel or the SUMRY Official Store for assistance. Do not attempt unauthorized repairs, as this may void your warranty and pose safety risks.

SUMRY is committed to providing reliable products and support. For further inquiries or technical assistance, please reach out to the official support channels.