Daxtromn GGH-3.5KW

Contents

Daxtromn GGH-3.5KW Hybrid Solar Inverter User Manual

Model: GGH-3.5KW | Brand: Daxtromn

1. Introduction

The Daxtromn GGH-3.5KW is a 3500W (3.5KW) pure sine wave hybrid solar inverter designed for 24V systems. It features a built-in 80A MPPT solar charge controller and is capable of operating with or without external batteries. This inverter efficiently converts DC power from solar panels into AC power for household appliances, and can also utilize AC grid or generator power. Its robust design includes a dustproof kit for harsh environments and a mainboard with a waterproof coating for enhanced durability.

Front view of the Daxtromn GGH-3.5KW Hybrid Solar Inverter

Figure 1: Front view of the GGH-3.5KW Hybrid Solar Inverter with its display and control buttons.

2. Product Features

  • Pure sine wave output for sensitive electronics.
  • Integrated 80A MPPT solar charge controller.
  • Maximum 500VDC PV input.
  • Compatible with 24V battery systems.
  • Operates efficiently with or without batteries.
  • Supports 50Hz or 60Hz output (programmable).
  • Ability to utilize AC grid or generator power.
  • Built-in dustproof kit for enhanced durability in challenging environments.
  • Intelligent fan control for power saving and reduced noise at low loads.
  • Mix power function supports hybrid power supply from grid and solar energy.
  • Equipped with Battery Management System (BMS) support.
  • Supports RS232/RS485 communication interfaces.
  • Lithium battery activation function.
  • Dry contact for generator start.
  • Mainboard features a waterproof coating for moisture and corrosion resistance.
  • MOSFET pin protection to prevent short circuits from foreign objects.
  • Internal large wire diameter for reduced heat generation.

3. Setup and Installation

Before installation, ensure the inverter is placed in a well-ventilated area, away from direct sunlight, heat sources, and moisture. Refer to the following diagrams for physical dimensions and interface identification.

Side view of the Daxtromn GGH-3.5KW Hybrid Solar InverterRear view of the Daxtromn GGH-3.5KW Hybrid Solar Inverter showing connection ports

Figure 2: Side and Rear views of the inverter, highlighting ventilation and connection points.

3.1 Interface Description

Diagram showing structure size and numbered interface descriptions for the inverter

Figure 3: Inverter structure and interface description.

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function buttons
  6. Power on/off switch
  7. AC input
  8. AC output
  9. Battery input
  10. PV input
  11. Circuit breaker
  12. Dry contact
  13. Parallel communication port (Not Supported on this model)
  14. BMS communication port
  15. RS232 communication port

3.2 System Connection Diagram

The following diagram illustrates a typical system setup, connecting the inverter to solar panels, battery packs, utility grid or generator, and household appliances.

System connection diagram for the hybrid solar inverter, showing solar panels, battery, utility/generator, and home appliances

Figure 4: Hybrid Solar Inverter System Diagram.

Important Note for PV Input:

  • If the solar inverter is used without an external battery, the voltage connected to the solar panel must be above 150VDC for normal operation.
  • If an external battery is connected, the inverter will operate with a solar panel input voltage of 120VDC or higher.

4. Operating Instructions

The GGH-3.5KW inverter is designed for flexible power management. It can prioritize solar power, battery power, or AC utility/generator power based on user settings (refer to the detailed programming section in the full manual, if available). The LCD display (1) provides real-time status, while the status (2), charging (3), and fault (4) indicators offer quick visual feedback. Use the function buttons (5) to navigate menus and adjust settings.

The inverter supports both 50Hz and 60Hz output frequencies, which can be programmed according to regional requirements. Its "Mix Power" feature allows for a hybrid power supply from both the grid and solar energy, optimizing energy usage and minimizing waste.

The intelligent fan system adjusts its speed based on the load, reducing noise and saving power during periods of low or no load.

5. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. The unit is designed with several features to minimize maintenance needs:

  • Dustproof Kit: The built-in dustproof kit helps protect internal components from dust accumulation, which can affect performance and lifespan. Periodically inspect the air vents and clean if necessary to ensure proper airflow.
  • Mainboard Protection: The mainboard is treated with a waterproof coating, offering resistance against moisture and corrosion. This enhances durability, especially in humid environments.
  • MOSFET Pin Protection: This feature prevents small insects or debris from causing short circuits, contributing to the inverter's reliability.
  • Battery Management System (BMS): The inverter supports external BMS communication, which simplifies the management and maintenance of compatible lithium battery systems.

For detailed cleaning procedures and component checks, consult the comprehensive product manual.

6. Troubleshooting

This section provides guidance on common issues. For complex problems, contact technical support.

  • Inverter not starting or no output:
    • Check the power on/off switch (6) is in the 'ON' position.
    • Verify AC input (7) and battery input (9) connections are secure and providing correct voltage.
    • Ensure PV input voltage (10) meets the minimum requirements: above 150VDC without battery, or above 120VDC with an external battery.
    • Check the circuit breaker (11) for trips.
    • Observe the Fault indicator (4) for error codes on the LCD display (1).
  • Low or no solar charging:
    • Confirm solar panels are clean and unobstructed.
    • Verify PV input voltage (10) is within the MPPT range (120-450VDC).
    • Check the Charging indicator (3).
  • Unusual noise:
    • The intelligent fan adjusts speed based on load; higher loads may result in increased fan noise. If noise is excessive at low loads, ensure proper ventilation and check for obstructions.

7. Specifications

Detailed technical specifications for the GGH-3.5KW Hybrid Solar Inverter:

Detailed specifications table for GGH-3.5KW and GGH-6.5KVA hybrid solar inverters

Figure 5: Technical Specifications.

ParameterValue (GGH-3.5KW)
ModelGGH-3.5KW
Rated Power3500VA/3500W
Parallel CapabilityNo
Work without BatteryYes
INPUT (AC)
Voltage230VAC
Optional Voltage Range170-280VAC (For Personal Computers), 90-280VAC (For Home Appliances)
Frequency Range50Hz/60Hz (Auto Sensing)
OUTPUT (AC)
AC Stabilized Voltage230VAC ± 5%
Surge Power7000VA
Peak efficiency93.50%
Switching time10ms (For Personal Computers); 20ms (For Home Appliances)
Wave formPure Sine Wave
BATTERY
Battery voltage range21-30V
Charging curveThree-Stage
Lithium battery charging strategyAdaptive to lithium battery
Solar Charge & AC Charge
Maximum photovoltaic power3500W
Maximum PV open circuit voltage500VDC
MPPT Range & Working Voltage120-450VDC
Maximum Solar Charging Current80A
Maximum AC charging current60A
Solar Charger TypeMPPT
General Data
Product size (mm)302*490*110mm
Net Weight (kgs)8.44kgs
Communication InterfaceRS232/RS485CAN /Drycontact
Relative Humidity5% to 95%
Operating Temperature-10°C to 50°C
Storage Temperature-15°C to 60°C
Is Smart DeviceYes
CertificationCE

8. Warranty and Support

The Daxtromn GGH-3.5KW Hybrid Solar Inverter comes with a 1-year warranty from the date of purchase. For warranty claims or technical assistance, please contact your vendor or the manufacturer directly.

The inverter includes communication interfaces such as RS232, RS485CAN, and Dry Contact for monitoring and control. It also features a dedicated BMS communication port for integration with compatible battery systems (e.g., PYLON or PACE protocol).

An optional WiFi module is available for remote monitoring and control. If you require this functionality, please inquire with your seller for purchase details.

9. User Tips

  • PV Input Voltage: Always ensure your solar panel array voltage meets the minimum requirements for the inverter to operate correctly. Remember, 150VDC minimum without a battery, and 120VDC minimum with an external battery.
  • Battery Compatibility: This inverter supports various battery types including Lithium, Lead-Acid, and Gel batteries. Ensure your battery system is compatible and correctly configured.
  • Optional WiFi: For convenient remote monitoring and management of your inverter, consider purchasing the optional WiFi module. Contact your supplier for more information.
  • Efficient Energy Use: Utilize the "Mix Power" feature to combine grid and solar energy, ensuring no electricity is wasted and optimizing your energy consumption.
  • Quiet Operation: The intelligent fan system is designed to reduce noise at low loads. For optimal quietness, ensure the inverter is not under heavy load when noise is a concern.
Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.