Teka 81460133

Contents

Teka Extractor Hood Filter

Model: 81460133 (275mm x 345mm)

Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your Teka Extractor Hood Filter, model 81460133. This filter is designed to capture grease and other airborne particles, ensuring optimal performance of your extractor hood and maintaining a clean kitchen environment. Please read these instructions carefully before use and retain them for future reference.

Safety & Warnings

  • Always disconnect power to the extractor hood before attempting to install, remove, or clean the filter. Failure to do so may result in electric shock.
  • Handle the filter with care, as edges may be sharp. Wear protective gloves if necessary.
  • Ensure the filter is correctly seated and secured in the hood to prevent it from falling during operation.
  • Do not use damaged or bent filters, as this can impair performance and potentially damage the hood.
  • This product is intended solely for use as a replacement grease filter in compatible Teka extractor hoods. Do not use for any other purpose.

Setup & Installation

Follow these steps to install or replace your extractor hood filter:

  1. Disconnect Power: Before starting, ensure the extractor hood is completely disconnected from the main power supply.
  2. Locate Existing Filter: Open the hood's filter housing or release the clips holding the old filter in place.
  3. Remove Old Filter: Carefully remove the old grease filter. Be aware that it may contain accumulated grease.
  4. Prepare New Filter: Unpack the new Teka Extractor Hood Filter (Model 81460133). Inspect it for any damage.
  5. Insert New Filter: Align the new filter with the filter housing. The filter has a handle for easy insertion and removal.
  6. Front view of the Teka Extractor Hood Filter

    Front view of the Teka Extractor Hood Filter

  7. Angled view of the Teka Extractor Hood Filter

    Angled view of the Teka Extractor Hood Filter

  8. Secure Filter: Push the filter firmly into place until it clicks or the retaining clips engage. Ensure it is flush with the hood's surface and securely held.
  9. Restore Power: Once the filter is securely installed, reconnect the extractor hood to the main power supply.
  10. Test Operation: Turn on the extractor hood to ensure it operates correctly and the filter remains in place.

Operating Instructions

The extractor hood filter functions passively to trap grease and cooking odors. No specific operational steps are required for the filter itself beyond proper installation. Ensure your extractor hood is operated according to its own manual for optimal performance and filter effectiveness.

Maintenance

Regular cleaning of your grease filter is crucial for maintaining the efficiency of your extractor hood and preventing fire hazards. The frequency of cleaning depends on your cooking habits.

  • Cleaning: Grease filters can typically be cleaned by hand or in a dishwasher. For hand washing, use hot water and a degreasing detergent. For dishwasher cleaning, place the filter in the dishwasher and run a normal cycle. Avoid using abrasive cleaners or brushes that could damage the filter mesh.
  • Drying: After cleaning, allow the filter to dry completely before re-installing it into the extractor hood.
  • Replacement: While metal grease filters are washable, they may need replacement if they become heavily damaged, deformed, or if their grease-trapping efficiency significantly decreases over time.

Troubleshooting

If you experience issues related to your extractor hood's performance, consider the following:

  • Reduced Airflow/Suction: This is often a sign that the grease filter is saturated and requires cleaning or replacement. A clogged filter restricts airflow.
  • Unpleasant Odors: If odors persist even after cooking, the filter may be saturated with grease and needs cleaning.
  • Filter Not Fitting: Double-check the dimensions of your hood's filter slot against the filter's specifications (275mm x 345mm). Ensure it's inserted correctly and not obstructed.

Specifications

FeatureDetail
Model81460133
Dimensions (Length x Width)275mm x 345mm
ShapeRectangular
MaterialMetal (Aluminum mesh)
CertificationCE
OriginMainland China

For precise measurements, refer to the diagram below:

Dimensional diagram of the Teka Extractor Hood Filter (275mm x 345mm)

Dimensional diagram showing 275mm x 345mm measurements

User Tips

  • Quantity: Please note that this product is typically sold as a single filter unit. If your hood requires multiple filters, ensure you order the appropriate quantity.
  • Compatibility: Always verify the dimensions of your existing filter or hood's filter slot before purchasing to ensure compatibility.

Warranty & Support

For warranty information or technical support, please contact the manufacturer or your retailer. Keep your purchase receipt as proof of purchase.

Manufacturer Information:

  • Manufacturer: Xuzhou Yisheng Trading Co., Ltd
  • Address: China Jiangsu Province Xuzhou Jiawang District Damiao Subdistrict 3-1 Guomao Zhigu Industrial Park, Dada Road
  • Email: anderson811001@aliyun.com

EU Authorized Representative:

  • Representative: TB EC REP EUROPEAN SL
  • Address: Calle Marcelo Usera 60, LC.Spain
  • Email: EUREG@TBVAT.COM

A digital version of the item guide and documents may be available. You can view it here.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.