EASUN POWER IGrid-SV-IV-5.6KW

EASUN 5.6KW 48V Hybrid Solar Inverter

Model: IGrid-SV-IV-5.6KW

User Instruction Manual

1. Introduction

This manual provides essential information for the installation, operation, and maintenance of your EASUN 5.6KW 48V Hybrid Solar Inverter. Please read this manual thoroughly before installation and operation to ensure proper and safe usage of the device. This hybrid inverter is designed to efficiently manage power from solar panels, batteries, and the utility grid, providing a reliable power supply for your home or business.

Video: Overview of the EASUN 5.6KW Hybrid Solar Inverter.

2. Main Features

  • Customizable status LED ring with RGB lights for visual feedback.
  • Touchable button interface with a 4.3-inch colored LCD for easy configuration and monitoring.
  • Supports USB On-the-Go (OTG) function for data transfer.
  • Internal storage for data log events.
  • Enables self-consumption and feed-in to the grid.
  • Programmable supply priority for PV, Battery, or Grid sources.
  • User-adjustable charging current and voltage settings.
  • Multiple programmable operation modes: Grid-tie, off-grid, and grid-tie with backup.
  • Built-in WiFi for convenient mobile monitoring via a dedicated application.
  • Reserved communication port for Battery Management System (BMS) integration.
  • Supports parallel operation of up to 9 units for increased capacity.
Hybrid 5.6KW Solar Inverter features and icons

Image: Key features of the EASUN 5.6KW Hybrid Solar Inverter.

3. Package Contents

Upon unpacking, please verify that all items listed below are included and undamaged:

  • EASUN 5.6KW Hybrid Solar Inverter Unit
  • User Manual
  • Software CD
  • USB Communication Cable
Package contents of the EASUN 5.6KW Hybrid Solar Inverter

Image: Contents included in the product package.

4. Technical Specifications

Detailed technical specifications for the EASUN 5.6KW Hybrid Solar Inverter

Image: Detailed technical specifications table.

EASUN IGrid SV IV 5.6KW Hybrid Solar Inverter Specifications
ParameterValue
ModelIGrid SV IV 5.6KW
Rated Output Power5600W
Max. PV Input Power6000W
Max. Charging Power6000W
GRID-TIE OPERATION - PV Input (DC)
Nominal DC Voltage360VDC/450VDC
Max. DC Voltage450VDC
Start-up Voltage / Initial Feeding Voltage110VDC/120VDC
MPPT Voltage Range120VDC~430VDC
Number of MPPT Trackers / Max. Input Current1/27A
GRID-TIE OPERATION - Grid Output (AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range184-264.5VAC or 195.5-253VAC (Selectable)
Nominal Output Current24.3A
Power Factor>0.9
EFFICIENCY
Max. Conversion Efficiency (DC/AC)96%
OFF-GRID OPERATION - AC Input
AC Start-up Voltage / Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Max. AC Input Current40A
OFF-GRID OPERATION - PV Input (DC)
Max. DC Voltage450VDC
MPPT Voltage Range120VDC~430VDC
Number of MPPT Trackers / Max. Input Current1/27A
BATTERY MODE OUTPUT (AC)
Nominal Output Voltage220/230/240VAC
Output WaveformPure Sine Wave
Efficiency (DC to AC)93%
HYBRID OPERATION - PV Input (DC)
Nominal DC Voltage360VDC/450VDC
Max. DC Voltage450VDC
Start-up Voltage / Initial Feeding Voltage110VDC/120VDC
MPPT Voltage Range120VDC~430VDC
Number of MPPT Trackers / Max. Input Current1/27A
HYBRID OPERATION - Grid Output (AC)
Nominal Output Voltage220/230/240VAC
Output Voltage Range184-264.5VAC or 195.5-253VAC (Selectable)
Nominal Output Current24.3A
HYBRID OPERATION - AC Input
AC Start-up Voltage / Auto Restart Voltage120-140VAC/180VAC
Acceptable Input Voltage Range90-280VAC or 170-280VAC
Max. AC Input Current40A
BATTERY & CHARGER
Nominal DC Voltage48VDC
Max. Solar Charging Current120A
Max. AC Charging Current120A
Max. Charging Current120A
GENERAL PHYSICAL
Dimension (D*W*H)140*295*468 mm
Net Weight12 kg

5. Installation and Setup

Before proceeding with installation, ensure the inverter is placed in a well-ventilated area, away from direct sunlight, heat sources, and moisture. All electrical connections must be performed by qualified personnel in accordance with local electrical codes.

5.1. System Diagram

System diagrams for inverter operation with and without battery connected

Image: System diagrams illustrating operation with and without battery connected.

5.2. PV Connection

When connecting PV modules, observe the following parameters:

  • The Open Circuit Voltage (Voc) of PV modules must not exceed the maximum PV array open circuit voltage of the inverter.
  • The Open Circuit Voltage (Voc) of PV modules should be higher than the minimum battery voltage.
Diagram illustrating PV panel connection to the inverter with PV module parameters

Image: PV Panel connection diagram and recommended PV module parameters.

5.3. Battery Connection

The IGrid SV IV 5.6KW model supports a 48VDC battery system. Ensure batteries are connected in series to achieve the required voltage, maintaining correct polarity.

Diagram showing battery connection to the inverter (four 12V batteries in series)

Image: Example of connecting four 12V batteries in series for a 48V system.

5.4. Rear Panel Connections

Familiarize yourself with the rear panel connections for AC input/output, DC input, PV input, and communication ports.

Detailed view of the inverter's rear panel with labeled AC input/output, DC input, PV input, and communication ports

Image: Labeled rear panel connections.

5.5. Parallel Function

The inverter supports parallel operation of up to 9 units for single-phase or 3-phase configurations. Refer to the diagrams for proper power connections.

Diagrams illustrating parallel operation in single-phase and 3-phase configurations for up to nine inverters

Image: Parallel operation diagrams for single and three-phase systems.

6. Operation

6.1. Display and Touch Keys

The inverter features a 4.3-inch colored LCD with touch-sensitive buttons and a customizable RGB LED ring for status indication.

Product overview image with dimensions and a table describing touch screen function keys

Image: Product overview with dimensions and touch key functions.

Touchable Function Keys
Function KeyDescription
ESC (Return/Exit)To exit the current setting or menu.
Up Arrow (▲)To access USB setting mode or navigate up in menus.
Down Arrow (▼)To move to the last selection or navigate down in menus.
Enter (↵)To confirm or enter the selection in setting mode.
Close-up of the inverter's touch screen display with RGB LED ring

Image: Inverter display showing operational data and touch controls.

6.2. Operation Modes

The inverter supports various programmable operation modes:

  • Grid-tie: Feeds excess solar power back to the utility grid.
  • Off-grid: Operates independently from the utility grid, typically using battery storage and solar power.
  • Grid-tie with backup: Combines grid-tie functionality with battery backup for uninterrupted power during outages.

Refer to the detailed manual (on CD) for specific programming instructions for each mode.

6.3. RGB LED Ring Customization

The inverter's RGB LED ring can be customized to display various colors, providing visual cues for operational status or personal preference.

Image showing various RGB LED ring colors

Image: Examples of customizable RGB LED ring colors.

7. Communication

The inverter offers multiple communication options for monitoring and control:

  • USB: For direct connection to a PC for monitoring and configuration.
  • RS-232: Serial communication port for PC connection.
  • BMS Communication Port: Supports CAN, RS-485, or RS-232 for integration with Battery Management Systems.
  • Dry Contact: For external control signals.
  • Built-in WiFi: Enables remote monitoring via a mobile application.
Communication connection diagram showing PC, Inverter, and Battery connections

Image: Communication connections for PC and BMS.

8. Maintenance

Regular maintenance ensures the longevity and optimal performance of your inverter. Always disconnect all power sources before performing any maintenance.

  • Cleaning: Periodically clean the inverter's exterior and ventilation openings to prevent dust buildup, which can affect cooling. Use a dry, soft cloth.
  • Connections: Annually check all electrical connections (PV, battery, AC input/output) for tightness and signs of corrosion.
  • Environment: Ensure the installation environment remains within specified temperature and humidity ranges.
  • Firmware Updates: Check the manufacturer's website for any available firmware updates to improve performance or add features.

9. Troubleshooting

If you encounter issues with your inverter, consult the following general troubleshooting steps. For detailed error codes and solutions, refer to the comprehensive user manual provided on the software CD.

  • No Power/Display: Check all power connections (AC input, battery, PV input) and ensure the power switch is in the 'ON' position. Verify circuit breakers are not tripped.
  • Low Output Power: Inspect PV panel connections and ensure they are clean and free from shading. Check battery voltage and health.
  • Inverter Overheating: Ensure adequate ventilation around the unit. Clear any obstructions from the air vents. Reduce load if consistently overheating.
  • Communication Issues: Verify USB/Ethernet cable connections. Ensure WiFi settings are correctly configured and the mobile app is updated.
  • Error Codes: Note any error codes displayed on the LCD and consult the detailed manual for specific diagnostic steps.

10. User Tips

  • For optimal battery life, ensure your battery charging parameters are correctly set according to your battery type (e.g., LiFePO4, Lead-Acid).
  • Regularly monitor your system's performance via the mobile app to identify any anomalies early.
  • When configuring parallel units, ensure all inverters are of the same model and firmware version for stable operation.

11. Warranty and Support

For warranty information, technical support, or service requests, please contact your authorized dealer or the EASUN POWER customer service. Keep your purchase receipt and product serial number handy for faster service.

Related Documents - IGrid-SV-IV-5.6KW

Preview EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage - Technical Specifications
Detailed technical specifications and selection guide for the EASUN POWER IGrid SV II 6KW On-Grid Inverter with Energy Storage. Features include pure sine wave output, hybrid operation modes, and parallel capabilities.
Preview EASUN POWER Hybrid 3.6KW/5.6KW Inverter/Charger User Manual
Comprehensive user manual for the EASUN POWER Hybrid 3.6KW and 5.6KW Inverter/Charger, detailing installation, operation, safety, specifications, troubleshooting, and advanced features like parallel function and Wi-Fi connectivity.
Preview Easun Power: Comprehensive Solar Solutions and Inverters
Explore Easun Power's extensive range of high-quality solar inverters, charge controllers, batteries, and solar panels designed for residential and commercial applications. Discover innovative energy solutions for a sustainable future.
Preview Easun Power Solar Inverters, Charge Controllers, and Batteries Product Catalog
Explore Easun Power's comprehensive range of solar energy solutions, including high-efficiency solar inverters (off-grid, hybrid, on-grid), MPPT and PWM solar charge controllers, and advanced battery storage systems. Learn about product specifications, applications, and company history.
Preview EASUN IGRID-VX-IV-5.6KW-WIFI All-in-one Solar Charge Inverter User Manual
This user manual provides comprehensive safety, installation, and operating instructions for the EASUN IGRID-VX-IV-5.6KW-WIFI all-in-one solar charge inverter, detailing its features, system integration, and technical specifications for optimal energy management.
Preview Easun Power ISolar SMG II 6.2KP Hybrid Solar Inverter/Charger User Manual
Comprehensive user manual for the Easun Power ISolar SMG II 6.2KP (6.2KVA 230Vac) hybrid solar inverter/charger, covering installation, operation, specifications, and troubleshooting for reliable power solutions.