1. Introduction
The Smartgen HGM1790N and HGM1780 genset controllers are designed for single unit automation and monitoring control, also suitable for pumping units. These controllers facilitate manual or remote start/stop operations. They monitor and protect genset operation by collecting and analyzing critical data such as generator voltage, current, water temperature, and oil pressure. A graphical LCD monitor on the front panel displays fault conditions and provides effective alarm signals, enabling prompt maintenance. Parameter thresholds and delay values can be adjusted via the front panel or through PC software connected via a USB port.

2. Specifications and Features
2.1 General Specifications
- Power Supply Range: DC (8~35)V, compatible with 12V or 24V starter batteries.
- Display: Graphical LCD display with backlight, LED indicators.
- Operation: Touch-buttons.
- Screen Protection: Hard screen acrylic material.
- Panel Material: Silicone panel and buttons for enhanced temperature adaptation.
- Design: Modular design, self-extinguishing ABS plastic enclosure, embedded installation.
- Dimensions: Refer to Figure 2 for detailed dimensions.

2.2 Measured and Displayed Parameters
| Category | Parameter | Unit |
|---|---|---|
| Generator | Voltage | V |
| Frequency | Hz | |
| Power | kW | |
| Current | A | |
| Load Percentage | % | |
| Engine/Other | Oil Pressure | kPa |
| Temperature | ºC | |
| Fuel Level | % | |
| Total Running Time | H (max. 199999 hours) | |
| Battery Voltage | V | |
| Engine Speed | RPM | |
| Start Times | Accumulated Start Times (max. 199999 times, displayed on PC) | Times |
2.3 Key Features
- Genset fault protection and display functions.
- Three working modes: Manual, Auto, Stop.
- Compatibility with multiple temperature, pressure, and fuel level sensors (user-defined).
- Temperature and pressure sensors can be used in parallel with annunciator for increased protection.
- Multiple crank disconnect conditions selectable (engine speed sensor, oil pressure, generator frequency).
- One configurable input port (digital input or liquid level sensor).
- Four fixed relay outputs: Fuel relay, Start relay, Stop relay, Idle relay.
- One configurable output port (common alarm, fail to stop, preheat, or idle control output).
- Parameters can be set and modified via the front panel or PC software (USB Type-B port).
- Digital regulation of all parameters for higher reliability and stability.
3. Package Contents
The package typically includes:
- 1 x Smartgen HGM1790N or HGM1780 Genset Controller
- Mounting hardware (screws, clips)
- User Manual (this document)
4. Installation
4.1 Mounting
The controller features a modular design for embedded installation. Ensure sufficient space for ventilation and access to wiring terminals. Refer to Figure 2 for precise dimensions to prepare the mounting cutout.
4.2 Wiring
All wiring connections are made to the terminals located on the rear of the controller. Ensure all power is disconnected before attempting any wiring. Use appropriate gauge wires for all connections. Refer to Figure 3 for the detailed wiring diagram and terminal functions.

Terminal Descriptions:
- 1 B-: Battery Negative
- 2 B+: Battery Positive
- 3 Em.Stop Input: Emergency Stop Input
- 4 Fuel Output: Fuel Relay Output
- 5 Crank Output: Crank Relay Output
- 6 Remote Start Input: Remote Start Signal Input
- 7 Aux.Input: Auxiliary Input (configurable)
- 8 Oil Pressure Input: Oil Pressure Sensor Input
- 9 Engine Temp Input: Engine Temperature Sensor Input
- 10 Magnetic Pickup: Magnetic Pickup Sensor Input (for engine speed)
- 11 Gens(L): Generator Line (Phase L)
- 12 Gens(N): Generator Neutral (Phase N)
- 13 Load(L): Load Line (Phase L)
- 14 Aux.Output 1: Auxiliary Output 1 (configurable)
- 15 Aux.Output 2: Auxiliary Output 2 (configurable)
- 16 Aux.Output 3: Auxiliary Output 3 (configurable)
- USB: Type-B USB port for PC software connection.
Ensure correct polarity for battery connections and proper sensor wiring to avoid damage to the controller or genset.
5. Operation
The controller features a user-friendly front panel with an LCD display, LED indicators, and touch-buttons for operation. Refer to Figure 4 for an overview of the front panel.


5.1 Working Modes
The controller supports three primary working modes:
- Manual Mode: Allows the user to manually start and stop the genset using the front panel buttons.
- Auto Mode: The genset will automatically start and stop based on configured remote start/stop signals or other programmed conditions.
- Stop Mode: The genset is stopped and will not start automatically.
5.2 Button Functions
- Stop Button (Red): Used to stop the genset in Manual mode or to exit certain menus.
- Auto Button (Swirl Icon): Toggles the controller into Auto mode, enabling automatic operation.
- Start Button (Green): Used to start the genset in Manual mode.
- Alarm Indicator: Illuminates to indicate a fault condition.
- LCD Display: Shows genset parameters, fault messages, and menu options.
6. Configuration and Parameter Adjustment
Parameters such as thresholds and delay values can be adjusted to suit specific application requirements. The controller offers two methods for configuration:
- Front Panel: Most parameters can be modified directly using the touch-buttons and LCD display on the front panel.
- PC Software via USB: All parameters can be adjusted using dedicated PC software connected to the controller via the Type-B USB port. This method offers a comprehensive interface for detailed configuration.
All user-defined parameters are saved in internal FLASH storage, ensuring they are retained even after power loss.
7. Maintenance
To ensure optimal performance and longevity of your Smartgen Genset Controller, regular maintenance is recommended:
- Cleaning: Keep the front panel clean and free from dust and debris. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents.
- Connections: Periodically check all wiring connections for tightness and signs of corrosion. Loose connections can lead to intermittent operation or faults.
- Firmware Updates: Check the manufacturer's website for any available firmware updates that may improve performance or add new features.
- Environmental Conditions: Ensure the controller operates within its specified environmental conditions (temperature, humidity) to prevent damage.
8. Troubleshooting
This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact technical support.
- Controller Not Powering On:
- Check battery voltage and connections (B+ and B- terminals).
- Ensure the power supply is within the DC (8~35)V range.
- Genset Fails to Start:
- Verify the controller is in Manual or Auto mode.
- Check fuel level and oil pressure sensor readings.
- Inspect crank output and fuel relay connections.
- Ensure emergency stop input is not active.
- Alarm Indication:
- Check the LCD display for specific fault messages.
- Refer to the genset's manual for corresponding fault codes and troubleshooting steps.
- Verify sensor connections for temperature, oil pressure, and fuel level.
- Incorrect Parameter Readings:
- Ensure sensors are correctly calibrated and wired.
- Check sensor compatibility settings in the controller's configuration.
9. User Tips
Based on general user feedback and product characteristics:
- Always ensure proper grounding for the genset and controller to prevent electrical interference and ensure safety.
- When configuring parameters, make small adjustments and test the system thoroughly before deploying in a critical application.
- Keep a backup of your configuration settings, especially if using PC software for advanced adjustments.
- Regularly monitor the genset's performance data displayed on the LCD to identify potential issues early.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please refer to the documentation provided by your retailer or contact Smartgen directly. Keep your purchase receipt and product serial number handy when contacting support.